Grass Valley 2000A89 User Manual

2000A89
8900 MODULE ADAPTER
Instruction Manual
071-8030-00
FIRST PRINTING: AUGUST 2000
Contacting Grass Valley Group
Region Voice Fax Address Web Site
North America (800) 547-8949
530-478-4148
Pacific Operations +852-2585-6688
Support: 852-2585-6579 U.K., Europe, Asia, Middle East +44 1753 218 777 +44 1753 218 757 France +33 1 45 29 73 00 Germany +49 221 1791 234 +49 221 1791 235
Copyright © Grass Valley Group. All rights reserved.
This document may not be copied, in whole or in part, or otherwise reproduced, except as specifically permitted under U.S. copyright law, without the prior written consent of Grass Valley Group, P.O. Box 599000, Nevada City, CA 95959-7900 USA. GRASS VALLEY GROUP is a registered trademark and Grass Valley is a trademark of Grass Valley Group. All registered trademarks and trademarks are prop­erty of their respective holders. Grass Valley Group products are covered by U.S. and foreign patents, issued and pending. Product options and specifications subject to change without notice. The informa­tion in this manual is furnished for informational use only, is subject to change without notice, and should not be construed as a commitment by Grass Valley Group. Grass Valley Group assumes no re­sponsibility or liability for any errors or inaccuracies that may appear in this publication.
(530) 478-3347 Grass Valley Group
+852-2802-2996
P.O. Box 599000 Nevada City, CA 95959-7900 USA
www.grassvalleygroup.com

Contents

Preface
2000A89 Module Adapter Assembly
About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Compatible 8900 Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Loop-through Input. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Outputs/Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Power Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Index
2000A89 Instruction Manual iii
Contents
iv 2000A89 Instruction Manual

Preface

About This Manual

This manual describes the features of a specific module of the 2000 Series Modular Products family. As part of this module family, it is subject to Safety and Regulatory Compliance described in the 2000 Series frame and power supply documentation (see the 2000 Series Frames Instruction
Manual ).
2000A89 Instruction Manual v
Preface
vi 2000A89 Instruction Manual

2000A89 Module Adapter Assembly

Introduction

The 2000A89 Module Adapter Assembly consists of a 2000 Series rear media module and front slot adapter that allows compatible 8900 modules to be installed in the front slot of a 2000 Series frame (see Compatible 8900
Modules on page 5 ). The 2000A89 module adapts the 8900 mechanical and
electrical connections to the 2000 Series frame. The module has an on-board ±12V power supply to meet 8900 voltage requirements. The 2000A89 assembly includes:
A rear mount module with:
Two BNCs providing a floating-shield 75 connection,
Eight 75
±12V power supply that is fused on the input side and short-circuit protected on the output side.
A front frame slot guide assembly to compensate for the width of the narrower 8900 module.
BNC input/output connectors, and
loop-through input
2000A89 Instruction Manual 1
2000A89 Module Adapter Assembly

Installation

Installation of the 2000A89 module adapter consists of:
Installing the adapter board in the corresponding rear media slot,
Installing the front slot guide assembly in the desired frame slot, and
Installing the 8900 module.
The 8900 modules can be plugged in and removed from the 2000A89 with
power on. Refer to the specific 8900 module manual for power-up, cabling,
and configuration information.
Perform the following to install the 2000A89 Adapter:
1.
Install the 2000A89 Adapter module in the selected rear slot. The module slides into guides on each side of the frame slot and
secures on the alignment post on the mid-frame motherboard (refer to
Figure 1). Screw locks secure the module in the slot. A Power OK LED
should be visible from the front of the frame when power is applied (see Power Up on page 7 ).
Figure 1. 2000A89 Adapter Module Installation
2000 frame (rear view)
Rear alignment
post and receptacle
2000A89 module
Board edge guides (both sides)
Screw lock (both sides)
8030-05
2 2000A89 Instruction Manual
2.
Figure 2. 2000Series Frame
Installation
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(12)
Front Media Modules Slots 1-12
Install the Slot Adapter in the selected front media slot. There are twelve media slot locations in the front of the 2000T3 frame
to accommodate either analog or digital modules (Figure 2). The 8900 front slot adapter installed as shown in Figure 3 allows the narrower 8900 module to be installed.
The slot adapter slides along the card guide on the right side of the frame and onto the alignment post on the mid-frame motherboard. The front of the assembly is then secured in the track by the locking screw.
8030-04
Figure 3. 2000Series Front Slot Adapter
2000 Frame (front view)
Alignment post
and receptacle
Support track for 8900 modules
Locking nut
Slot Adapter
8030-03
Locking screw
2000A89 Instruction Manual 3
2000A89 Module Adapter Assembly
Install the 8900 module in the proper front media slot. The right edge of the 8900 module slides into the board edge support
track while the left side is inserted between the board edge guides. The 50-pin rear connector should easily align with the rear connector on the adapter module. Gently press the module ejector tab to seat the module.
Figure 4. 8900 Module Installation
3.
2000 Frame (front view)
Mating connectors
Board
edge
guides
Ejector tab
8900 Module
Board edge support track
1
2
3
4
65
7
8
8
76
5
4
3
21
8030-07
4 2000A89 Instruction Manual

