Graco ULTRA MAX II - MARK V, ULTRA MARK X Quick Operator's Manual

www.graco.be
ULTRA®MAX II - MARK V
Premium & Platinum MARK X
Connect hose to sprayer and gun. Tighten hose connections with wrench. Unscrew tip & guard from gun.
Fill throat packing nut with TSL
to prevent premature packing wear.
Make sure power switch is set to OFF.
Plug electrical cord into grounded outlet.
Turn prime valve to Prime position (down).
Place siphon tube in pail partially filled with water.
Turn pressure control knob to lowest pressure (platinum range only), and set power switch to ON.
Increase pressure until sprayer starts and water runs out of prime tube. Let water run out of prime tube for 15 seconds.
Decrease pressure until sprayer stops. Make sure you are not in E-Control* mode. (*platinum range only).
Turn prime valve to Spray position (horizontal).
Make sure safety lever of gun is OFF.
Aim gun at inside wall of water pail and squeeze trigger.
Increase pressure until sprayer starts. Keep gun triggered into water pail for 1 minute. Release trigger.
Turn prime valve to Prime position (down).
Place siphon tube in paint pail, but leave drain tube in water pail.
Aim gun at inside wall of water pail, and squeeze trigger.
Transfer drain tube to paint pail.
Increase pressure until sprayer starts and paint comes out of drain tube.
Keeping gun triggered into water pail, turn prime valve to Spray position (horizontal).
When paint comes out of gun, release trigger and turn safety lever of gun to ON.
Screw tip & guard onto gun, making sure arrow-shaped handle of tip is pointing forward. You can reverse this tip to quickly clear clogs without taking it apart.
WATCHDOG™ (Ultra®Max II range only)
This procedure is for water-base paints and flushing fluids. For solvent-base paints and flushing fluids (i.e. mineral spirits), you must read Fire and Explosion Hazard in the Operating Instructions.
* check the Graco operations manual delivered with the unit for more details.
OPTIONS
WARNING
Quick Operator’s Guide
Empty displays/flashes and pump stops when WatchDog protection system detects an empty material pail.
Turn WatchDog switch OFF. Add material or reprime sprayer. Turn pump switch OFF and ON to reset WatchDog protection system.
Turn WatchDog switch ON and WatchDog ON displays.
Set pressure high enough to spray. The E-Control acts in place of the pressure control knob when the sprayer is in E-Control mode.
Press the E-Control UP or DOWN to increase or decrease the stall pressure setting by 3 bar.
If the stall pressure reaches the limit in either direction the sprayer beeps 3 times.
If the E-Control UP or DOWN is pressed and held, the stall pressure will change to maximum sprayer setting or 0 bar.
E-Control
(platinum range only)
SPRAYING
Turn safety lever of gun to OFF.
Point gun at area to be sprayed about 30 cm from surface, and begin moving gun before triggering. A good spray pattern is evenly distributed as it hits surface. Set pressure just high enough to spray without heavy edges. Use smaller tip size for thinner material and a larger tip size for thicker material if pressure adjustment cannot achieve even spray pattern.
SHUTDOWN AND CLEANUP * for AutoClean
2
: see bottom of this page
Set power switch to OFF.
Trigger gun until pressure is relieved.
Turn prime valve to Prime position (down).
Remove gun filter assembly.
Unscrew tip & guard from gun. Clean gun filter, inlet screen, tip, guard and manifold filter with water and brush.
Set power switch to ON, and increase pressure until sprayer starts.
As soon as Pump Armor comes out of drain tube, set power switch to OFF.
Screw inlet screen onto siphon tube, replace manifold filter and spacer, and assemble gun with filter, tip and guard.
Wipe outside of sprayer, hose and gun with rag soaked in water or mineral spirits.
Fill throat packing nut with TSL
Place drain tube and siphon tube in pail of water.
Turn pressure control knob to lowest setting, set power switch to ON, and increase pressure until sprayer starts. Let sprayer run and flush itself for 2 minutes.
Keeping gun triggered into water pail, turn prime valve to Spray position (horizontal).
Set power switch to OFF,
turn pressure control knob to lowest setting, and turn prime valve to Prime position (down).
Place drain tube in waste pail and siphon tube in container of Pump Armor
Assemble gun without filter.
Unscrew inlet screen from siphon tube.
WAST E
Keep gun triggered into pail for 1 minute, until water coming out of gun is clean.
Remove manifold filter and spacer.
GRACO N.V. Industrieterrein Oude Bunders Slakweidestraat 31 • B-3630 Maasmechelen Tel: +32 (89) 770 700 • Fax: +32 (89) 770 777 E-mail: info@graco.be • http://www.graco.be
All information, illustrations, and specifications in this document are based on the latest product information
available at the time of publication. The right is reserved to make changes at any time without notice.
Place suction tube in appropriate cleaning fluid.
To save paint from hose and pump, trigger gun into paint pail and increase pressure. When cleaning fluid appears, release gun trigger.
Turn pressure all the way down. Open drain valve.
Screw connector onto gun.
Rotate trigger lock clip 90° to lock trigger open.
Turn valve to AutoClean™position to start cleaning process.
Close drain valve.
Install tip and guard and briefly trigger gun into waiste pail to clean tip. Reverse tip if necessary.
Place gun in AutoClean connector.
Slide open end over back of handle.
AUTOCLEAN
2
GUIDE + HEAVY DUTY PRIME VALVE
When finished, remove trigger clip from gun handle.
Turn valve to prime position and then back to AutoClean to repeat cycle.
Unscrew connector from gun. Remove gun from connector.
© 2002, 2006, 2009 Graco N.V. · Form No. 328006 E (rev.D)· 05/09 · Printed in Europe.
Graco is certified ISO 9001.
Remove suction and drain tubes from paint. Place drain tube into waste pail and wipe suction tube clean.
Close drain valve. Switch power ON.
With clean fluid, briefly trigger gun into waste pail several times to clear any debris from front of gun.