FUNCTION
Basic 4 Channels and added 6 Channels.
6 Channel is as below.
1. LED : ON / OFF
-> CH8 1100us / 1900us
2. 2.4GHz Mz-4 spec.
Frequency band 2400MHz ~2483.5 MHz
Modulation FHSS
Transmission output about 1mW
Temperature range -10 … +55 ℃
Antenna Monopole Antenna
Battery AAA Size x 3 pcs
Operating voltage 3.6 … 4.8V
Output voltage about 50mA
Dimension 151 x 134 x 63.7 mm
Weight about 260g (Incl. battery)
Main function and Channel
P2
Transmitter manual
Operating transmitter
- Power on : Pull Slide switch up
- Power off : Pull Slide switch down

1)Attitude Function
hen you push Function button, one short sound rings.
control of general quad copters.
hen you push Function button, two short sound rings.
ou can do rotation and normal flight on 3D flight mode
transmitter. Function is same with 3D helicopter
W
This function is attitude
2) Rate Function
W
Y
with
Trim Button
.
Power SW
Status & Function

P3
When the lights are on, LED stay ON condition.
blinks with one second intervals.
and Transmitter status function.
nd, LED blinks with 0.5 second
LED Function
1) LIGHT ON / OFF Function
Yellow Led
① When the lights are off, LED
②
(default status)
2) SPEED Attitude and Rate Function
Red Led
① Attitude mode : LED
status)
② Rate mode : LED
3) Binding
Red Led (Status Led
① Show Power and Binding
② If device is not bou
intervals.
③ If device is bound, LED stay ON
condition.
(default
.
Status Discription
Bind status (No
bind)
Bind Success,
Bind range
RX receive OK
Range Test
Low Voltage
Sensor Warring
Rx Voltage,
Error
Normal mode
Program
mode
Temp Error
Receive rate low,
No RX
Factory Error
Trim inc/dec
Trim 0%
Program mode
start
Program mode
exit
Servo Reverse
(Normal)
Servo Reverse
(Reverse)
ATV 100%
Fail Safe mode
start
Fail safe (trim dn,
hold)
Fail safe (trim up,
fail)
Green LED Buzzer
on
on
1 blink
(5times)
2 blink
(5times)
1 blink
(5times)
2 blink
(5times)
low beep(1)
low beep(2)
low beep(2)
High beep(4)
High beep(3)
High beep(2)
High beep(1)
Low beep(1)
low beep(1)
High beep(1)
low beep(1)
low beep(1)
low beep(1)
low beep(2)
High beep(1)
low beep(2)
low beep(1)
High beep(1)
/2sec
/2sec
/2sec
/2sec
/2sec
/2sec
/click
/click
Stick
Calibration
Calibration mode
start
Stick move done
Dead range set
3 blink
(3times)
Dead
blink/3sec
low beep(2)

P4
he last used memory will be bound
In case of No Receiver connection, if you press the
is not searched, it will be repeated until
Receiver, and you can bind with new Receiver by
In case of no having receiver, which is already saved in
memory, then you can bind with new receiver by
If Receive Signal is normal, RED LED will be turned On.
In case of Waiting Receiver or Range warning, RED
eceiver, if you shortly press this
functional Switch, Range Test mode will operate for
While operating Range mode, if you shortly press this
t Range mode operation, RED LED will blink quickly
Warning will be announced and at
While Binding, Transmitter should always have distance
from the Receiver. At least 1m should have.
workable only at Binding condition
Condition of Basic Operation
Release Program mode : Press two Stick Switch
once per a second interval
Stick Calibration, Default will
value, Customer can adjust trim as below
f move to 100% position, High Beep
Red Led will be blinked once per a second interval
once per a second interval
when change Servo direction.
ll sticks are on neutral pos
f press Power switch with pressed trim switch to Max. or
Min. position, Normal mode and Reverse mode will be
blinked once per a second interval
Green LED will be blinked once per a
Program Mode
(
)
Normal Mode
(1) Basic Operation
- When Power on, t
Receiver.
-
button of left stick for 1sec,
- if Receiver
pressing BIND/LED Switch.
(2) BIND mode
pressing BIND Switch.
LED will be slow blinked.
(3) Range Test mode
Functional switch:
SNAP once.
After Binding with R
to
find
SPEED +
(1)
Enter to Program mode
simultaneously for 2sec.
simultaneously
Indication of
once per a second interval
.
Program mode : Blink
(2) Saving Data
50pcs of last used
(3) Adjustment of
In case of
- 100% --
At Max. or Min. Positi
Range of Trim is available
I
occurred once.
-
: Press two Stick Switch
will be blinked
Position
be 100%. At this
way.
adjust Trim Switch
.
sound will be
90sec.
switch, Range test mode will be ended.
A
and make buzzer sound.
After 90sec, Beep sound will be
enter to Main Mode.
(4) Low Battery Voltage warning
RED LED will do fast blinking. (
At under 3200V,
3300V, warning will be removed.
3Cell Alkaline Battery will be used.
Important Point :
Otherwise, it might be connected to
do malfunction.
one time, and
Program mode : Blink
(4) Servo Reverse Set
This is used
A
switch to Max. or Min. Posi
I
changed.
- Indication of Servo Rece
- Normal mode :
second interval.
ition, and move the trim
ver mode : Red Led will be

