It has a balanced flue system which takes air for combustion from the outside and discharges products of combustion to the
outside. It must be mounted on an external wall and can stand on a non-combustible hearth or suitable fire surround (rated at
150°C). There are two heat settings operated by turning the control knob which is located at the bottom left hand side of the fire
behind the fender ash-pan. The burner system is designed to give various flame effects at the respective heat settings.
The ignition is by combined piezo which operates by turning the control knob to the ignition position to light the pilot. It has a
thermo electric flame supervision device for safety. Use only the coals supplied with this fire. Do not use any other material or burn
any rubbish on the fire. Do not use the fire with a broken or damaged fuel bed or with a broken or cracked glass.
IMPORTANT NOTES
2. The fire must be installed and serviced regularly, in accordance with the installation/servicing instructions, the rules in force
and Gas Safety (Installation and Use) Regulations, by a competent person e.g. British Gas or a CORGI member.
3. The glass door becomes hot when the fire is in use and must not be touched. The glass door conforms with the requirements
of BS 1945 : 1991 and satisfies the Heating Appliances (Fireguards) (Safety) Regulations 1991. The door is to prevent risk of
fire or injury from burns and it shall not be permanently removed or the fire used without it fitted.
IT DOES NOT GIVE FUll PROTECTION FOR YOUNG CHilDREN, THE INFIRM OR THE ELDERLY.
Extra security can be provided by fitting a fireguard which complies with BS 6539 : 1984 (fireguards suitable for use with
solid fuel appliances) or BS 6778 (fireguards for use with portable, free-standing or wall mounted appliances).
WARNING: The glass is of a special heat resisting type, and if damaged must be replaced with the proper spare.
5. After the fire has been installed you may wish to fix a shelf of combustible material above. This is quite acceptable provided
the dimensions comply with the diagram shown in the Installation Instructions. The specification of materials used in
'Surrounds', other than marble and wood, must be checked to confirm satisfactory performance.
8. Clothes etc. must not be draped overthe fire. Curtains must be 230mm (9in) clear at the top of the heater and 150mm (6in)
at the sides, and must not be closeable over the front of the heater.
9. "Soft furnishings" such as blown vinyl wallpaper are easily affected by heat and may become discoloured if fitted close to a
heating appliance. Please bear this in mind when installing a fire and when redecorating.
58083