PLEASE NOTE: Read through these instructions
before beginning installation. It is important to follow the
steps described in these instruc­tions. Failing to follow these instructions will void any war­ranty on this product. Separate installation instructions will be shipped with any additional items you have purchased.
Keep this instruction manual and make it available for all end­users.
FAILURE TO COMPLY WITH THESE INSTRUCTIONS CAN RESULT IN SERIOUS PERSONAL UNJURY OR DEATH AND/OR SEVERE PROPERTY DAMAGE.
Watts is not responsible for any damages or injuries that result from improper installation and/or use.
700 gallons / 2700 litres Order No. 81011001
1000 gallons / 3750 litres Order No. 81011002
1250 gallons / 4800 litres Order No. 81011003
1700 gallons / 6500 litres Order No. 81010059
Check the tanks for possible damage before installing them into the excavation pit. The installation must be con­ducted by a qualified company.
Installation and maintenance instructions for Carat - S
series rainwater storage tank
distributed in the U.S. by
2 of 13
2. Installation / assembly conditions
WARNING
KEEP THIS INSTRUCTION MANUAL AND MAKE IT AVAILABLE FOR ALL END USERS
Read through these instructions before beginning installation. FAILURE TO COMPLY WITH THESE INSTRUCTIONS CAN RESULT IN SERIOUS PERSONAL INJURY OR DEATH AND/OR SEVERE PROPERTY DAMAGE. Watts is not responsi­ble for any damages or injuries that result from improper installation and/or use.
DO NOT USE RAINWATER COLLECTED WITH THIS EQUIPMENT FOR
POTABLE APPLICATIONS SUCH AS DRINKING, SHOWERING, OR COOKING unless you are using a filtration system specifically designed and approved for producing potable water from harvested rainwater. Water col­lected with this system should only be used to water outdoor plantings, wash vehicles, or use in other outdoor cleaning tasks. Water may be stag­nant or contaminated and can cause serious illness and/or death if in­gested.
When working on any electrical system and/or system components, the en-
tire system must be disabled by disconnecting it from any and all power sources to prevent an accidental restart.
Except in the event of work carried out in the tank, the cover of the tank
must always be kept sealed, as any other configuration presents a very high risk of accident. Only original equipment covers or covers approved in writ­ing by manufacturer may be used.
Separate installation instructions will be shipped with any additional manu-
facturer-approved items you have purchased. Consult those instructions before making additions to your rainwater collection system.
WARNING
1. Preliminary Considerations
3 of 13
Preliminary Considerations
ADDITIONAL WARNINGS
1.1 Safety Issues
All applicable federal, state, and local safety regulations should be observed
during assembly, installation, maintenance, and/or repair of this equipment. When inspecting tanks, we strongly recommend that a second person be present.
When inspecting tanks, particularly when standing on them, a 2nd person
must be present.
The installation of the system or any of its individual parts must be con-
ducted by qualified professionals.
The manufacturer offers a comprehensive portfolio of accessories that are
designed to work with each other and can be developed into complete sys­tems. Using unapproved components may cause the system to malfunction, in which case any existing warranties will not be applicable.
Wear safety glasses and gloves when drilling or cutting during this installa-
tion.
DO NOT ALLOW CHILDREN NEAR THE TANK BEFORE, DURING, OR AFTER INSTALLATION WITHOUT DIRECT SUPERVISION BY A COMPETENT PERSON.
1.2 Compulsory Labelling
All lines, connections, and outlets of water processed with this equipment must be
labelled with the words “UNTREATED RAINWATER: DO NOT DRINK” in writing or
graphically in order to avoid an accidental connection to the drinking water net­work even after years of use. Even when there are correct labels, mistakes are possible if children or other persons unfamiliar with the system are allowed ac­cess.
Additionally, all points where water processed by this system is accessible outside the system must be equipped with child-proof valves.
1.3 State Regulations The State of Colorado has strict requirements governing the diversion and use of
rainwater. Please check local and state requirements to see if special approval must be obtained before the installation of this or any other rainwater harvesting equipment.
1. Preliminary Considerations
4 of 13
* Htot = total height
Tank
700 US-gallons
2700 litres
1000 US-gallons
3750 litres
1250 US-gallons
4800 litres
1700 US-gallons
6500 litres
Art. No.
81011001
81011002
81011003
81010059
Weight
321.5lbs/120 kg
401.8lbs/150 kg
495.6lbs/185 kg
589.4lbs/220 kg
L
81.9“/2080 mm
89.8“/2280 mm
89.8“/2280 mm
94“/2390 mm
W
61.6“/1565 mm
69“/1755 mm
78.1“/1985 mm
86“/2190 mm
H
55.1“/1400 mm
62.6“/1590 mm
71.7“/1820 mm
82.7“/2100 mm
Htot*
79.1“/2010 mm
86.6“/2200 mm
95.7“/2430 mm
106.7“/2710 mm
2. Technical data
47.2
Loading...
+ 8 hidden pages