Graham Field JB0160-015B, JB0160-015, JB0160-010B, JB0160-010-220, JB0160-010 User Manual

...
OXYGEN CONCENTRATOR
USER MANUAL
Model Numbers JB0160-010B, JB0160-010,
JB0160-010B-220, JB0160-010-220
and
JB0160-015B, JB0160-015, JB0160-015B-220,
JB0160-015-220 with O2 Sensor
Important: Do not operate this concentrator without
rst reading and understanding this manual!
Save this manual for future use.
CONTENTS
1 SAFETY ................................................................................... 3
Important Information .................................................................. 3
Before Installation......................................................................... 3
Placement ......................................................................................4
Fire Warning & Explosion ............................................................. 4
Maintenance .................................................................................. 5
Radio Frequency Interference ..................................................... 5
Additional Safety Warnings ..........................................................6
2 FEATURES .............................................................................. 8
Summary........................................................................................ 8
Characteristics .............................................................................. 8
3 HANDLING .............................................................................. 9
GF Health Products, Inc. Freight Policy ......................................9
Unpacking .....................................................................................9
Inspection .................................................................................... 10
Storage ........................................................................................10
4 OPERATION AND INSTALLATION ...................................... 11
Preparing the Concentrator ....................................................... 11
Turning the Concentrator On .....................................................12
Turning the Concentrator Off..................................................... 12
5 MAINTENANCE .................................................................... 13
Cleaning the Cabinet .................................................................. 13
Cleaning or Replacing the Filters (3 Types) .............................. 13
Cleaning the Optional Humidier Bottle ................................... 15
Replacing the Battery ................................................................. 15
6 TROUBLESHOOTING GUIDE .............................................. 16
7 BILL OF MATERIALS ...........................................................
Replacement Parts and Optional Accessories ........................ 18
18
8 SPECIFICATIONS ................................................................. 19
Normal Operation Conditions .................................................... 19
9 LIMITED WARRANTY ......................................................... 20
10 INDEX.................................................................................... 22
11 PRODUCT REGISTRATION ................................................
24
All specications and product congurations are subject to change without notication.
2 John Bunn O2 Premier Oxygen Concentrator
Federal Law (USA) restricts this device to sale by or on the order of a physician. This product should not be used unless the operator has been instructed by a qualified health care professional.
WARNING: Users who require continuous oxygenation must plan for alternate reserve sources of power and oxygen in the event of a failure or loss of power and oxygen. This device is to be used ONLY as an oxygen supplement device and is NOT intended to be a life­supporting or life-sustaining device.
1 SAFETY
The John Bunn O2 Premier oxygen concentrator is intend­ed for use as an oxygen supplement device in a home or care facility. Use the concentrator only as prescribed by a physician. This user manual serves as a reference for your oxygen concentrator.
Important Information
Please note the following special statements, used throughout this manual, and their signicance:
Note: Explanatory information.
Damage: Action could result in damage to equipment.
s
ATTENTION: Action could result in personal injury.
CAUTION: Action could result in electric shock.
WARNING: Action could result in fire and explosion.
Before Installation
Damage: During transport, always keep the concentrator
s
upright to prevent damage.
Damage: Only use stable and safe electrical power
s
sources.
3John Bunn O2 Premier Oxygen Concentrator
Damage: If the electrical power source becomes
s
unstable, discontinue use and find an alternate source.
Damage: The oxygen concentrator cabinet contains no
s
serviceable parts! The oxygen concentrator cabinet should ONLY be opened by an authorized equipment provider.
Placement
ATTENTION: The oxygen concentrator is intended to be rolled from room to room. Do not place the oxygen concentrator in surroundings where its airflow is obstructed.
ATTENTION: Be certain to place the unit so that all sides are at least 12 inches (30 cm) away from walls, draperies, furniture, or other obstructions. Do not place the unit in a confined area.
ATTENTION: The oxygen concentrator MUST be kept away from heat, fire and excessive water sources and conditions.
ATTENTION: Do not place items on top of the concentrator.
