Gram BAKER GA 950, BAKER GA 550 User Manual

765041938 Rev. 002 1
GRAM BAKER GA 950 / GA 550
User manual

765041938 Rev. 002 2

Gram Commercial A/S Aage Grams Vej 1 6500 Vojens +45 73 20 12 00 www.gram-commercial.com
765041938 Rev. 002 3
Contents
Application ............................................................................................................................................... 5
Safety information ................................................................................................................................... 6
Location ................................................................................................................................................... 7
Placement of multiple units next to each other ................................................................................... 9
General description ............................................................................................................................... 10
Electrical connection ............................................................................................................................. 11
Humidifier .............................................................................................................................................. 12
Water drain ............................................................................................................................................ 12
Water connection .................................................................................................................................. 13
General use ........................................................................................................................................... 14
Commissioning, functional description .............................................................................................. 15
Connection and disconnection of the main circuit breaker .............................................................. 16
User interface to the unit (touchscreen) ............................................................................................ 17
Settings for the unit: date, time and language .................................................................................. 17
Selection of language .......................................................................................................................... 18
Setting of clock (time).......................................................................................................................... 19
Setting the date .................................................................................................................................... 19
Setting of date format .......................................................................................................................... 20
Season: summer time/winter time ...................................................................................................... 20
Temperature measurement, units of Celsius or Fahrenheit. ........................................................... 20
Setting of ending times for programs for each weekday .................................................................. 21
Preconfigured programs ...................................................................................................................... 22
Selection and start of a program ........................................................................................................ 22
Selection of ending time for the program .......................................................................................... 23
Changing of established date and ending time for the program...................................................... 24
Changing of further settings before program start ............................................................................ 25
Display during program execution (fig. 32) ....................................................................................... 27
Changing a running program .............................................................................................................. 28
Interruption of the currently running program ................................................................................... 29
Storage of user-defined (own) programs ........................................................................................... 29
Manual programs ................................................................................................................................. 33
Deletion of a specially created program ............................................................................................ 33
Alarms/error messages ....................................................................................................................... 34
Temperature alarms ............................................................................................................................ 34
Sensor alarms ...................................................................................................................................... 35
Vapour system alarms ......................................................................................................................... 35
Other alarms ........................................................................................................................................ 35
Door closing mechanism ....................................................................................................................... 36
765041938 Rev. 002 4
Power failure ......................................................................................................................................... 36
Cleaning ................................................................................................................................................ 36
Door gaskets ......................................................................................................................................... 37
Long term storage ................................................................................................................................. 37
Service .................................................................................................................................................. 38
Disposal ................................................................................................................................................. 39
EC-Declaration of conformity ................................................................................................................ 40
Wiring diagram ...................................................................................................................................... 41
Piping diagram ...................................................................................................................................... 42
765041938 Rev. 002 5
ENGLISH
Thank you for choosing a quality product from Gram Commercial.
This manual will advise you how to install, use and maintain your new product.
Before our products leave the factory, they undergo a full function and quality test. Should you nevertheless experience problems with the product, then contact your local dealer.
Gram Commercial subsidiaries and dealers placed all over the world are ready to help you.
Gram Commercial supplies warranty on all products. This warranty is subject to correct use according to specifications, where e.g. common maintenance and eventual repairs are carried out by Gram Commercial techicians or technicians approved by Gram Commercial.
Changes in installation and other use of the procuct than prescribed in this manual, might affect the operation and durability of the product.
The manual is written according to our current technical knowledge. We constantly work on updating this information, and we reserve the right to make technical changes.
Application
This product is designed for storage of foodstuff at a constant temperature. The product may not be used for chilling or freezing of foodstuff.
The product is only to be used for the purpose for which it has been expressly designed (storage of cooled or frozen items). Any other use could cause that the products stored in the product are not kept at the right temperature.
The manufacturer will not be held liable or responsible for any damage caused by improper, incorrect or unreasonable use.

765041938 Rev. 002 6
Safety information
Important
Description of symbols used in this manual.
Warning
Lacking observation to these instrucions might result in accidents with personal injury.
Important
If these instructions are not observed, the product might be damaged or destroyed.
Be aware that Gram Commercial has taken precautions to ensure that the safety of the product is in order.
Please read carefully the following information regarding safety.
It is important, that everyone who are to use or install the product, to have access to this manual.
This appliance is not intended for use by persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervison or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
The appliance might contain parts with sharp edges in the compressor compartment, and in the inside compartment.
The appliance is not to be transported on a sack truck, there is a danger of loosing the balance, causing danger to persons.
Do not pull the power cord to dicconnect the appliance, or when moving the appliance.

