Graco Ratio President Pump User Manual

Instructions – Parts List
Parts
2” BUNG MOUNT, 200 LITER (55 GALLON) DRUM SIZE
10:1 Ratio Presidentr Pump
Part No. 239326, Series A
62 bar (6.2 MPa, 900 psi) Maximum Fluid Working Pressure
6.2 bar (0.62 MPa, 90 psi) Maximum Air Input Pressure
Read warnings and instructions.
Refer to page 2 for the Table of Contents.
GRACO INC.ąP.O. BOX 1441ąMINNEAPOLIS, MNą55440-1441
Copyright 1998, Graco Inc. is registered to I.S. EN ISO 9001
0359
II 1/2 G T2
ITS03ATEX11228
Table of Contents
Symbols
Warnings 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operation 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Service 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Parts 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Warranty 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Graco Information 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WARNING
EQUIPMENT MISUSE HAZARD
Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury.
INSTRUCTIONS
D This equipment is for professional use only.
D Read all instruction manuals, tags, and labels before operating the equipment.
Warning Symbol
WARNING
This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions.
Caution Symbol
CAUTION
This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the corresponding instructions.
D Use the equipment only for its intended purpose. If you are uncertain about usage, call your Graco
distributor.
D Do not alter or modify this equipment. Use only genuine Graco parts and accessories.
D Check equipment daily. Repair or replace worn or damaged parts immediately.
D Do not exceed the maximum working pressure of the lowest rated system component. Refer to the
Technical Data on page 14 for the maximum working pressure of this equipment.
D Use fluids and solvents which are compatible with the equipment wetted parts. Refer to the Tech-
nical Data section of all equipment manuals. Read the fluid and solvent manufacturer’s warnings.
D Do not use hoses to pull equipment.
D Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not expose
Graco hoses to temperatures above 82_C (180_F) or below –40_C (–40_F).
D Wear hearing protection when operating this equipment.
D Do not lift pressurized equipment.
D Comply with all applicable local, state, and national fire, electrical, and safety regulations.
2 308738
WARNING
INJECTION HAZARD
Spray from the gun/valve, hose leaks, or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury.
D Fluid injected into the skin might look like just a cut, but it is a serious injury. Get immediate medi-
cal attention.
D Do not point the gun/valve at anyone or at any part of the body.
D Do not put your hand or fingers over the spray tip/nozzle.
D Do not stop or deflect leaks with your hand, body, glove or rag.
D Do not “blow back” fluid; this is not an air spray system.
D Always have the tip guard and the trigger guard on the gun when spraying.
D Check the gun diffuser operation weekly. Refer to the gun manual.
D Be sure the gun/valve trigger safety operates before spraying/dispensing.
D Lock the gun/valve trigger safety when you stop spraying/dispensing.
D Follow the Pressure Relief Procedure on page 8 whenever you: are instructed to relieve pres-
sure; stop spraying/dispensing; clean, check, or service the equipment; and install or clean the spray tip/nozzle.
D Tighten all fluid connections before operating the equipment.
D Check the hoses, tubes, and couplings daily. Replace worn, damaged, or loose parts immediately.
Permanently coupled hoses cannot be repaired; replace the entire hose.
D Use only Graco approved hoses. Do not remove any spring guard that is used to help protect the
hose from rupture caused by kinks or bends near the couplings.
MOVING PARTS HAZARD
Moving parts, such as the air motor piston, can pinch or amputate your fingers.
D Keep clear of all moving parts when starting or operating the pump.
D Before servicing the equipment, follow the Pressure Relief Procedure on page 8 to prevent the
equipment from starting unexpectedly.
308738 3
WARNING
FIRE AND EXPLOSION HAZARD
Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury.
D Ground the equipment and the object being sprayed. Refer to Grounding on page 5.
D If there is any static sparking or you feel an electric shock while using this equipment, stop spray-
ing/dispensing immediately. Do not use the equipment until you identify and correct the problem.
D Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid
being sprayed/dispensed.
D Keep the spray/dispense area free of debris, including solvent, rags, and gasoline.
D Electrically disconnect all equipment in the spray/dispense area.
D Extinguish all open flames or pilot lights in the spray/dispense area.
D Do not smoke in the spray/dispense area.
D Do not turn on or off any light switch in the spray/dispense area while operating or if fumes are
present.
D Do not operate a gasoline engine in the spray/dispense area.
TOXIC FLUID HAZARD
Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed.
D Know the specific hazards of the fluid you are using.
D Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local,
state and national guidelines.
D Always wear protective eyewear, gloves, clothing and respirator as recommended by the fluid and
solvent manufacturer.
4 308738
Installation
NOTES:
D Reference numbers and letters in parentheses in
the text refer to the callouts in the figures and drawings.
D Always use Genuine Graco Parts and Accessories,
available from your Graco distributor. If you supply your own accessories, be sure they are adequately sized and pressure-rated to meet the system’s requirements.
D Fig. 2 is only a guide for selecting and installing
system components and accessories. Contact your Graco distributor for assistance in designing a system to suit your particular needs.
Prepare the Operator
All persons who operate the equipment must be trained in the safe, efficient operation of all system components as well as the proper handling of all fluids. All operators must thoroughly read all instruction manuals, tags, and labels before operating the equipment.
Prepare the Site
Ensure that you have an adequate compressed air supply. Refer to the performance chart on page 15 to find the air consumption of your pump.
Keep the site clear of any obstacles or debris that could interfere with the operator’s movement.
D Pump: Use a ground wire and clamp. See Fig.1.
Loosen the grounding lug locknut (W) and washer (X). Insert one end of a 12 ga (1.5 mm@) minimum ground wire (Y) into the slot in lug (Z) and tighten the locknut securely. Connect the other end of the wire to a true earth ground. For a ground wire and clamp, order Part No. 237569.
Z
Y
X
W
0720
Fig. 1
D Air and fluid hoses: Use only electrically conductive
hoses with 150 m (500 ft) maximum combined hose length to ensure grounding continuity.
D Air compressor: Follow manufacturer’s
recommendations.
D Spray gun or dispensing valve: Connect to a
properly grounded fluid hose and pump.
D Object being sprayed: Follow your local code.
Have a grounded, metal pail available for use when flushing the system.
Mounting the Pump
Screw the bung adapter (B) tightly into the drum bung hole and tighten the thumbscrew to hold the pump about 13 mm (0.5 in.) off the bottom of the drum. Loosen the drum vent plug to prevent forming a vacuum. The pump dimensions are shown on page 13.
Grounding
WARNING
FIRE AND EXPLOSION HAZARD
Before operating the pump, ground the system as explained below. Also read the section FIRE AND EXPLOSION HAZARD on page 4.
D Fluid supply container: Follow your local code.
D Solvent pails used when flushing: Follow your local
code. Use only metal pails, which are conductive, placed on a grounded surface. Do not place the pail on a nonconductive surface, such as paper or cardboard, which interrupts the grounding continuity.
D To maintain proper grounding continuity when
flushing or relieving pressure, always hold the metal
part of the spray gun/dispense valve firmly to the side of a grounded metal pail, then trigger the gun/valve.