ATTENTION: NEVER block the concentrator’s air openings.
ATTENTION: Always place the concentrator on a hard surface. Never place the concentrator on a surface such as bed or couch, where the concentrator may tip or fall.
ATTENTION: Keep the concentrator openings free from lint, hair, etc.
Fire Warning & Explosion
WARNING: Keep the concentrator away from flammable and explosive areas.
4 John Bunn O2 Premier Oxygen Concentrator
WARNING: To reduce the risk of fire, special care must be taken when using oxygen concentrators. DO NOT SMOKE while using this device. Keep all matches, lighted cigarettes or other sources of ignition out of the room in which this concentrator is located. In public settings or when used in hospital or long-term care environments, prominently display NO SMOKING signs.
WARNING: Textiles and other materials that normally would not easily burn, can ignite and burn with great intensity in oxygen enriched air.
WARNING: A spontaneous and violent ignition may occur if oil, grease or greasy substances come in contact with oxygen under pressure. ALWAYS keep these substances away from the oxygen concentrator and all other oxygen equipment. DO NOT use any lubricants unless recommended by manufacturer.
WARNING: Failure to observe these warnings can result in severe fire, property damage and cause physical injury or DEATH.
Maintenance
CAUTION: The oxygen concentrator was specifically designed to minimize routine preventive maintenance. Only an authorized equipment provider or factory-trained personnel should perform preventive maintenance or adjustments to the oxygen concentrator.
Radio Frequency Interference
Most electronic equipment is inuenced by Radio Fre­quency Interference (RFI). ALWAYS exercise CAUTION with regard to the use of portable communications equipment in the area around such equipment.
5John Bunn O2 Premier Oxygen Concentrator
Additional Safety Warnings
WARNING: TO REDUCE THE RISK OF BURNS, ELECTROCUTION, FIRE OR INJURY TO PERSONS, avoid using while bathing. If continuous usage is required by the direction of a physician, the concentrator must be located in another room at least 9 feet (2.8m) from the bath.
WARNING: DO NOT reach for a concentrator that has fallen into water. UNPLUG IT IMMEDIATELY.
WARNING: In certain circumstances, oxygen therapy can be hazardous. Graham-Field recommends that you seek medical advice before using this product.
WARNING: Avoid creation of any spark near medical oxygen equipment. This includes sparks from static electricity created by any type of friction.
ATTENTION: DO NOT come in contact with the concentrator when you are wet.
ATTENTION: DO NOT place or store the concentrator where it can drop into water or other liquid.
ATTENTION: NEVER leave the concentrator unattended when plugged in.
ATTENTION: This device is to be used only in accordance with the prescription of a physician and this user manual. If at any time the patient or attendant concludes that the patient is receiving an insufficient amount of oxygen, contact the provider and/or physician immediately. NEVER make adjustments to the flow rate unless prescribed by a physician.
6 John Bunn O2 Premier Oxygen Concentrator
ATTENTION: ALWAYS supervise closely when this product is used near children or those who require close supervision.
ATTENTION: Only use this device as intended and described in this manual.
ATTENTION: DO NOT use parts, accessories or adapters other than those authorized by manufacturer.
ATTENTION: DO NOT connect the concentrator in parallel or series with other oxygen concentrators or oxygen therapy devices.
ATTENTION: JB0160-015B, JB0160-015, JB0160-015B-220 and JB0160-015-220 only: Discontinue concentrator use immediately if O2 sensor red warning light illuminates; oxygen concentration is too low for safe use. Contact your Graham-Field equipment provider immediately.
7John Bunn O2 Premier Oxygen Concentrator
2 FEATURES
Summary
The John Bunn O2 Premier oxygen concentrator is intend­ed for use as an oxygen supplement device in a home or care facility. Use the concentrator only as prescribed by a physician.
The concentrator separates oxygen from ambient air, providing the user a high concentration of oxygen. Oxygen concentrator usage is therapeutically equivalent to other types of oxygen delivery systems.
Characteristics
• Reliable, safe, complete plastic outer shell.