765041938 Rev. 002 7
Location
When receiving the product, check the packaging material for damage.
If any damage occurs at the packaging material, it should be considered if the product might have been damaged too. If the damage is substantial, please contact your dealer.
The transport pallet can be removed by loosening the screws that fasten the pallet to the product.
This task requires at least 2 persons.The heaviest part of the product is at the top. Be aware of this, when removing the transport pallet.
If the cabinet has been transported in horizontal position it must stand upright at least 2 hours before it is started to allow the oil from the compressor to run back.
765041938 Rev. 002 8
Because of the heavy weight of the product, the floor might be damaged or scratched when moving the product. Correct set up gives the most effective operation. The product should be located in a dry and adequately ventilated room. To ensure efficient operation, it may not be placed in direct sunlight or against heat-emitting surfaces. The product is designed to operate in an ambient temperature between +16C and +40°C. Avoid placement of the product in a chlorine/acid-containing environment (swimming bath etc.) due to risk of corrosion. The product and parts of the interior is equipped with a protecting film, which should be removed before use. Clean the product with a mild soap solution before use.
The set up place must be level and horizontal.
For versions with legs, use the adjustable legs to make sure that the product stands level and upright.
For versions with castors, the locking devices of the two front castors must be activated, when the product is in place. The base must be level, and the product may not be placed on frames or the like.
Fig. 2

765041938 Rev. 002 9
Placement of multiple units next to each other
Depending upon the temperature and humidity at the installation location as well as the correct values being set, water contained in the surrounding air may condense on the surface of a refrigerator (condensation formation) due to the design.
If multiple refrigerators or freezers are placed next to each other, then this condensation effect is stronger, plus a smaller amount of air would then circulate between the units. Hence, the minimum distance between the units must be 40 mm.
This space must not be closed off at its top or bottom, however due to aesthetical considerations it may be covered in the front by, for example, a stainless steel panel. In order to be able to clean this space, the panel must be detachable.
If it is not possible to establish free air circulation at the bottom via, for example, installation on a pedestal, then the space must not be fully sealed at the front.
Min. 40 mm
765041938 Rev. 002 10
General description
Condenser with air filter
Compressor
Display
Front panel
Vapor system
Door
Gasket
Air inlet
Air distribution plate
Foot pedal opener
Wall rail
Supports
765041938 Rev. 002 11
Electrical connection
Read the text below thoroughly before electrical connection.
The product is intended for connection to alternating current. The connection voltage (V) and frequency (Hz) are shown on the name plate in the cabinet. Only the supplied cord is to be used.
Never use an extension cord for this appliance! If a wall socket is placed in a longer distance than the length of the supplied power cord, contact an electrician to establish a wall socket within the range of the supplied power cord.
If the product is defective, it must be examined by a service electrician advised by Gram Commercial during the guarantee period, if it is a product with built-in compressor. If it is a product connected to an external compressor unit, it must be examined by the company who has connected the product to the unit. Outside the guarantee period, it is advisable to use the service advised by Gram Commercial, if possible. If this is not the case, assistance is required from a refrigeration company with knowledge of Gram’s products.
765041938 Rev. 002 12
Always disconnect the power if interruptions in power supply occur, and when electrical parts are removed/put on, and before cleaning and maintenance of the product.
Repairing of electrical/technical parts may only be performed by a service electrician from Gram Commercial or an authorised refrigeration company with knowledge of Gram’s products.
Do not use the product before all coverings are installed, so that live or rotating machine parts can not be touched.
The product is not to be used outdoor.
All earthing requirements stipulated by the local electricity authorities must be observed. The plug and wall socket should then give correct earthing. If necessary, contact an electrician.
Make sure the product is switched off at the socket before service is performed on electrical parts. It is not sufficient to switch off the product by the START/STOP key as there will still be voltage to some electrical parts of the product.
Humidifier
The cabinet is equipped with a humidifier that provides steam during proving. The humidifier consists of a water tank heated by electrodes. From the tank, steam is led into the cabinet through a pipe. The tank is automatically filled from the water supply. The tank can be flushed by switching the cabinet off at the main switch and then switching it on again. In addition, the system is automatically flushed regularly depending on water quality.
For further information on servicing and maintaining the humidifier, please consult the "Service and operation manual". For maintenance of the humidifier, request service assistance.
Water drain
Defrost water and water flushed from the humidifier are led away through a pipe on the rear of the cabinet. A water seal must be installed between cabinet and drain.
765041938 Rev. 002 13
Water connection
To provide proper steam production, the humidifier must be connected to a water supply. To assure ideal steam production, it is important that the electrical conductivity of the inlet water is measured by the installer, to assure it is within standard range. See Below Box!
Please note the following:
The electrical conductivity of the water must be in the range: 200-800 µS/cm.*
The temperature of the inlet water must not exceed 40°C.
The water pressure must be in the range 1-10 bar.
A shut-off valve, a check valve, and a filter if necessary, must be fitted to the supply pipe.
*If the electrical conductivity of the water is outside the above mentioned standard range (200 – 800 µS/cm) some controller settings, might need adjustment in order to maintain proper steam production. These adjustments must be done by a service technician, and are described in the service manual.
Indications that water conductivity is outside of standard range are:
Too poor steam production Frequently having boiler overfilled alarm
Loading...
+ 30 hidden pages