SPECIFICATION SUBMITTAL
Preset Dimming Controls
GXI-3000
Description
• Provides pushbutton recall of four preset lighting scenes, plus Off.
• Allows setup of lighting scenes using buttons on the Control Unit.
• Controls virtually any light source without an interface.
• Provides lockout options to prevent accidental changes.
• Includes built-in infrared receiver for operation with an optional remote control.
Models available to:
• Accept 230V (CE) input power.
• Control four zones of lighting.
GXI-3100 Control Unit allows setup of lighting scenes using buttons on the Control Unit. GXI-3500 Control Unit allows setup of lighting scenes using a PC, including setting lighting levels in 1% increments.
GXI-3000 Control Unit
Cover (shown open)
Infrared Receiver Scene Selection
Buttons
Zone
Base
R
Job Name:
Job Number:
Model Numbers:
Page
SPECIFICATION SUBMITTAL
Preset Dimming Controls
GXI-3000
Key Design Features
• Meets IEC 801-2. Tested to withstand 15kV electrostatic discharge without damage or memory loss.
• Provides over-current and short-circuit protection.
• Provides capability to trim High End and Low End.
• Manual or automatic selection between leading edge or trailing edge dimming for low voltage transformers.
• Provides air gap isolation when the Off scene is selected.
• 10-year power failure memory automatically restores lighting to levels prior to power interruption.
• Faceplate snaps on with no visible means of attachment.
System Communications and Capacities
• Low-voltage type PELV wiring connects Control Units, Wallstations, and Control Interfaces.
• Up to 8 Control Units may be linked to control up to 32 zones.
• Up to 16 total Wallstations and Control Interfaces may be added for a total of 24 control points.
Environment
• 0-40°C. Relative humidity less than 90% non-condensing.
Input Power
• 230V (CE), 50Hz.
• Lightning Strike Protection: Can withstand voltage surges of up to 6000V and current surges up to 3000A.
Sources/Load Types
Controls the following lighting sources with a smooth, continuous Square Law dimming curve or on a full conduction non-dim basis:
• Incandescent
• Electronic Low Voltage
• Magnetic Low Voltage
• 0-10V and DSI* ballasts; DALI - intensity
broadcast only
• Neon and Cold Cathode
Preset Controls
• 4 preset lighting scenes and off are accessible from the Control Unit front panel.
• 12 additional scenes are stored in the Control Unit. These scenes are accessible via Wallstations and/or Control Interfaces.
• Light levels fade smoothly between scenes. Fade time can be set differently for each scene, between 0-59 sec. or 1-60 min. Fade time from Off is capped at 5 sec.
Specifications
R
Job Name:
Job Number:
Model Numbers:
Page
SPECIFICATION SUBMITTAL
Preset Dimming Controls
GXI-3000
Number of Zones
Unit Capacity
Zone Capacity
Dimmed/Switched Live Output
Ballast Control Output
Model Number
Model Number
230V (CE) Input Power
4
GXI-3104-_-CE-__
2300W/VA
800W/VA
Up to 20 Ballasts
G X I - 3 1 0 4 - T - C E - W H
Prefix
Number of Zones
Input Voltage
Set-Up Method
Cover Option
Color Option
Color Options
Architectural Matte Finishes
Standard – Ship in 48 hours Cover Option: A or T White WH Ivory IV Beige BE Gray GR Brown BR Black BL
Designer Gloss Finishes
Ship in 4 to 6 weeks Cover Option: A only White GWH Light Almond GLA Almond GAL Ivory GIV
Satin Color Matte Finishes
Cover Option: A or T Hot HT Ochre OC Terracotta TC Desert Stone DS Stone ST Limestone LS Blue Mist BT Midnight MN Taupe TP Biscuit BI Eggshell ES Snow SW
Architectural Metal Finishes
Cover Option: T only Bright Brass BB Bright Chrome BC Satin Brass SB Satin Chrome SC Satin Nickel SN Antique Brass QB Antique Bronze QZ Bright Nickel BN
Anodized Aluminum Finishes
Cover Option: T only Clear CLA Black BLA Brass BRA Bronze BZA
Cover Options
Opaque A Cover and Base will match.
Translucent Black T
Black Cover and choice of base color.
