2 How To Mount The Sensor 4 Recording
Check the operating direction of the sensor unit, then
GS-3AT
GS-3AT-UM-151
For GL100
securely mount it using four M3 screws to what is to be
measured.
3-axis Acceleration / Temperature Sensor
1. Connecting to the module
When connecting this module, you can also use the GS extension cable
(GS-EXC; sold separately) for more convenient connection.
USER’S MANUAL
Thank you very much for buying this GRAPHTEC product.
This product is a measurement sensor (hereafter “module”) that
connects to the GL100-N/GL100-WL.
These directions describe preparations and cautions before
measurement.
To ensure safety, please read the operation instructions, etc.
For details on the warnings and how to handle this module, please
read the Quick Start Guide or USER'S MANUAL included on the
CD-ROM (included in the GL100 packaging)
Confirmation of the exterior
After opening the package, please confirm that there are no
problems (scratches and dirt) on the exterior before use.
Confirmation of the attached items.
User’s manual (this book): 1
•
If by any chance faults are found, please contact the store where you
bought the item.
* Please note that items mentioned in this book may change without
prior notice.
MANUAL-A604309061
1 Part Names
This section describes the name and function of each part.
1. Sensor unit
4. Connector
4. Cable packing
GL100 main module
1. Sensor unit ...................
The 3-axis acceleration and temperature
sensor are built in this module.
2.
Sensor mounting holes
3. Connector .....................
Used to fix the sensor.
..
Used to connect to the connector on the
GL100 module.
4. Cable packing ...............
This packing is used when connecting the connector.
This sensor unit is dustproof and splash-resistant to IP54
standards. It can be used in the same conditions as the
module.
Please take care not to drop or shock the sensor.
After connecting the GL100 to modules or sensors, please always check/set the
time and date.
2. Sensor mounting holes
Object to be measured
Sensor unit mounting dimensions
(Unit: approx. mm)
< Extension cable >
The module can be used approx. 1.5 m away from the GL100 by using an
extension cable for GS (GS-EXC). However, you cannot connect and use multiple
extension cables.
3 How To Measure
1. Power supply
(Refer to Quick Start Guide or USER’S MANUAL.)
Connect this module while power is being supplied to the GL100 by a battery
or USB cable.
2. Start-up and operation
(1) Screen display menu flow
After power-on, the GL100 is ready for operation by holding down [MENU] key.
When the module is connected, “Module Type Recognition” screen is displayed.
When the module is not connected, “Module Unconnected State” screen is
displayed.
Operate in accordance with the displayed instructions.
S ENSO R E RRO R!!
P leas e c onn ect
the sen sor
QU IT k ey to Pow er O ff
BA T LA N
”P le ase w ait ”
GL 100- 3AT
S leep ing !!
E NTER ke y t o s tart
QU IT k ey to Pow er O ff
BA T LA N
G L1 00- 3A T
I ni tia li zin g!!
(2) Free-running screen
ST OP A LM. 1 :2 8
MO DE :D IR .+ 27 .4 3℃
Xp ea k: + 0. 02 G
Yp ea k: + 0. 02 G
Zp ea k: + 0. 02 G
BA T L AN SD S : 0 .5 s
3. Setting
(1) Setting screen operation
Item selecting screen
Press the [MENU] key on the free-running screen to go to the setting screen.
<How to set>
Select the item with the directional keys ( ) and press the [ENTER] key.
[A MP] 1 /1 0
XY Z:5 ▽
If the submenu shows then there are selections in those directions.
Fixing screw
If the sensor’s mounting is loose, it will give inaccurate
readings.
51 19.5
44 4.5
36
44
Module unconnected state
<Operation>
Connect the module.
Recognition of module types
Standby state
<Operation>
Press [ENTER] key.
Module start-up
Hold down the [QUIT] key (approx. three seconds)
to put the module into standby state.
When running on batteries, the module will
automatically go into standby state after three
minutes of no operation.