• Display screen shows total elapsed working hours.
• Pressure safety valve helps ensure operating pressure.
• Power loss alarm function.
• High and low pressure alarm function.
• Heat protection to ensure the safety of the compressor and concentrator.
• JB0160-015B, JB0160-015, JB0160-015B-220, and JB0160-015-220 only: O2 sensor (electro-chemical de­vice): Yellow fault light illuminates when O2 concen­tration is greater than 71% and less than 82%; system works. Red warning light illuminates when O2 concen­tration is less than 71%; system shuts off.
8 John Bunn O2 Premier Oxygen Concentrator
3 HANDLING
GF Health Products, Inc. Freight Policy For Your Protection, Read Carefully
The carrier accepted this merchandise “in good condition” and is responsible for safe delivery.
Before signing the freight bill, inspect the shipment care­fully for damage or missing pieces.
Apparent Loss or Damage
Should visual inspection show loss or damage, this MUST be noted on the freight bill and signed by the carrier’s agent. Failure to do so may result in the carrier failing to honor the claim. Please contact the carrier to obtain the paperwork necessary to le a claim.
Concealed Loss or Damage
If damage is discovered after delivery is made, a concealed damage claim must be entered with the freight carrier. When this occurs, make a written request to the carrier for inspection. This request for inspection must be made within 15 days of delivery. The carrier will provide all paperwork necessary to le a concealed damage or loss claim, since such damage or loss is the carrier’s responsi­bility.
Unpacking
Note: Unless the oxygen concentrator is to be used
immediately, retain containers and packing materials for storage until concentrator use is required.
1. Check for obvious damage to the carton or its contents. If damage is evident, please notify the carrier and your Graham-Field equipment provider.
2. Remove all loose packing from the carton.
3. Carefully remove all the components from the carton.
9John Bunn O2 Premier Oxygen Concentrator
Inspection
Examine exterior of the oxygen concentrator for nicks, dents, scratches or other damages. Inspect all compo­nents.
Storage
Store the repackaged oxygen concentrator in a dry area. DO NOT place anything on top of the repackaged concen­trator.
10 John Bunn O2 Premier Oxygen Concentrator
4 OPERATION AND INSTALLATION
Preparing the Concentrator (refer to above picture)
1. Unscrew the humidier bottle cover, if so equipped (hu­midier bottle is optional).
2. Fill the humidier bottle with puried water (or dis­tilled water) between the maximum and minimum water level lines. If needed, add medication to the water, as prescribed by physician.
3. Screw the cover back on the humidier bottle.
4. Screw the humidier bottle adapter into the humidier bottle cover.
5. Insert the humidier bottle into the elastic belt on the left side of the unit.
6. Connect the other end of the oxygen hose to the oxygen outlet.
7. Ensure that the power switch is off; plug the concen-
11John Bunn O2 Premier Oxygen Concentrator
trator’s AC connector into a properly grounded power outlet.
Turning the Concentrator On
1. Press the power switch to start the concentrator. There will be a brief delay before the concentrator starts. The alarm system emits a tone of one second duration, the word HELLO appears on the hour meter LED panel, and the green power indicator light illuminates.
ATTENTION: Every time the concentrator starts, the alarm system performs a self test, and emits a brief tone. If the alarm does anything other than emit a brief tone, see Section 6, Troubleshooting Guide, and follow the appropriate steps.
2. Turn the owmeter knob to the setting prescribed by your physician or therapist.
Note: To properly read the flowmeter, locate the prescribed
flowrate line on the flowmeter.
3. Turn the owmeter knob until the owmeter ball rises to the appropriate line.
4. Center the owmeter ball on the L/min line prescribed.
Damage: If the flowrate on the flowmeter ever falls below
s
0.5L/min, check tubing or accessories for blocked or kinked tubing or for a defective humidifier bottle.
If using a humidier bottle, the oxygen comes from the humidier bottle outlet.
5. Connect the oxygen tubing barb connector securely to the humidier outlet; the other end of the oxygen tub­ing is used by the patient.
