Graham Field LF1030, LF1040 User Manual

LF1030 HYDRAULIC PATIENT LIFT
LF1040 ELECTRIC PATIENT LIFT
LF1030-INS-LAB-RevB10
© 2010 GF Health Products, Inc.
Read this manual before operating your Patient Lift.
Save this manual for future use.
The most current version of this manual can be found online at
www.grahameld.com
CONTENTS
1 INTRODUCTION .............................................................................................................................. 3
2 SAFETY PRECAUTIONS ................................................................................................................ 4
WARNINGS ................................................................................................................................ 4
3 FEATURES ...................................................................................................................................... 6
4 HANDLING PROCEDURES ............................................................................................................ 7
SHIPPING AND TRANSPORTATION INSTRUCTIONS ............................................................ 7
5 ASSEMBLY INSTRUCTIONS .......................................................................................................... 8
COMPONENTS .......................................................................................................................... 8
ASSEMBLY ................................................................................................................................ 9
6 OPERATING INSTRUCTIONS ...................................................................................................... 13
LIFTING THE PATIENT ............................................................................................................ 13
7 CARE AND MAINTENANCE ......................................................................................................... 16
BEFORE EACH USE ............................................................................................................... 16
BATTERY ................................................................................................................................. 16
LUBRICATION
CLEANING ............................................................................................................................... 17
CHECKING FOR DAMAGE AND WEAR ................................................................................ 17
CARE OF SLINGS ................................................................................................................... 17
LF1030 ONLY: INSTALLATION OF 1010S005 HYDRAULIC PUMP ...................................... 17
MAINTENANCE SCHEDULE .................................................................................................. 19
......................................................................................................................... 16
8 TROUBLESHOOTING ................................................................................................................... 20
9 SPECIFICATIONS * ....................................................................................................................... 20
10 LIMITED WARRANTY ................................................................................................................... 21
11 INDEX ............................................................................................................................................ 23
GF Health Products, Inc. is not responsible for typographical errors. Packaging, warranties, products and specications are subject to change without notice.
Graham-Field and Lumex are registered trademarks of GF Health Products, Inc.
LF1030-INS-LAB-RevB10
2

1 INTRODUCTION

Congratulations on your purchase of a Lumex patient lift. The following pages will provide you with important safety and operating instructions on the use of patient lifts, slings, and accessories, as well as maintenance and warranty information. Read this manual carefully before operating your patient lift and refer to it as often as needed. Consult your Lumex dealer and/or healthcare professional with any questions or concerns regarding safe and effective techniques for operating your patient lift.
The Lumex Patient Lift is intended to aid in the transfer of an individual who is unable to indepen­dently transfer between bed, chair, wheelchair, and/or commode.
DO NOT attempt any transfer without prior approval of the patient’s healthcare provider. With their assistance, select the sling that best serves the needs, abilities, comfort and safety of the per­son being lifted. It is important that you use correct slings adapted to the body shape and weight and ability of the patient and the specic type of transfer needed.
Upon receipt of the patient lift, and prior to each use, inspect it closely to ensure that nothing is damaged, there are no loose or broken parts, that all patient lift parts are in the proper place, etc. Immediately replace any worn or broken components. Your patient lift should receive maintenance on a regular schedule and should be inspected daily for proper operation. Contact your Lumex dealer for service and repairs.
Before lifting anyone, thoroughly read the instructions in this manual. The operator should prac­tice the entire lifting procedure several times with proper supervision and with a capable individ­ual acting as patient. It is extremely important to know how a patient will feel in the patient lift. We suggest that the operator try all the various lifting slings and equipment until the operator is con­dent with how the patient lift operates. The lifting procedures should be explained to the patient before the actual lifting. Remember that safety requires the constant attention of the lift occupant and the operator. Use extreme care and common sense when operating a patient lift.
This guide covers the use of the LF1030 Hydraulic Patient Lift and the LF1040 Electric Patient Lift. Keep in mind that the basic safety procedures included in this manual are to be used as a guide only. You may nd it necessary to develop your own unique methods for safely utilizing the patient lift. Again, consult your healthcare professionals for their recommendations and never hesitate to ask for their assistance.
Note: Before attempting to assemble the patient lift, refer to the section titled “ASSEMBLY IN­STRUCTIONS” contained elsewhere in this manual. Contact your Lumex dealer if additional assistance is needed.
Note: In this manual, the person being lifted is referred to as the “patient” or “occupant” and the person operating the patient lift is called the “operator” or “attendant”.
Please note the following special statements, used throughout this manual, and their signicance:
WARNING: Indicates a potential hazard situation or unsafe practice that, if not avoided,
could result in death or serious personal injury.
CAUTION: Indicates a potential hazard situation or unsafe practice that, if not avoided,
could result in minor personal injury or product/property damage.
Note: Provides application recommendations or other useful information to ensure that you get the most from your product.
LF1030-INS-LAB-RevB10
3

2 SAFETY PRECAUTIONS

IMPORTANT: Before using patient lift, please read and adhere to the following safety precautions and warnings. Failure to do so could result in serious injury or damage to your patient lift.
Always consult your healthcare professional to determine safe methods most suitable for your individual abilities. Protect yourself, your attendant and patient lift by having it serviced regularly. If you experience any malfunction, contact your Lumex dealer immediately, as a hazardous condi­tion could result, causing personal injury or damage to your patient lift.
Periodic inspection, adjustment and replacement of worn parts are necessary to provide years of excellent service. Refer to CARE AND MAINTENANCE section of this manual.