Compatible 8900 Modules

The following 8900 modules are compatible with the 2000A89 Adapter module:
8911 AES/EBU Reclocking DA
8914 Dual AES/EBU DA
8916 AES/EBU Auto-tracking Delay DA
8920MUX Video/Audio Multiplexer 8920DMX Video/Audio Demultiplexer
8931 Fanout DA
8936 Auto Reclocking DA
8941 Component Digital Monitoring DA 8950ADC Component A-to-D Converter
Installation
*
8960DEC NTSC/PAL to SDI Decoder and 8960ENC SDI to NTSC/PAL Encoder without optional 8900FSS
8980TLS Tri-level Sync HDTV Generator 8990ARC SDI Aspect Ratio Converter
Some Grass Valley 8800 and 8500 video DAs with large front panels can also be installed in the 2000A89 Adapter but require two media module slots for vertical clearance.
The maximum number of 8900 modules allowed in a frame is determined by frame cooling capacity. Refer to the 2000 Frames Instruction Manual and the specific 8900 module manual for power and cooling requirements.
*
Some versions of this module cannot use the bottom media module slots and will require two module slots for component clear-
ance. Contact Grass Valley Customer Support for information..
With the 8900FSS option installed, these modules require two media slots for component clearance.
2000A89 Instruction Manual 5
2000A89 Module Adapter Assembly

Cabling

The specific function of each 2000A89 BNC connector is determined by the
8900 module that is installed.
Loop-through Input
As in the 8900 frame, connectors J9 and J10 function as a loop-through
input connections (see Figure 5). Terminate the unused connector into 75
if the signal is not looped to other equipment.
Figure 5.
2000A89
IN
J10 J9 J8 J7 J6 J5 J4 J3 J2 J1
Input/Output Connectors
10
J1
O
J3
J5
J7
U T
J9 J10
IN
J2
J4
J6
J8
J4
J6
J8
J2
Connector J numbers correspond to 8900 connector numbering J1 to J1, J2 to J2, etc.
2000
A89
8030-02
Outputs/Inputs
The 2000A89 provides eight BNCs (J1 through J8) for direct (non-looping)
signal connections. The J numbers indicate the same wired connection to
the 8900 module as occurs in the 8900 frame rear connector.
6 2000A89 Instruction Manual

Power Up

Power Up
A greenLED, visible from the front of the frame, indicates both +12 and -12 Volts are present on the adapter module.
Figure 6. LEDs and Configuration Switches
Power OK LED on Adapter module
8030-06
2000 Frame (front view)
Refer to the instruction manual for the installed 8900 module for its LED status indicators.
2000A89 Instruction Manual 7
2000A89 Module Adapter Assembly

Service

The 2000A89 modules use surface-mount technology to achieve compact
size and adherence to demanding technical specifications. Circuit modules
should not be serviced in the field.
If your module is not operating correctly, proceed as follows:
Check frame and module power LEDs.
Check for presence and quality of input signals. Verify that source equipment is operating correctly.
Check cable connections.
If the 8900 module is not receiving +12 or -12 Volts, check the Adaptor
module’s Fuse F1 (see Figure 7).
If the module is still not operating correctly, replace it with a known good
spare and return the faulty module to a designated Grass Valley repair
depot. Call your Grass Valley Group representative for depot location.
Refer to Contacting Grass Valley Group at the front of this document for the
Grass Valley Customer Support information number.
Figure 7. 2000A89 Adapter Module Fuse and Voltage Testpoints
Fuse
2A, 125V F
Voltage testpoint header
8030-01
8 2000A89 Instruction Manual
Specifications
Specifications
Table 1. 2000A89 Specifications
Parameter Value
Input
Signal type Determined by 8900 module type: component/composite analog,
Number of inputs 1 loop-through Connector type 75 Ω BNCs Signal level According to signal standard Return Loss >30 dB to 5.5 MHz
Output to input isolation >40 dB to 5.5 MHz
Electrical length 1.6 ns from BNC to board edge
Outputs/Inputs
Number of outputs/inputs 8 Connector type 75 Ω BNC Signal type Determined by 8900 module type: component/composite analog,
Signal level According to signal standard Return loss >35 dB to 5.5 MHz
Output isolation >40 dB to 5.5 MHz
Electrical length 1.3 ns from BNC to board edge
Power)
Input power maximum 20 Watts +12 V output +12.35 V ±0.2 V from 0 to 850 mA load
-12 V output -12.35 V ±0.2 V from 0 to 350 mA load
Environmental
Operating temperature range 0 to 45 degrees C Non-operating temperature -10 to +70 degrees C Operating humidity range 10 to 90% non-condensing
Mechanical
Weight 1 lb (0.45 kg)
Power Requirements
Supply voltage +24 V Power consumption Module dependent
serial digital component
>13 dB 10 to 270 MHz >13 dB 270 to 360 MHz
>20 dB 10 to 270 MHz >20 dB 270 to 360 MHz
serial digital component
>13 dB 10 to 270 MHz >13 dB 270 to 360 MHz
>20 dB 10 to 270 MHz >20 dB 270 to 360 MHz
2000A89 Instruction Manual 9
2000A89 Module Adapter Assembly
10 2000A89 Instruction Manual

Index

C
connectors
input/output
consumption, power
6
9
E
environmental specifications
F
9
frame
I
input specification
9
L
loop-through
6
9
specifications 9
T
termination 6 troubleshooting 8
V
voltage 9
M
media slots
3
O
output specification
P
performance power requirements
9
R
repair
8
S
slot adapter
3
9
9
2000A89 Instruction Manual Index-1
Index-2 2000A89 Instruction Manual
Loading...