Press the [ENTER] key while in standby state to
return to the free-running screen.
Ra nge (G )
2
5
1 0
[D ATA ] 2 /1 0
ME AS. Mo de: Di rec t▽
Sa mpl in g : 1s ▽
SA MP. Mo de: Pe ak▽
Ca ptu re MO DE :CO NT. ▽
Ca ptu re DE ST :SD Ca rd ▽
Fr ee CA PA: 49 818 0
Numerical entry screen
<How to set>
Numbers can be inputted by increasing or decreasing the value with the
and keys.
[D ate /T ime ] 7 /1 0
Ty pe: Y Y:M M: DD▽
Da te: 2 014 -0 1-0 4
Ti me: 03: 18 :26 ▽
(2) AMP setting
Select the acceleration range (shared XYZ ranges)
[A MP] 1 /1 0
Ra nge (G )
XY Z:5 ▽
AMP input condition settings (XYZ)
Range 2, 5, 10 (G)
<Unit settings>
From the OTHER-2 screen, you can switch between
acceleration displays in G or in m/s2, and between
temperature displays in Celsius (°C) or Fahrenheit (°F).
or 20, 50, 100 (m/s2)
(3) DATA setting
You can select data processing.
Direct : The value obtained by peak, average and RMS processes with
respect to each set sampling is displayed.
(Sub-sampling interval is fixed at 5 ms.)
Peak: Displays the data’s largest value
51
Average: Displays the mean value
RMS: Displays the root mean square value
Memory : At the selected sampling intervals, the set memory size contents
will be recorded to the recording medium.
If it is set to pre-trigger, data will be recorded starting at the set
memory size percentage.
<Example of pre-trigger 25%>
Memory size (Memory size set)
(1) Recording
Press the [START/STOP] key to start measuring with the set conditions.
After pressing [START] key, when the module is in awaiting recording start,
“ARMED” is displayed, and then when recording is started, "REC" is displayed.
RE C. ALM . 1 :2 8
MO DE :D IR .+ 27 .4 3℃
Xp ea k: + 0. 02 G
Yp ea k: + 0. 02 G
Zp ea k: + 0. 02 G
When battery
replacement
is required, “BAT”
is displayed.
BA T L AN SD S : 0 .5 s
LAN: displayed when the wireless LAN connection is enabled.
The module’s status is shown with the lamp display.
STATUS (Orange)
Accessing SD card
Low battery
Alarm active
POWER(Green)
Power supplying
Wireless LAN connection
possible status
When accessing an SD card, do not remove the SD card. The
•
data may not write properly or the SD card may be damaged.
When “low battery” is displayed, replace the battery or
•
connect the USB interface to supply power as soon as
possible. Caution: Batteries cannot be replaced when
recording data. Replace them after the recording has finished.
When alarm occurs, “ALM” is displayed.
Current time
Note: The current time display can
be switched to the elapsed
time with the [QUIT] key when
recording.
“SD” is displayed during accessing the SD card.
Sampling interval
Access light
Flash once every 5 seconds
Flash once every 10 seconds
Flash once every 10 seconds
Flash once every 5 seconds
(2) Recording completion
Recording begins 25% before the trigger point
Trigger point
[D ATA ] 3 /1 0
ME AS. Mo de: Di rec t▽
Sa mpl in g:1 s▽
SA MP. Mo de: Pe ak▽
Ca ptu re MO DE :CO NT. ▽
Ca ptu re DI ST :SD Ca rd ▽
Fr ee CA PA: 49 818 0
DATA recording condition settings
MEAS. Mode
Direct
Sampling
SAMP.
Mode
Memory
Sampling
Memory size
Pre-trigger
Capture MODE
Capture DIST
Direct, Memory
500 ms, 1, 2, 5, 10, 20, 30 s,
1, 2, 5, 10, 20, 30, 60 min
Peak, Average, RMS
5, 10, 20, 50, 100 ms
16, 32, 64, 128 k
Off, 10, 25, 50, 100%
CONT, 1 Hour, 24 Hour
Memory, SD Card
(4) TRIGGER setting
Select the conditions for beginning data recording after measurement starts.
