1. DECLARATION OF CONFORMITY
We www.plumbworld.co.uk declare that the Ultraflow Macerator product is following directives
The
Low
Voltage
EMC
Directive (Directive
CE
Marking
to
specification under which conformity is declared.
Directive
(Directive
89/336/EEC)
Directive (Directive
2006/95/EC)
98/37/
EC)
in
conformity with the
C>Grafton
Group
PLC Page 3
of
20
2. SPECIFICATION
Water temperature 1 degree centigrade (minimum) / 90 degrees
Voltage 220v-240v
Amperage
Motor Power
Thennal Safety Device 135 degrees centigrade
Discharge head
Capacitor
Water Ingress Protection
Flow rate
Maximum discharge height
Maximum discharge horizontal length
*Product compliant with standard EN 12050-3
tAllow see
at
a reduction
Fig
A for example.
pump output
of
0.5m per bend introduced,
centigrade (maximum)
3Amps
600Watts
6mws
10uF/450 Volts
IP
X4
270
litres/
minute
5.5
metrest
60
metrest
j
~
C>Grafton
Group
PLC
E
"'
0 -
@,
<I\
0
w
m
N
'
E
"?
"'
Fig A
i
:§,
..,
..c
~
E E
"?
.,,
II
l
~
.
!.Al
..,
..c
~
E E
"?
"'
1,
Page4of20
3.
SAFETY INSTRUCTIONS
Prior
to
installation
Ensure the entire contents
of
this instruction manual are read.
Ensure the package contains all component parts listed in this instruction manual.
Ensure the two check valves stored inside the rubber chamber
Ensure all packaging material is removed and disposed
of
correctly.
of
the
appliance are removed.
Installation
Electrical installation
of
the appliance must only be carried
out
by
a qualified person.
The appliance must be installed in accordance with the installation instructions specified in this document.
Always ensure the macerator is connected
to
mains power before water enters the unit.
Prior to use
Before using the macerator, clean water must be flushed through
the
appliance several
times. This will ensure the macerator is correctly installed.
Daily use
The appliance
The appliance
toilet paper only. Failure
Products not
is
suitable for domestic, indoor use only.
is
suitable for the discharge
to
comply with this will invalidate the warranty.
to
be
discharged using the appliance include but are not exclusive to: kitchen
of
domestic faecal matter, waste water and
towels, wet wipes, cotton wool, condoms and sanitary towels.
Servicing and maintenance
Before servicing the appliance, always ensure the electrical supply
Troubleshooting, maintenance and servicing person who
is
competent to do so.
of
the appliance must only be carried out by a
is
fully disconnected.
To maintain optimum performance, it is recommended that the appliance is serviced and cleaned at least once every 6 months.
For
hygiene reasons, rubber gloves should be worn at all times when servicing the
appliance.
WARNING: This appliance must only be used with a 32mm
the soil stack. It is not suitable for use with 22mm incorrectly sized waste
C>Grafton
Group
PLC Page
may
result in a leaking unit.
or
25mm pipework. Using the macerator with an
or
40mm waste pipe from the outlet to
5of20
INVALIDATION OF WARRANTY
Please
note that any
one
of
the
following
situations will invalidate the product warranty:
Failure to install the appliance
in
accordance with the installation instructions contained
this document.
Electrical installation of the appliance
Discharge of materials other than
faecal
appliance.
Failure to carry
out
regular maintenance
instructions.
4. PRODUCT DESCRIPTION
The
Ultraflow Macerator is designed for the purposes
waste, waste water It is compatible for
and
use
with a
toilet paper
maximum
in
accordance with the relevant regulations.
of three
1 x basin
1 x shower
1 x toilet
OR
it can
be
used
1 X
to discharge waste
bath
from
1 x kitchen sink
1 x
washing
machine
by
an
unqualified
matter, waste water
and
servicing of the appliance as detailed
bathroom
any
one
person
and
of
discharging
items, including:
of the following:
.
toilet paper through
normal
in
domestic faecal
in
the
these
1 x dishwasher
C>Grafton
Group
PLC Page
6of20
5. OPERATING PRINCIPLE
The
macerator comprises a tank that holds waste
The
pump
is controlled
discharge action is triggered
by
an
automatic
when
the
pressure
flushing
before
switch
system
it
is
discharged,
and
an
electric
. As with a conventional toilet, the
is actuated.
pump
.
Domestic
The pressure switch
The
Domestic
CONTROL COMPONENTS:
D -
Pressure
waste
is
air chamber
(B)
(D)
pressure switch
waste
is
Switch
collected
records the air
.
(D)
discharged through
in
the tank
pressure
trips the motor (
(A)
.
E).
the
outlet (G).
flowing
through
The
motor drives the turbine
the
outlet pipe (C)
(F)
to
the
.
MECHANISM COMPONENTS:
E - Electric Motor F-Turbine
CONTROL COMPONENTS AND SAFETY DEVICES:
G -
Check
Valve
H -
Manual
C>Grafton
Override
Group
Switch