Grant Vortex Mag One
Universal Magnetic Central Heating Filter
Installation and Servicing Instructions
UK | DOC 0098 | Rev 2.0 | October 2017

IMPORTANT NOTE FOR INSTALLERS
These instructions are intended to guide Installers on the
installation, commissioning and servicing of the Grant Vortex Mag
One magnetic lter. After installing the magnetic lter, leave these
instructions with the user.
SPECIAL TEXT FORMATS
The following special text formats are used in these instructions
for the purposes listed below:
! WARNING !
Warning of possible human injury as a consequence of not
following the instructions in the warning.
! CAUTION !
Caution concerning likely damage to equipment or tools
as a consequence of not following the instructions in the
caution.
! NOTE !
Used for emphasis or information not directly concerned
with the surrounding text but of importance to the reader.
PRODUCT CODES COVERED
These instructions cover the following product codes:
VM01/X
SERVICING
The magnetic lter should be serviced at least every twelve
months and the details entered in the Service Log in these
instructions.
GRANT ENGINEERING (UK) LIMITED
Hopton House, Hopton Industrial Estate, Devizes, Wiltshire, SN10 2EU
Tel: +44 (0)1380 736920 Fax: +44 (0)1380 736991
Email: info@grantuk.com www.grantuk.com
This manual is accurate at the date of printing but will be superseded and should be disregarded if specifications and/or appearances are changed in the interests of continued product improvement.
However, no responsibility of any kind for any injury, death, loss, damage or delay however caused resulting from the use of this manual can be accepted by Grant Engineering (UK) Limited, the
author or others involved in its publication.
All good sold are subject to our official Conditions of Sale, a copy of which may be obtained on application.
© Grant Engineering (UK) Limited. No part of this manual may be reproduced by any means without prior written consent.
Page 2

CONTENTS
1 INTRODUCTION 4
1.1 General 4
1.2 How a magnetic lter works 4
1.3 Safekeeping of the installation 4
instructions
1.4 Product contents 4
1.5 Installation 5
1.6 Location 5
1.7 Orientation 5
1.8 Access and clearances 5
1.9 Reducing valves 5
1.10 Magnetic cautionary advice 5
2 TECHNICAL DATA 6
2.1 Materials specication 6
2.2 Magnet specication 6
2.3 Flow rate and pressure drop 6
2.4 Dimensions 7
3 INSTALLATION 8
3.1 Installation procedure 8
3.2 Number of magnetic lters required 8
3.3 Installing with pipe sizes of 22 mm 8
or 28 mm
3.4 Installing with pipes sizes of 35 mm 8
3.5 Cascade systems 8
4 COMMISSIONING 9
5 SERVICING 9
6 CHEMICAL DOSING 9
7 GUARANTEE 10
8 SERVICE LOG 11
Contents Page 3

1 INTRODUCTION
1.1 GENERAL
The Mag One magnetic central heating lter is the ideal solution
to costly and unnecessary system breakdowns caused by both
magnetic and non-ferrous particulate in uid based systems.
Thanks to its innovative triple action magnetic ltration system,
it identies and retains all types of magnetite and non-ferrous
debris.
The Mag One magnetic central heating lter can be used on
all types of central heating systems in any orientation and it is
recommended, for maximum effect, that it be installed on the
return leg of the circuit, between the last radiator and the boiler/
heat pump.
The isolating at face ball valves, provided with the magnetic lter,
make maintenance and installation quick and simple.
As well as being tted in conjunction with the installation of a new
system, the Mag One magnetic lter is well suited to being retrotted to an existing system where the boiler/heat pump is being
replaced – protecting new components and increasing the life
span and effectiveness of existing ones.
1.2 HOW A MAGNETIC FILTER
WORKS
Through a combination of innovative product design and a
clever use of the laws of physics, water is guided through the
components of the Mag One to achieve maximum ltration with
each pass of the circuit.
Water enters the lter through our ingenious diverter block and
then passes into the magnetic lter 500 ml capacity pressure drop
chamber.
Here, particulate is forced through the non-ferrous lter and down
towards the magnet. Through a process of natural convection,
water then circulates back to the top of the lter and back into the
system leaving all magnetite and particulate debris captive at the
base of the lter’s magnetic core.
All system contaminants are then easily removed during servicing
by isolating the Mag One from the system and removing the
magnet from the screw cap at the top of the pot then opening the
drain valve, removing the majority of contaminants within the pot
in seconds.
1.3 SAFEKEEPING OF THE
INSTALLATION INSTRUCTIONS
These Installation and Servicing Instructions must be handed over
to the householder on completion of the installation. They should
be kept for future reference as necessary.
1.4 PRODUCT CONTENTS
The following are included with the Mag One:
• 1 x Installation and Servicing Instructions
• 1 x Magnetic Filter body
• 1 x Accessories box containing:
• 1 x Connection block
• 2 x Isolating Valves
• 1 x Resealable bag containing:
• 1 x Large o-ring for screw seal
(1 x spare)
• 2 x Large at washers for the inlet connection
(1 x spare and 1 to be tted during installation)
• 4 x Small at washers for between the connection block
and isolating valves
• (2 x spare and 2 to be tted during installation)
• 1 x Small o-ring for manual air vent
(1 x spare)
• 1 x Resealable bag (contained within above bag) containing:
• 1 x Brass hose adaptor
• 1 x Air bleed key
• 1 x Service label
• 1 x Sealed bag containing:
• 2 x 28/22 mm reducing valves (refer to Section 1.8)
• 1 x Spanner
Figure 1-1: Mag One spanner
Section 1: IntroductionPage 4