This document may not be copied, in whole or in part, or otherwise reproduced, except as specifically
permitted under U.S. copyright law, without the prior written consent of Grass Valley Group, P.O. Box
599000, Nevada City, CA 95959-7900 USA. GRASS VALLEY GROUP is a registered trademark and
Grass Valley is a trademark of Grass Valley Group. All registered trademarks and trademarks are property of their respective holders. Grass Valley Group products are covered by U.S. and foreign patents,
issued and pending. Product options and specifications subject to change without notice. The information in this manual is furnished for informational use only, is subject to change without notice, and
should not be construed as a commitment by Grass Valley Group. Grass Valley Group assumes no responsibility or liability for any errors or inaccuracies that may appear in this publication.
This manual describes the features of a specific module of the 8900 Series
Distribution Amplifier family. As part of this module family, it is subject to
Safety and Regulatory Compliance described in the 8900 Series frame and
power supply documentation (see the
8900 Series User’s Guide).
8911 Instruction Manualv
Preface
vi8911 Instruction Manual
8911 AES/EBU Reclocking
Distribution Amplifier
Introduction
The 8911 module is a digital audio 1x8 distribution amplifier that provides
reclocking of the digital signal. The amount of digital audio is ever
increasing as studios and broadcast facilities transition to digital transmission. The 8911 offers a low cost method of reclocking AES/EBU digital
audio signals. Reclocking reduces the signal jitter resulting from numerous
passes through other equipment such as audio routers and switchers. The
8911 fits into the 8900 series frames which offer passive loop-through
inputs, high density and a wide range of distribution and format conversion functions.
The 8900 Series product line is a family of serial digital distribution amplifiers (DAs) and signal processors that reside in a 2 rack unit frame which
accommodates up to ten modules. A variety of modules are available that
can provide fanout, timing/reclocking, monitoring, or error detection and
handling capabilities. Modules are selected by the user to suit their particular requirements.
The 8911 distribution amplifier provides:
■
Signal reclocking to reduce jitter,
■
Support of 32, 44.1 and 48 KHz sample rates,
■
Eight outputs for ample distribution,
■
Loop-through input enabling redundant system design,
■
Accepts input cable lengths of up to 1000m (Belden 8281 or equivalent),
and
■
Ten module capacity in a 2 rack unit 8900 frame.
8911 Instruction Manual1
8911 AES/EBU Reclocking Distribution Amplifier
Functional Description
The 8911 has one loop-through, high impedance input and produces eight
75-Ohm outputs. The AES/EBU data is reclocked by means of a phaselocked-loop. Refer to Figure 1 while reading the following description.
AES Input
Loop-through
T1
Differential
Line Rx
Reclocker
AES
Outputs
Output
Line Driver
Input Section
Phase
Input Section
AES/EBU Receiver
U3
Figure 1. 8911 AES/EBU Reclocking DA Block Diagram
Locked
Loop
Lock LED
Output
Line Driver
0544_00
Output Section U4
The input channel is loop-through and is not terminated (the differential
input is high impedance). The input signal comes from the 50-pin connector, P1, and feeds a transformer, T1. Transformer coupling on the input
eliminates common mode noise. The output side of the transformer feeds
the differential line receiver of AES/EBU receiver U3.
The AES/EBU receiver reclocks the data for its AES/EBU data stream. The
mode pins 17, 18, 23 and 24 are set to pass the entire AES3 signal with the
preamble. The receiver has an incoming audio sample frequency range of
25 KHz to 55 KHz.
Output Section
After it is reclocked, the serial data is routed to a quad EIA-485 line driver,
U4. The line driver chip drives eight output lines.
28911 Instruction Manual
Linear Regulator
Specifications
Specifications
The outputs feed a resistive network that performs three functions:
■
Attenuates the signal to become 1 volt peak-to-peak,
■
Creates a 75Ω output resistance matching the cable impedance, and
■
Limits the rise and fall times to meet the AES/EBU specification.
The voltage regulator is a monolithic integrated circuit with a fixed voltage
output of +5 volts. This regulator employs internal current limiting and
thermal shutdown.
Table 1. 8911 Specifications
ParameterValue
Input
Number1 loopthrough
Signal typeAES/EBU digital audio, per AES3id:1995 and SMPTE 276M
Connector 75
Return loss>25 dB, 0.1 to 6 MHz
Outputs
Number8 reclocked
Signal typeAES/EBU digital audio, per AES3id:1995 and SMPTE 276M
Connector 75
Return loss>25 dB, 0.1 to 6 MHz
Performance
Sample Rates48KHz, 44.1KHz, and 32KHz (Automatic selection)
Environmental
Operating temperature range0 to 45° C, noncondensing
Non-operating temperature range-10 to +70° C, noncondensing
Power Requirements
Supply Voltage+12 Volts
Power dissipation3 Watts
Physical
FrameResides in standard 2 rack unit 8900 Series frame
Ω BNC
Ω BNC
8911 Instruction Manual3
8911 AES/EBU Reclocking Distribution Amplifier
Module Installation
There are ten cell locations in the frame to accommodate either analog or
digital modules. These are the left ten slots. Refer to Figure 2.