WARNINGS

WARNING: Important! Read and understand these instructions before assembling or us-
ing the LF1030 and LF1040. If you do not understand any part of these warnings, cau­tions or instructions, contact a healthcare professional for direction in the use of this product. If the Lumex Patient Lift is not properly assembled, personal injury and damage to the Lumex Patient Lift could result.
WARNING: If components are damaged or missing, contact your dealer immediately. DO
NOT use substitute parts. Use only Lumex replacement parts. The use of non-Lumex re­placement parts could cause personal injury, property damage, and void the warranty.
WARNING: The LF1030 Hydraulic Patient Lift / LF1040 Electric Patient Lift maximum
weight capacity is 400 pounds. DO NOT exceed the maximum weight capacity.
WARNING: GF Health Products, Inc. assumes no responsibility for any damage or injury
caused by improper assembly or use of this product.
WARNING: Check all parts for shipping damage before using. In case of damage, DO
NOT USE the equipment. Contact the carrier or your authorized Lumex dealer for further instructions.
WARNING: Patient lift may tip over if used incorrectly. Read and adhere to the operating
instructions prior to lifting anyone.
WARNING: GF Health Products, Inc. strongly recommends that two caregivers take part
in the lifting process.
WARNING: When transferring a patient, always keep the patient centered over the base.
WARNING: This patient lift is designed for transfer only. It is not intended to be used for
transporting or moving a patient from one location to another.
WARNING: Never use the patient lift to lift or transfer anything other than a person.
WARNING: Ensure that lifting sling loops are correctly attached to the hooks to prevent
the patient from sliding or falling out of the sling, which could result in personal injury. Ensure that sling grip handles are always positioned away from the patient so that the smooth side is facing the patient.
WARNING: Do not lock or block the casters when lifting. The casters must be free to roll
so that the patient lift can stabilize as the patient is initially lifted from a chair, bed, or any stationary object.
WARNING: To ensure stability while lifting or transferring a patient, the patient lift legs
must be locked in the maximum open position.
WARNING: Replace any worn or broken parts immediately! Torn, cut, frayed, or broken
slings can fail, resulting in personal injury. Use only slings that are in good condition.
LF1030-INS-LAB-RevB10
4
 WARNING:Unauthorizedmodicationofyourpatientliftortheuseofnon-Lumexre-
placement parts may change the structure of the lift and could create a hazardous con­dition, which may result in serious injury and will void the warranty.
WARNING: LF1030 Hydraulic Patient Lift only: The hydraulic pump is sealed at the fac-
tory. If service is required, the unit must be returned to the factory for repair. DO NOT at­tempt to open the hydraulic pump or obtain local service; this will void the warranty and may result in damage to the unit. Consult your Lumex Dealer for further information.
WARNING: LF1040 Electric Patient Lift only: The electronics and actuator contain no
serviceable components. If service is required, the unit must be returned to the factory for repair. DO NOT attempt to open the electronics or actuator or obtain local service; this will void the warranty and may result in damage to the unit. Consult your Lumex Dealer for further information.
WARNING: Use extreme care, caution, and common sense when utilizing a patient lift.
Special attention must be given to patients who are disoriented and cannot cooperate while being lifted, such as comatose, agitated, spastic, or mentally confused persons. Consult their healthcare professional for assistance in lifting these types of patients.
 WARNING:Lumexspecicallydisclaimsresponsibilityforanybodilyinjuryorproperty
damage which may occur during any use which does not comply with federal, state or local laws or ordinances.
LF1030-INS-LAB-RevB10
5

3 FEATURES

LF1040 Electric
Patient Lift
Battery, battery charger, & control box (LF1040 Electric Patient Lift only)
Actuator (LF1040 Electric Patient Lift only)
Mast
Boom
6-point spreader bar (suspension)
Hydraulic pump (LF1030 Hydraulic Patient Lift only) See above left for LF1040 Electric Patient Lift components
Push handle
Base adjustment
handle
Locking
casters
LF1030 Hydraulic Patient Lift
LF1040 Electric Patient Lift
(unless otherwise specified,
callout applies to both lifts)
Adjustable base
Swivel casters
LF1030-INS-LAB-RevB10
6

4 HANDLING PROCEDURES

SHIPPING AND TRANSPORTATION INSTRUCTIONS

If the patient lift is to be reshipped by common carrier, it should be packed in the same carton/s in which it was received (the LF1030 is shipped in one carton; the LF1040 motor may be packaged separately from the frame).
Unpacking
1. Check for any obvious damage to the carton or its contents. If damage is evident, notify the car-
rier or your authorized Lumex Dealer.
2. Remove all loose packing from the carton.
3. Carefully remove all the components from the carton.
Note: Unless the patient lift is to be used immediately, retain boxes, containers and packing material for use in storing until use of patient lift is required.
Inspection
1. Examine the exterior of the patient lift for nicks, dents, scratches or other damage.
2. Inspect all components.
Storage
1. Store the repackaged patient lift in a dry area.
2. DO NOT place other objects on top of the repackaged patient lift.
LF1030-INS-LAB-RevB10
7

5 ASSEMBLY INSTRUCTIONS

The LF1030 patient lift is packed in one carton. The LF1040 motor may be in a separate carton. Components are shown in illustration below and called out in list below illustration.

COMPONENTS

3
4
7
6
5
8
LF1030 hydraulic patient lift components
Item Qty Description
1 1 Mast/Boom/Pump assembly (LF1030)
1 Mast/Boom/Actuator assembly (LF1040)
* Note: Actuator, Charger, Pendant and mounting items are packaged separately on LF1040.
2 1 Base
3 1 Base adjustment handle
4 2 Push handle
5 1 Spreader bar to boom attachment bolt
6 1 Spreader bar to boom attachment rod
7 1 Spreader bar
8 1 Assembly wrench set
1
2
LF1040 *
LF1030-INS-LAB-RevB10
8
Loading...