INSTRUCTIONS–P
This manual contains important
warnings and information.
READ AND RETAIN FOR REFERENCE
Electric, 120 Vac
ARTS LIST
308–571
Rev
A
Ultra
3000 psi (210 bar) Maximum Working Pressure
Model
600 Pressure Control Kit
237–659, Series A
INTRODUCTION
Note
to owners of Ultra 600, Models 231–307 and
231–325, and Ultimate 600, Model 820–183, airless
paint sprayers:
The 237–659 pressure control kit replaces the
236–815 pressure control kit used on Ultra 600 and
Ultimate 600 airless paint sprayers.
This kit of
creases the maximum working pressure from 2750 psi
(195 bar) to 3000 psi (210 bar).
fers superior pressure regulation and in
-
WARNING
PRESSURIZED EQUIPMENT HAZARD
If you supply your own hoses and spray
gun, be sure the hoses are electrically
conductive, that the gun has a tip guard
and that each part is rated for at least 3000 psi
(210 bar) W
risk of serious injury caused by static sparking, fluid
injection or over-pressurization and rupture of the
hose or gun.
orking Pressure. This is to reduce the
V
erify that all hoses, guns, fittings, and accessories
used on your sprayer are rated for the new 3000
psi working pressure.
NOTE:
231–307 are 3000 psi (210 bar) rated.
Change your sprayer instruction manual to refer
ence the new 3000 psi (210 bar) working pressure:
Ultra 600 Manual 308–319: Cover
Ultimate 600 Manual 820–182: Cover
The spray gun and hose furnished in Model
, 4, 6, 8, 9.
and 39;
, 3, 5, 7, 8.
and 38.
INSTALLATION
Follow the
fer to the Repair section of the applicable manual ref
erenced above.
Pressure Relief Procedure
on page 2. Re
-
-
-
GRACO INC. P.O. BOX 1441
COPYRIGHT
MINNEAPOLIS, MN
1995, GRACO INC.
55440–1441

WARNING
WARNING
INJECTION HAZARD
Spray
from leaks or ruptured components can inject fluid into your body and cause extremely seri
ous injury
cause serious injury
T
, including the need for amputation. Fluid splashed in the eyes or on the skin can also
.
Fluid injected into the skin may look like just a cut, but it is a serious injury
cal attention.
Do not stop or deflect leaks with your hand, body
Follow the
ment.
ighten all fluid connections before operating the equipment.
Check the hoses, tubes, and couplings daily
not repair high pressure couplings; you must replace the entire hose.
Fluid hoses must have spring guards on both ends, to help protect them from rupture caused by
kinks or bends near the couplings.
Pressure Relief Procedure
below before cleaning, checking or servicing the equip
, glove or rag.
. Replace worn or damaged parts immediately
. Get
immediate medi
-
-
-
. Do
Pressure Relief Procedure
1. Engage
2. Turn sprayer OFF.
3.
Unplug sprayer
4.
Disengage spray gun safety latch
spray gun safety latch
.
Graco
TO
PLACE AN ORDER
utor
, or call this number to identify the distributor
closest to you:
1–800–367–4023 T
, contact your Graco distrib
oll Free
5. T
rigger spray gun into waste container to relieve
pressure.
Open drain valve.
6.
7.
Leave drain valve open until ready to spray again.
Phone Numbers
-
FOR TECHNICAL ASSIST
information or assistance regarding the application of
Graco equipment:
1–800–543–0339 T
ANCE,
service repair
oll Free
Sales
Foreign Offices:
Offices:
Atlanta, Chicago, Dallas, Detroit, Los Angeles, Mt. Arlington (N.J.)
Canada; England; Korea; Switzerland; France; Germany; Hong Kong; Japan
GRACO INC. P.O. BOX 1441
PRINTED
MINNEAPOLIS, MN
IN U.S.A.
308–571 1/95