The two cells on the right are allocated for the power supplies. For additional information concerning the Power Supply module, refer to the
Power Supply manual.
The third cell from the right is allocated for the Controller module. This
module provides the interface for the forced air cover, as well as the SMPTE
269M fault reporting (health alarm). For additional information concerning
the Controller module, refer to the Controller manual.
Any 8900 Module
Controller
Module
(only)
Figure 2. 8900 Series Frame
Power
Supplies
(only)
To install a module into the frame, follow these steps:
1.
Insert the module into the frame, connector end first, with component
side of the module facing to the right and ejector tab to the top.
2.
Verify that the module connector seats properly against the backplane.
3.
Press the ejector tab in to seat the module in place.
0515_04
48911 Instruction Manual
Cabling
Ω
J2
J4
J6
J8
J1
J9 J10
IN
Eight Outputs
Reclocked
DA1
O
U
T
J3
J5
J7
J2
J4
J6
J8
0544_03
Loopthrough
Input
Cabling
8900 module are interchangeable within the frame slots. The maximum
number of modules the frame will accept is ten. Figure 3 illustrates the rear
connector plate for an 8900 Series frame.
DA10
J1J2
O
J3J4
U
T
J5J6
J7J8
J9 J10
IN
DA9
J2
J1J2
O
J4
J3J4
U
T
J6
J5J6
J8
J7J8
J9 J10
IN
J1J2
J3J4
J5J6
J7J8
J9 J10
Figure 3. 8900 Series Frame Rear Connector
Note Input/Output mapping of the rear connector configuration is provided in a silk-
Loopthrough Input
Connect an input source to one of the loopthrough input connectors, J9 or
J10 (See Figure 4). Terminate the unused connector into 75
DA8
O
U
T
IN
DA7
J1J2
J2
O
J3J4
J4
U
T
J5J6
J6
J7J8
J8
J9 J10
IN
DA6
J1J2
O
J3J4
U
T
J5J6
J7J8
J9 J10
IN
DA5
J1J2
J2
O
J3J4
J4
U
T
J5J6
J6
J7J8
J8
J9 J10
IN
DA4
J1J2
O
J3J4
U
T
J5J6
J7J8
J9 J10
IN
J2
J4
J6
J8
screened representation on the top side of the 8911 module.
DA3
J1J2
O
J3J4
U
T
J5J6
J7J8
J9 J10
IN
DA2
J1J2
O
J3J4
U
T
J5J6
J7J8
J9 J10
IN
.
DA1
J1J2
O
J3J4
U
T
J5J6
J7J8
J9 J10
IN
0544_01
Figure 4. Typical Module Input and Outputs
8911 Instruction Manual5
8911 AES/EBU Reclocking Distribution Amplifier
Ω
Ω
Outputs
There are eight identical outputs for the 8911 module—J1 through J8. The
destination equipment should have an input impedance of 75
has loopthrough inputs, in which case the unused loopthrough connector
must be terminated into 75
Testpoints and Indicators
The 8911 DA has ground and +5V testpoints easily accessible on the front
edge of the module (see Figure 5).
Between the testpoints is a green Power On LED.
The Lock LED on the front of the module is on when the reclocking chip has
locked on the incoming AES/EBU signal.
unless it
.
+5V
Ground
RECLOCKING DA
Power
OK LED
Lock
LED
Figure 5. 8911 Testpoints and Indicators
8911
AES/EBU
0544_02
68911 Instruction Manual
Service
Service
The 8911 modules make extensive use of surface-mount technology and
programmed parts to achieve compact size and adherence to demanding
technical specifications. Circuit modules should not be serviced in the field.
If your module is not operating correctly, proceed as follows:
■
Check frame and module power and signal present LED
■
Check input signals
■
Check cables and connections
■
Verify that source equipment is operating correctly
■
Check output connections
Refer to Figure 5 for supply voltage test points on the 8911 module.
If the module is still not operating correctly, replace it with a known good
spare and return the faulty module to a designated Grass Valley repair
depot. Call your Grass Valley representative for depot location.
Refer to the
Contacting Grass Valley Group at the front of this document for
the Grass Valley Customer Service Information number.
8911 Instruction Manual7
8911 AES/EBU Reclocking Distribution Amplifier
88911 Instruction Manual
Index
B
block diagram
2
C
connectors
input
5
output
controller
controller module
6
4
4
E
environmental
3
F
frame
4
functional description
I
2
termination
6
P
performance
power requirements
power supply
3
4
R
repair depot7
S
specifications3
T
termination5
testpoints6, 7
troubleshooting7
3
impedance
connectors
indicators
input
loopthrough
specification
6
6
53
M
module installation
4
O
outputs
8911 Instruction ManualIndex-1
5
connectors
specification
6
3
Index-28911 Instruction Manual