GRATE GLOW 32 329 99, Mayfair, 32 329 23, Chelsea, Plmllco User Instructions

...
THE GAS CONSUMERS' COUNCIL
(GCC) IS AN INDEPENDENT
ORGANISATION WHICH PROTECTS
THE INTEREST OF GAS USERS.
IF YOU NEED ADVICE, YOU WILL
FIND THE TELEPHONE NUMBER IN
YOUR LOCAL TELEPHONE
GrateGlow
A CARVER GROUP COMPANY
--..--.........
THE ALL NEW
CAPITAL COLLECTION
Cat II
2H3P
G20 at 20mbar convertible to G31 at 37mbar.
For use in GB and lE.
Users Instructions
THIS LEAFLET IS INTENDED TO HELP YOU UNDERSTAND AND USE YOUR NEW FIRE EFFICIENTlY.
PLEASE READ THESE INSTRUCTIONS BEFORE USING THE FIRE AND KEEP FOR FUTURE REFERENCE,
5'7985
TRIMS
New Plmllco - GC No. 32 329 23
Available In BlacklBrass effect
New Chelsea - GC No. 32 329 24
Available In Black/Chrome effect
New Mayfair - GC No. 32 329 99 Available in BlacklBrass effect or Black/Chrome effect
57985
IMPORTANT NOTES
1. The appliance name and serial number are on the data badge which is located on the left hand side of the fire base panel. Remove the fender and ash-pan cover for access to read the data badge. (See Figs 1and 2).
3. This fire must be installed and serviced regularly in accordance with the Gas Safety (Installation and Use) Regulations and the rules in force by a competent person e.g. British Gas or CORGI member. Where solid fuel has been used the chimney must be swept before installation. This fire must be installed in accordance with the installation instructions.
4. It is recommended that at least once a year the appliance should be removed to check the catchment space and the chimney for debris. The fire should be checked annually to ensure continued clearance of combustion products and that there is no excessive
build up of soot.
5. WARNING: This fire has a naked flame. Also certain parts, especially the canopy, will be hot when in use. A fireguard conforming to
B.S. 6539 (Fireguards for use with solid fuel appliances) should be used for the protection of children, the elderly or the infirm. Such a guard is also recommended for pet animals.
6. After the fire is installed you may wish to fix a shelf above. This is quite acceptable provided that the underside of the shelf is at least 237mm above the fire and does not project more than 150mm forward. For a deeper shelf allow 13mm increase in shelf height for
every 25mm increase in shelf depth.
8. When the fire is first used it may give off some slight smoke and smell but these will soon clear after a few hours of use at the HIGH
setting.
10. IMPORTANT: When considering fitting any heating appliance or wallpapering a room in which one is fitted, if blown vinyl or other heat sensitive wallpapers are used in the vicinity of the heat source, then they may become heat damaged or discoloured especially just above the fire.
11. It is important for safe operation and to maintain efficiency that the fire is not operated with damaged or broken coals. IMPORTANT NOTE: Under no circumstances should extra coals be used together with the existing coals.
ONLYTHE CORRECT COALS SHOULD BE USED.
12. If purpose built ventilation is provided for the fire, it should be checked periodically to ensure that it is free from obstruction.
On pre-cast flue installations the walls must be dry lined over the route of the flue. Dry lining is the use of
plasterboard with an air space between the wall and the
plaster board. Installation must not be made into pre-cast flues that have plaster applied directly to the surface of the wall i.e. wet lined, because experience has shown that in
some wet lined installations the lack of heat insulation
provided by plaster can cause the plaster to shrink or crack
and other decoration such as wallpaper to discolour or
detatch from the wall.
14. This product uses fuel effect pieces containing Refractory Ceramic Fibre (RC F), which are man-made vitreous silicate
fibres. Excessive exposure to these materials may cause temporary irritation to eyes skin and respiratory tract,
consequently, it makes sense to take care when handling
these articles to ensure that the release of dust is kept to a
minimum.
5 8
.....
l:
a
Loading...
+ 7 hidden pages