Also available:
- Custom controls
- Color matching
- Engraving
These options ship in 4 to 6 weeks
How to Build a Model Number
Prefix:
GXI for GRAFIK Integrale 3000 Series
Control Units
Set-Up Method:
1 for standard setup via front panel 5 for PC setup
Number of Zones:
4
Cover Option:
A for Opaque T for Translucent Black
Input Voltage
CE for 230V (CE)
Color Option:
See Color Options list
4
GXI-3504-_-CE-__
2300W/VA
800W/VA
Up to 20 Ballasts
R
Job Name:
Job Number:
Model Numbers:
Page
SPECIFICATION SUBMITTAL
Preset Dimming Controls
GXI-3000
84mm
76mm
Dimensions and Mounting
Side View
Backbox Front Views
8mm
49mm
116mm
73mm
200mm
95mm
Lutron P/N 241-400
Lutron P/N 241-691 (old-work backbox)
208mm
138mm
227mm
R
Job Name:
Job Number:
Model Numbers:
Page
SPECIFICATION SUBMITTAL
Preset Dimming Controls
GXI-3000
Consult Lutron for:
• Non-dim relay wiring.
• Load side emergency transfer wiring.
Pull power wiring from distribution panel and to light fixtures. Each line voltage terminal can accept up to two 2.5mm2wires. For phase-to-neutral wiring, connect one phase to Live and the other phase to Neutral. When wired phase-to-phase, the air gap does not break both phases while the Control Unit is Off: the MCB(s) must be turned off when servicing the Control Unit or associated loads.
Distribution Panel
Control Unit
Control Interface
Wallstations
Power Supply
Rear View of GXI-3104 Control Unit
0-10V and DSI Ballast Wiring
Hot/Live
Earth/
Ground
Load 1
Load 2
Load 3
Load 4 - Ballast
(2)
2.5mm
2
(2) 2.5mm
2
(2) 1.0mm
2
(2) 2.5mm
2
Neutral
230V (CE) Mains Voltage Wiring
Low-Voltage PELV Wiring
• System communications use low-voltage PELV (Class 2) wiring.
• Wiring must be daisy-chained.
• Wiring must run separately from line (mains) voltage.
External 12VDC Power Supply is required to power more than three Wallstations and/or Control Interfaces from a single Control Unit.
PELV (Class 2) wiring link requires: Two 2.5mm2(#12 AWG) conductors for control power. One twisted, shielded pair of 0.625mm2 (#18 AWG) for data link.
Total length of Control Link may be up to 610m (2,000 ft.). Approved low-voltage cable is available from Lutron
1
, Belden, and Liberty.
These are approved with #22 AWG data link wires.
GRX-CBL-346S PELV (Class 2) wiring cable is available from Lutron and contains: Two 2.5mm
2
(#12 AWG) conductors for control power.
One twisted, shielded pair of 0.625mm
2
(#22 AWG) for data link.
1
Hot/Live Neutral
PELV ONLY
1 2 3 4
Ballast Control Outputs
Zone 1
Zone 2
}
}
+-
Zone 4
Zone 3
}
}
+-
+-+-
+
-
DL/SL 1 DL/SL 2 DL/SL 3 DL/SL 4
R
Job Name:
Job Number:
Model Numbers:
Page
SPECIFICATION SUBMITTAL
Preset Dimming Controls
GXI-3000
PELV Terminal Connections
• Each PELV terminal accepts up to two 1.0mm2wires.
• Daisy chain the terminal 1, 3, and 4 connections to all Control Units, Wallstations, and Control Interfaces.
• Each Control Unit has its own power supply. Terminate the terminal 2 connection (12VDC power) so that each Control Unit supplies power to a maximum of three Wallstations. Each Wallstation should receive power from only one Control Unit.
• Make all connections in the Control Unit’s wallbox. Remote connections must be in a switchbox or junction box with a maximum wire length of 2.5m from the link to the connected unit.
• Do not allow PELV wires to contact line/mains wires.
Rear View of GXI-3000 Control Unit
A3 powers Wallstations 2, 3, and 4 – no terminal No. 2 connection between Wallstations 4 and 5
A1 powers 1 only – terminal No. 2 connection terminates at Wallstation 1
A2 and A3 have their own power supplies – no terminal No. 2 connection
Lutron Cable, GRX-CBL-346S
Note:
• Up to 8 GXI-3000 Series Control Units and 16 Wallstations/Control Interfaces may be
daisy-chained together in one system.
• PELV/Class 2 cable is available from Lutron - order GRX-CBL-346S.
A4 powers Wallstations 5, 6, and 7 – no terminal No. 2 connection between Wallstations 4 and 5
Rear View of GXI-3000 Control Unit
Rear View of GXI-3000 Control Unit
Rear View of GXI-3000 Control Unit
PELV ONLY
1234
A3
A1
PELV ONLY
1234
1
4 3 2
4 3 2 1
1
4321
PELV ONLY
A2
2
4 3 2
4 3 2 1
1
3
4 3 2
4 3 2 1
1
4
4 3 2
4 3 2 1
1
5
4 3 2 1
6
4 3 2 1
7
4 3 2 1
A4
4321
PELV ONLY