Note: Oxygenation times and the flowrate ranges are
established and prescribed by your physician.
Turning the Concentrator Off
Turn off the power switch and unplug the concentrator’s AC connector from the power outlet.
12 John Bunn O2 Premier Oxygen Concentrator
5 MAINTENANCE
Cleaning the Cabinet
Clean the cabinet at least once a month.
1. Turn off the power switch.
2. Clean the cabinet with a mild household cleaner and a non-abrasive cloth or sponge. Do not spill liquid inside the cabinet.
Cleaning or Replacing the Filters (3 Types)
Clean or replace the lters as often as specied in the following paragraphs in order to protect the compressor and extend the concentrator’s life. Replacement lters are available from your Graham-Field equipment provider.
Bottom filter
The bottom lter does not typically require cleaning, but it may if operated in extremely dirty conditions. Perform a visual inspection of the bottom lter every 2 weeks; if the lter is dirty, clean it. The bottom lter is located at the bottom rear of the cabinet (see Figure 1). To clean:
1. Remove the bottom lter from the squares carefully with your ngers.
2. Inspect the lter; if any part of it is cracked or broken, replace it instead of clean­ing it.
3. If cleaning, rinse lter well with clear water until all dirt is removed.
4. Dry lter by squeezing between two absorbent towels. Wait for filter to dry. When dry, install lter carefully as shown in Figure 1.
Damage: Do not operate the concentrator without the
s
filters installed, or while filters are wet. These actions could permanently damage the concentrator.
13John Bunn O2 Premier Oxygen Concentrator
Side filters
Note: For earlier models only, you will need a small blade
screwdriver to open the side filter access door. For later models, the filter grill simply pulls out. If this operation is too difficult for you to perform, please contact your equipment provider to perform this for you.
Clean the side lters weekly. There are two side lters, one located on each side of the concentrator cabinet. Perform the following steps on both side lters.
1. Turn off the power switch and unplug the concentra­tor’s AC connector from the power outlet.
2. For earlier models, use a small blade screwdriver to open the air intake ac­cess door; for later mod­els, open the lter grill (see Figure 2).
3. Remove the side lter carefully with your n­gers.
4. Inspect the lter; if any part of it is cracked or broken, replace it instead of cleaning it.
5. If cleaning, rinse lter well with clear water until all dirt is removed.
6. To dry lter, squeeze it carefully between two absor­bent towels . Wait for filter to dry before installing it in concentrator. When dry, install lter carefully as shown in Figure 2.
Damage: Do not operate the concentrator without the
s
filters installed, or while filters are wet. These actions could permanently damage the concentrator.
Damage: Please note that the side filters may require
s
cleaning more often, especially if the concentrator is operated where the following conditions exist:
14 John Bunn O2 Premier Oxygen Concentrator
• A wood stove is used
• Kerosene or oil is used
• Pets are present
• Tobacco is used
Intake filter
Note: Please have your Graham-Field equipment provider
replace the intake filter. This operation requires opening the intake filter access door.
Replace, do not clean, the intake lter annually (or more often, if the intake lter turns black). The frequency of re­placement depends on usage and condition of the environ­ment where the concentrator is used.
Cleaning the Optional Humidier Bottle
Change the water in the humidier bottle every day. Wash the humidier bottle weekly with warm soapy water, rinse with a solution of 1 part vinegar to 10 parts water, and rinse thoroughly with hot water before relling.
Replacing the Battery
Note: Please have your Graham-Field equipment provider
replace the battery. This operation requires opening the battery access door.
Note This device uses a 9V battery. If the concentrator will
not be used for an extended period, please have your Graham-Field equipment provider remove the battery.
When the battery becomes weak, the alarm will sound. Have your Graham-Field equipment provider change the battery immediately.
ATTENTION: Without the battery, the alarm will not work. ALWAYS change the battery when necessary.