P5
Green LED will be blinked
once per a second interval
once per a second interval
Reverse mode : Blink twice per a second interval
stick switch for a second at Program mode.
per channels and select Fail pos mode
stick switch for a second, Fail safe setting
If Trim is UP, it is a Fail safe mode, and
ce per a second interval.
Green LED will be blinked once per a second interval.
once per a second interval (
Blink twice per a second interval (
f enter to Mode, RED LED will blink 3 times.
: Blink 3 times per a second
Move all sticks from side to Side and back
fter operated last stick, hold it to middle position for
Red and Green LED will blink 3Times at
Blink 3 Times per a second interval
after that, it is moved to Dead Range set mode
Dead range set about Neutral position, is set by trim
, there is no spring, Do not set.
only set for CH2, CH3, CH4
Green LED will blink depends on Neutral set steps.
or example, if you set Dead range to 6%, LED will
Blink 3times per a sec interval.
Blinks depends of setting value
f set is done, press left stick button for 2 sec.
How to do Stick Calibration
-Reverse mode :
second interval.
Program mode : Blink
Normal mode : Blink
(Repetition 5times)
(Repetition 5times)
(5) Fail Safe Set
Press right
Press trim button
and Hold it.
Whenever press Trim button, Setting-
transferred to Receiver.
twice per a
(1) Enter to Stick
Turn On the Radio
I
Stick calibration mode
interval
(2) Set Stick Calibration
position.
A
3Seconds.
If Set is done,
same time.
Stick calibration mode
pressing left stick switch.
to middle
Stick move done
If press right-
mode will be ended.
- Indication of Fail Safe mode : RED
twice per a second interval.
- Pos mode :
Green LED will be blinked twi
(Repetition 5times)
- Hold mode : If Trim is Down, it is a
(Repetition 5times)
Program mode (Failsafe mode):
second interval
Hold mode : Blink
Hold mode, and
Repetition
※
automatically.
(3) Dead range set
This is for keep Neutral
accurate Neutral value.
switch up and down.
It can be settable
※ in case of Throttle CH1
(
F
blink 4time
Dead range mode
, in case of they have no
( 0, 2, 4, 6, 8, 10% )
)
5times)
Pos mode :
5times)
Repetition
Dead range set
I
(6 steps)

P6
안안안안
(1) KC 인증
Graupner mz-8 Transmitter
KCC
인인인인
: MSIP-CRM-sjr-16006700
(2)
Conformite Europeenne
Product(s): Graupner mz-8 Transmitter,
(3) FCC Information
Graupner mz-8 Transmitter
FCC ID: SNL-16006700
FCC Statement
1. This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including
interference that may cause undesired operation.
2. Changes or modifications not expressly approved by the party
responsible for compliance could void the user‘s authority to operate
the equipment.
• NOTE
This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- _Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
• FCC radiation exposure statement
This equipment complies with FCC radiation exposure limits set forth
for an uncontrolled environment.
◎
Notes on environmental protection
This symbol on the product, user
manual or packaging indicates that this
product must not be disposed of with
other household waste at the end of its
life. It must be handed over
to the applicable collection point for the
recycling of electrical and electronic
equipment.
The materials are recyclable as marked. By recycling,
material reusing or other forms of scrap usage you are
making an important contribution to environmental
protection.
Batteries and accumulators must be removed from the
device and disposed of at an appropriate collection point.
Please inquire if necessary from the local authority for
the appropriate disposal site.