Job Name:
Job Number:
Model Numbers:
Page
SPECIFICATION SUBMITTAL
gxi-2 2.26.04
Preset Dimming Controls
GXI-3000
Key Design Features
• Meets IEC 801-2. Tested to withstand 15kV
electrostatic discharge without damage or
memory loss.
• Provides over-current and short-circuit
protection.
• Provides capability to trim High End and Low
End.
• Manual or automatic selection between
leading edge or trailing edge dimming for low
voltage transformers.
• Provides air gap isolation when the Off scene is
selected.
• 10-year power failure memory automatically
restores lighting to levels prior to power
interruption.
• Faceplate snaps on with no visible means of
attachment.
System Communications and Capacities
• Low-voltage type PELV wiring connects Control
Units, Wallstations, and Control Interfaces.
• Up to 8 Control Units may be linked to control up
to 32 zones.
• Up to 16 total Wallstations and Control Interfaces
may be added for a total of 24 control points.
Environment
• 0-40°C. Relative humidity less than 90%
non-condensing.
Input Power
• 230V (CE), 50Hz.
• Lightning Strike Protection:
Can withstand voltage surges of up to 6000V
and current surges up to 3000A.
Sources/Load Types
Controls the following lighting sources with a
smooth, continuous Square Law dimming curve
or on a full conduction non-dim basis:
• Incandescent
• Electronic Low Voltage
• Magnetic Low Voltage
• 0-10V and DSI* ballasts; DALI - intensity
broadcast only
• Neon and Cold Cathode
Preset Controls
• 4 preset lighting scenes and off are accessible from
the Control Unit front panel.
• 12 additional scenes are stored in the Control Unit.
These scenes are accessible via Wallstations and/or
Control Interfaces.
• Light levels fade smoothly between scenes. Fade
time can be set differently for each scene, between
0-59 sec. or 1-60 min. Fade time from Off is capped
at 5 sec.
Specifications