15John Bunn O2 Premier Oxygen Concentrator
6 TROUBLESHOOTING GUIDE
SYMPTOM CHECK / ACTION
Concentrator power is Check if concentrator is unplugged; plug in. on and alarm is on, but concentrator doesn’t Check if circuit breaker is tripped; x circuit work breaker.
If concentrator still doesn’t work, contact Graham-Field equipment provider.
SYMPTOM CHECK / ACTION
Concentrator works, Inspect tubes and cannula to ensure that they are but little or no oxygen not kinked or blocked. Smooth tubes to unblock. from outlet
Check humidier bottle, if so equipped, for leaks or jamming. Give humidier bottle a slight shake to open safety valve. Clean humidier bottle,
reinstall and tighten.
If condition persists, contact Graham-Field equipment provider.
SYMPTOM CHECK / ACTION
Flowmeter ball located Adjust owmeter knob. If condition persists, on “0” position or oat contact Graham-Field equipment provider.
is unstable
SYMPTOM CHECK / ACTION
Concentrator works, If yellow light blinks, and alarm sounds at low but makes abnormal intervals, or yellow light illuminates continuously sound and alarm sounds, contact Graham-Field equipment provider.
SYMPTOM CHECK / ACTION
Concentrator works, OK to continue use, but contact Graham-Field but yellow fault light equipment provider immediately. Concentrator’s lluminates oxygen concentration is safe, but decreasing. (JB0160-015B, When oxygen concentration is too low for safe JB0160-015, use, concentrator will shut off and optional O2 JB0160-015B-220, sensor red warning light will illuminate. JB0160-015-220 only)
16 John Bunn O2 Premier Oxygen Concentrator
SYMPTOM CHECK / ACTION
Concentrator doesn’t Discontinue use; contact Graham-Field equipment work; alarm sounds; provider immediately. Oxygen concentration is too optional O warning light illuminates (JB0160-015B, JB0160-015, JB0160-015B-220, JB0160-015-220 only)
sensor red low for safe use.
2
Note: If you experience a problem with your concentrator
and are unable to service it yourself, contact the equipment provider from whom you purchased the concentrator. If the equipment provider is unable to help you, contact Graham-Field’s Customer Service Department at 800-347-5678.
17John Bunn O2 Premier Oxygen Concentrator
7 BILL OF MATERIALS
Your concentrator includes the following components:
• Oxygen concentrator (one each)
• User manual (one each)
• Humidier bottle hose (one each)
• Humidier bottle adapter (one each)
The concentrator comes with one bottom lter, two side lters, and one intake lter already installed; Model Nos. JB0160-015B, JB0160-015, JB0160-015B-220 and JB0160-015-220 come with one O2 sensor already installed.
Replacement Parts and Optional Accessories
Replacement parts and optional accessories are available for your concentrator. Please contact your Graham-Field equipment provider to order replacement parts and/or ac­cessories.
For a list of available replacement parts and optional ac­cessories, please visit www.grahamfield.com
18 John Bunn O2 Premier Oxygen Concentrator
8 SPECIFICATIONS
• Flow Range: 1 to 5L/min
• Oxygen Concentration: 1-4 LPM 94% ± 2%
5 LPM 92% ± 2%
• Maximum Outlet Pressure: 6.52 psi ± .065 psi
(45kPa ± 4.5kPa)
• Pressure Relief Mechanism Operational at:
36.26 psi ± 3.63 psi (250kPa ± 25kPa)
• Altitude: Up to 5,997 feet (1,828 meters) above sea level
without degradation of concentration levels. Efciency of 90% from 5,997 to 13,123 feet (1,828 to 4,000 meters) above sea level.
• Sound Level: ≤ 55dB
• Power Supply: JB0160-010B, JB0160-010, JB0160-015B,
JB0160-015: AC120V±10% (60Hz) (4.6amps).
