Gram C3 Series, C3-300, C3-500, C3-1T Operation Manual

SERIES / SERIE / SÉRIE
C3
300 / 500 / 1T
OPERATION MANUAL
MANUAL DE UTILIZACION
MANUEL D´UTILISATION
INDEX English
Turn ON 7
Turn OFF
Tare / Zero
Display brightness
Hold function
Weighing accumulation function
ON / OFF Save power
Calibration using the remote controller 9
Calibration using keys of crane scale
Parameters setting using the remote controller 10
Parameters setting using keys of crane scale
7
7
7
8
8
8
9
11
2
ÍNDICE Español
Encender el gancho 15
Apagar el gancho
Tara y puesta a cero
Brillo del display
Función Hold
Función de acumulación de pesadas
Ahorro de energía
Calibración utilizando las teclas del mando a distancia 17
Calibración utilizando las teclas del gancho
Configuración de parámetros utilizando las teclas del mando a distancia 18
Configuración de parámetros utilizando las teclas del gancho
15
15
15
16
16
16
17
19
3
SOMMAIRE Français
Allumer le crochet 24
Eteindre le crochet peseur
Tare et retour au zéro
Luminosité de l’ecran
Fonction Hold
Fonction d’accumulation de pesées
ON / OFF Save power
25
Calibration avec la commande a distance 26
Calibration avec les touches du crochet
Configuration des parametres avec la commande a distance 27
Configuration des parametrs avec les touches du crochet
24 24 24
25
25
26
28
4
ENGLISH
SAFETY RECOMMENDATIONS
Before using the crane scale, please, read this manual carefully and follow the instructions.
• DON´T overload the crane scale, this could seriously damage the loadcell (repair not covered by the warranty).
• DON´T leave any weight on the hook for a long time, this reduces the accuracy of the equipment and shorts the life of the loadcell.
• Before using the scale, check rings, hooks and other parts, cotter pin, if the screw is loose and deformation loose every 3 months.
• Charge the battery when the display shows the low power indicator.
• DON’T use the crane scale in rain or storms.
• After used, hook should vertical suspended or the loadcell could be damaged.
• DON´T try to repair the crane scale. Please contact with your Distributor.
Model Capacity Division (e)
C3-300 300kg 50kg C3-500 500kg 100g C3-1T 1.000kg 200g
5
Accuracy Class III Tare range 100% Max. capacity Time of stability 10´s Overload alarm Max +9e Max. overload 125% Max. capacity Power Fwll seal rechargeable battery 6V/4AH Display Super light LED Temperature 0ºC – 40C Remote control range
20m
FUNCTION KEYS ON REMOTE CONTROL
Key Function
A – Confirm B – T/0 Tare / zero C - Accumulation D - H Hold
6
USE OF CRANE SCALE
Turn ON
Press the key on the crane, the scale begin the self test, at the same time, auto-zero initialization, then the display will show power status “Pbt85” (85% power) and finally the crane scale enters to weighing mode.
Turn OFF
Press the display will show “PA80” (80% power), 1.5 seconds later, the display will show “off” and scale power off.
key for 3 seconds or D and B together on remote control, the
Tare / Zero
To obtain the net weight of a product. Place a container and press the key or B on remote control, the display shows zero value, put the product into the container, the display will show the net weight of the product.
Display brightness
1. With the crane scale disconnected, press the key press also the key .
2. The display will show: “Dsp X”.
3. Available options:
X=0 Low brightness. X=1 High brightness.
X=2 Automatical brightness (when weight changes, the high
the same time
7
brightness is activated, after 20 seconds of stability, the low brightness is activated).
4. Press
5. Press the
key to select the desired mode.
key to return to normal weighing mode.
Hold function
1. Press the key D on remote control, the display´s reading will remain locked for 30 seconds.
2. Press again the key D on remote control, the Hold function will be turn off, the balance will return to normal weighing mode.
Weighing accumulation function
When the weight is stable, press the C key on the remote control to accumulate the display values and view the accumulation times “n32”, 2 seconds later, back to normal weighing mode.
To cancel accumulation function, press the B key on remote control and returns to normal weighing mode.
ON / OFF Save power
Press the A key on remote control for 2 seconds, the display will power off, only shows “-“ to save power.
Press the A key on remote control for 2 seconds, back to normal weighing mode.
8
CALIBRATION
Calibration using the remote controller
1. Power on the crane scale and keep pressed the D key until display shows “CAL SP”.
2. The display will show “CAL 00”, press A key once to display “CAL00”.
3. Do not hang on the hook any goods at this time.
4. Display will show “LOAD”, press the A key until view “-------“ and then later on display “LOAD”.
5. Press the D key to input the calibration weight value (long press D key to increase the number of digit, click to the left shift).
6. Lifting weights, until steady 4 to 5 seconds.
7. Press the A key to show “--------“, 2 seconds after the display of the hanging weight values, calibration is finished, put weight down, turn it off.
Calibration using keys of crane scale
1. When power on and self detecting, keep pressed shows “CAL SP”.
2. Press the
3. Do not hang on the hook any goods at this moment.
4. Press the the display will read “LOAD”.
key once the display shows “CAL00”.
key once the display shows “--------“, after few seconds,
key until display
9