Off :
Pressing the [START/STOP] key on this module will start/stop recording.
• Press the [START/STOP] key to stop measuring.
• The screen display will change to the standby
screen display.
• Press [ENTER] key to change to the
free-running screen display.
5 How To Confirm The Data
Check the recorded data with the application software included with
this module using the method below (for details, refer to the USER'S
MANUAL).
(1) Connect the USB interface and check the online data
(2) Insert the SD card into PC and check the data directly
(3) Check the data directly from PC via wireless LAN
GL 100 -3 AT
S lee pi ng! !
E NTE R key t o s tar t
QU IT ke y t o Pow er Of f
BA T L AN
Start : The recording will start with the trigger source conditions after
pressing the [START/STOP] key.
The recording will stop after pressing the [START/STOP] key.
6 Specifications
Stop : The recording will start after pressing the [START/STOP] key
↑
1 s
2 s
5 s
1 0s
2 0s
↓
and will be stopped with the trigger source conditions.
[T RIG GE R] 3 /1 0
TR IG Se tti ng :Of f▽
TR IG So urc e: Of f▽
TRIGGER capture condition settings
TRIG setting
TRIG Source
Off, Start, Stop
Off
Level Off
/ Mode Level G
H Value setting
L
Alarm
Date Date, Time
*
The level depends on the setting range.
(5) ALARM setting
Set the alarm information. The parameters will vary depending on the
setting range. Please set the number level.
[A LAR M] 4 /1 0
Al arm :O ff▽
ALARM settings
Alarm Off
Level Off
/ Mode Level G
H Value setting
L
* The level depends on the setting range.
(6) ADJUST setting
This function is used to adjust static acceleration value of the sensor unit
installing state to zero level.
If the module is operated in an unstable state, the static acceleration value is not
stable.
Also, do not give external vibration, etc. during ADJUST setting.
[A DJU ST ] 5 /1 0
Of fse t Adj us t: Set ▽
Se tti ng ▽
CH :
X: +0. 00 8G
Y: -0. 09 3G
Z: +1. 05 9G
ADJUST setting information
Offset Adjust
Setting
* When ADJUST function is not used, set to Reset.
Set, Reset
Yes ENTER
No QUIT
Item
Measurement data
Acceleration range
Measured acceleration
accuracy(Non-linearity)
Band
Noise
Measurement
temperature range
Measured temperature
accuracy
Response time
(temperature)
Measurement mode
Memory capacity
(Memory mode)
Pre-trigger
(Memory mode)
Sampling interval
Alarm
ADJUST function
Waterproof sensor
Cable length
Usage environment
External dimensions
[W×D×H] (approximate)
Weight (approximate)
XYZ Charge / Temperature
Contents
±2 G (20m/s2), ±5 G (50m/s2), ±10 G (100m/s2)
±2% of F.S.
0 to 100Hz
25 mGrms
-10 to 50℃ (14°F to 122°F)
-10 ≤ TS ≤ 50 ±1.0 (℃)
Approx. 300 sec.
Memory mode and Direct mode
16, 32, 64, 128 k sample
OFF / 10, 25, 50, 100%
<Memory mode>
5,10, 20, 50, 100 ms
<Direct mode>
0.5, 1, 2, 5, 10, 20, 30 sec.
1, 2, 5, 10, 20, 30, 60 min.
OFF / Level
Set / Reset
Note: This function will set the current static acceleration value to
zero.
IP54
approximate 20 cm
-10 to 50°C, 80% RH or less (non-condensing)
51 × 36 × 19.5 mm (not including protruding parts)
64g
503-10 Shinano-cho, Totsuka-ku Yokohama
244-8503, Japan
August 1, 2014