JB0160-010B-220, JB0160-010-220, JB0160-015B-220,
JB0160-015-220: AC220V±10% (50Hz) (2.2amps)
• Input Power: 400 Watts Average
• Weight: 57lbs (26kg)
• Dimensions: H 27” x W 18” x D 15”
• Minimum Warm-Up Time Before Use: 30 minutes
• Electrical Classication: II Class B Type
• System: Continuous
• JB0160-015B, JB0160-015, JB0160-015B-220,
JB0160-015-220 only: O2 sensor (electro-chemical de­vice): Yellow fault light illuminates when O2 concen­tration is greater than 71% and less than 82%; system works. Red warning light illuminates when O2 concentra­tion is less than 71%; system shuts off.
Normal Operation Conditions
• Temperature range: 41°F to 104°F (5°C to 40°C)
• Relative humidity: 20% to 60%
• Atmospheric pressure: 12.47 psi to 15.37 psi
(86kPa to 106kPa)
19John Bunn O2 Premier Oxygen Concentrator
9 LIMITED WARRANTY
This warranty is extended only to the original purchaser of our products. This warranty gives you specic legal rights and you may also have other legal rights which may vary from state to state. GF Health Products, Inc. warrants its John Bunn O2 Premier Oxygen Concentrator to be free from defects in materials and workmanship from the date of pur­chase for the following time period:
Compressor: six (6) years Balance of concentrator: ve (5) years
Removal of the concentrator cover, unauthorized attempts to service the unit or unauthorized replacement of parts, other than routine maintenance, as described in this user manual, will void all warranties applicable to this concentrator device.
If within such warranty period any such product shall be proven to GF Health Products, Inc.’s satisfaction to be defec­tive, such product shall be repaired or replaced, at GF Health Products, Inc.’s option. This warranty only applies to the labor for repairs performed by the authorized Equipment Pro­viders. It does not apply to the labor performed by the pur­chaser or user. This warranty does not include normal wear and tear or shipping charges. GF Health Products, Inc.’s sole obligation and your exclusive remedy under this warranty shall be limited to such repair or replacement.
Routine maintenance items, such as lters, are excluded from this warranty. For warranty service, please contact GF Health Products, Inc.’s Customer Service. Upon receiving notice of an alleged defect in a product, GF Health Products, Inc. will issue a serialized return authorization. It shall then be the responsibility of the purchaser to return the entire unit or remove, at purchaser’s cost, the defective component part(s) identied, pack the component part(s) in a manner to avoid shipping damage and to ship the component part(s) to either GF Health Products, Inc. or an Authorized Equipment Provid­er, as specied by GF Health Products, Inc. in advance.
Defective component part(s) must be returned for warranty inspection, using the serialized return authorization number
20 John Bunn O2 Premier Oxygen Concentrator
as identication, within thirty (30) days of the return autho­rization date. Do not return products to GF Health Products, Inc. or its Authorized Equipment Providers, without prior consent. C.O.D. shipments will be refused. All return ship­ments must prepay shipping charges, unless otherwise au­thorized by GF Health Products, Inc.
Concentrator warranty for the John Bunn O2 Premier Oxy­gen Concentrator (part numbers JB0160-010B, JB0160-010, JB0160-010B-220, JB0160-010-220, JB0160-015B, JB0160-015, JB0160-015B-220, JB0160-015-220) limitations and exclusions:
The foregoing warranty shall not apply to products subjected to negligence; accident; improper operation, maintenance or storage; soot or smoke-lled environments; other than normal application, use or service; modication without GF Health Products, Inc.’s express written consent (including, but not limited to, modication through the use of unauthor­ized parts or attachments); damage by reason of repairs made to any component without the specic consent of GF Health Products, Inc.; or to products damaged by circum­stances beyond GF Health Products, Inc.’s control.
The foregoing express warranty is exclusive and in lieu of any other warranties whatsoever, whether express or implied, in­cluding the implied warranties of merchantability and tness for a particular purpose; and the sole remedy for violations of any warranty whatsoever shall be limited to repair or replace­ment of the defective product pursuant to the terms con­tained herein. The application of any implied warranty what­soever shall not extend beyond the duration of the express warranty provided herein. GF Health Products, Inc. shall not be liable for any consequential or incidental damages whatso­ever. Some states do not allow the exclusion or limitation of incidental or consequential damage, or limitation of how long an implied warranty lasts, so the above exclusion and limita­tion may not apply to you. This warranty shall be extended to comply with state/provincial laws and requirements.
Note: The above warranty has been written to comply with
Federal Law applicable to products manufactured after July 4, 1975.
21John Bunn O2 Premier Oxygen Concentrator
10 INDEX
A
ATTENTION, signicance 3
B
Before installation, safety 3 Bill of materials 18
C
CAUTION, signicance 3 Cleaning the cabinet 13
D
Damage, signicance 3, 14
F
Features 8 Filters, cleaning or replacing
13
Fire warning & explosion,
safety 4
Freight policy, Graham-Field’s
9
H
Handling 9
I
Inspection 10
R
Radio Frequency Interference
(RFI) 5
Replacement parts and op-
tional accessories 18
Replacing the battery 15
S
Safety 3 Safety warnings, additional 6 Specications 19 Storage 10
T
Troubleshooting guide 16 Turning the concentrator off
12
Turning the concentrator on
12
U
Unpacking 9
W
WARNING, signicance 3 Warranty, limited 20
M
Maintenance 13 Maintenance, safety 5
N
Note, signicance 3
O
Operation and installation 11
P
Placement, safety 4 Preparing the concentrator 11
22 John Bunn O2 Premier Oxygen Concentrator
NOTES
23John Bunn O2 Premier Oxygen Concentrator
REGISTER
®
YOUR PRODUCT!
The benets of registering:
• Safeguard your investment.
• Ensure long-term maintenance and servicing of your purchase.
• Receive updates with product information, mainte­nance tips, and industry news.
• GF Health Products, Inc. can contact your or your pro­vider, if servicing is needed on your product.
• It will enable GF Health Products, Inc. to improve prod­uct designs based on your input and needs.
To register your product:
• Complete the form and questionnaire on the next page.
• Cut out the page on the dotted line.
• Fold the page along the middle with the questionnaire on the inside, and the address on the outside.
• Fill out your return address.
• Afx rst-class postage.
• Mail to Graham-Field Health Products. Thank you!
24 John Bunn O2 Premier Oxygen Concentrator
QUESTIONNAIRE
1. Method of purchase: (check all that apply)
Medicare Insurance Medicaid Other
2. This product was purchased for use by: (check one)
Self Parent Spouse Other
3. This product was purchased for use at:
Home Facility Other
4. I purchased a Graham-Field product because:
Price Features (list features) Other
5. Who referred you to Graham-Field products? (check all that apply)
Doctor Therapist Friend Relative Dealer/Provider Other Advertisement (circle one): TV, Radio, Magazine, Newspaper No Referral
6. What additional features, if any, would you like to see on this
product?
7. Would you like to receive information about Graham-Field products
that may be available for a particular medical condition?
Yes �No
If yes, please list any condition(s) here and we will send you
information by email and/or regular mail about any available Graham-Field products that may help treat, care for or manage such condition(s):
8. Would you like to receive updated information via email or regular
mail about Graham-Field home medical products? Yes No
9. What would you like to see on the Graham-Field website?
10. Would you like to be part of future surveys for Graham-Field
products? Yes No
11. User’s year of birth:_______________
If at any time you wish not to receive future mailings from us, please contact us at GF Health Products, Inc., 2935 Northeast Parkway, Atlanta, GA 30360, 800-347-5678
To find more information about our products, visit www.grahamfield.com
Affix
first-class
postage
here
GF Health Products, Inc. 2935 Northeast Parkway Atlanta, GA 30360
USA, Corporate Headquarters:
Graham-Field Health Products
2935 Northeast Parkway
Atlanta, Georgia 30360
telephone: 800-347-5678, 770-447-1609
fax: 800-726-0601, 678-291-3232
http://www.grahamfield.com
GF0600004RevH07
©GF Health Products, Inc.
printed in China
John Bunn, O2 Premier, GF, and Graham-Field
are registered trademarks of GF Health Products, Inc.
Loading...