Graco Fast-Ball 222103, Fast-Ball 685438, Fast-Ball 222104, Fast-Ball 222051 Instructions Manual

Instructions
Model 222051
Models 222103 and 222104
1:1 Ratio
Fast-Ball
For dispensing non-abrasive oils and lubricants only.
Universal Pump
55 Gallon Drum, Bung-Mount Pump
275 Gallon Tank, Bung-Mount Pump
Universal Pump, PTFE Cup
180 psi (1.2MPa, 12.4 bar) Maximum Air and Fluid Working Pressure
Pumps
307906ZAA
EN
Important Safety Instructions
Read all warnings and instructions in this manual. Save these instructions.
Warnings
WARNING
Warnings
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.
FIRE AND EXPLOSION HAZARD
When flammable fluids are present in the work area, such as gasoline and windshield wiper fluid, be aware that flammable fumes can ignite or explode. To help prevent fire and explosion:
Use equipment only in well-ventilated area.
Eliminate all ignition sources, such as cigarettes and portable electric lamps.
Ground all equipment in the work area.
Keep work area free of debris, including rags and spilled or open containers of solvent and gasoline.
Do not plug or unplug power cords or turn lights on or off when flammable fumes are present.
Use only grounded hoses.
Stop operation immediately if static sparking occurs or you feel a shock. Do not use equipment until you identify and correct the problem.
Keep a working fire extinguisher in the work area.
SKIN INJECTION HAZARD
High-pressure fluid from dispensing device, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical
treatment.
Do not point dispensing device at anyone or at any part of the body.
Do not put your hand over the fluid outlet.
Do not stop or deflect leaks with your hand, body, glove, or rag.
Follow the Pressure Relief Procedure when you stop dispensing and before cleaning, checking, or servicing equipment.
Tighten all fluid connections before operating the equipment.
Check hoses and couplings daily. Replace worn or damaged parts immediately.
2 307906ZAA
Warnings
WARNING
EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury.
Do not operate the unit when fatigued or under the influence of drugs or alcohol.
Do not exceed the maximum working pressure or temperature rating of the lowest rated system com­ponent. See Technical Specifications in all equipment manuals.
Use fluids and solvents that are compatible with equipment wetted parts. See Technical Specifica- tions in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete infor­mation about your material, request Safety Data Sheets (SDSs) from distributor or retailer.
Turn off all equipment and follow the Pressure Relief Procedure when equipment is not in use.
Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufac­turer’s replacement parts only.
Do not alter or modify equipment. Alterations or modifications may void agency approvals and create safety hazards.
Make sure all equipment is rated and approved for the environment in which you are using it.
Use equipment only for its intended purpose. Call your distributor for information.
Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
Do not kink or over bend hoses or use hoses to pull equipment.
Keep children and animals away from work area.
Comply with all applicable safety regulations.
MOVING PARTS HAZARD
Moving parts can pinch, cut or amputate fingers and other body parts.
Keep clear of moving parts.
Do not operate equipment with protective guards or covers removed.
Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, follow the Pressure Relief Procedure and disconnect all power sources.
TOXIC FLUID OR FUMES HAZARD
Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed.
Read Safety Data Sheets (SDSs) to know the specific hazards of the fluids you are using.
Route exhaust away from work area. If diaphragm ruptures, fluid may be exhausted into the air.
Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.
PERSONAL PROTECTIVE EQUIPMENT
Wear appropriate protective equipment when in the work area to help prevent serious injury, including eye injury, hearing loss, inhalation of toxic fumes, and burns. Protective equipment includes but is not limited to:
Protective eyewear, and hearing protection.
Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer.
307906ZAA 3
Installation
Installation
Typical Installation
Install the accessories in order shown in the typical installation in FIG. 1. The installation shown in FIG. 1 is only a guide for selecting and installing a pump; it is not an actual system design. Contact your Graco distributor for assis­tance in designing a system to suit your needs.
NOTE: Blow out all lines with compressed air before you connect the pumps.
NOTICE
Always mount the pump firmly to a wall bracket or a bung on a drum. Never operate pump while it is not mounted. Such use could damage the pump and fit­tings.
NOTICE
Do not hang the air accessories directly on the air inlet (P). The fittings are not strong enough to support the accessories and may break. Provide a bracket on which to mount the accessories.
FIG. 1
KEY
A Air shutoff valve BAir filter C Air regulator and gauge D Air motor lubricator E Bleed-type master air valve (required, Part No. 110223) F Air and fluid hose kits G Ground wire (required Part No. 222011) H Fluid shutoff valve J Wall bracket
4 307906ZAA
K Universal pump (Model 222051) L Suction kit M 55 gallon drum bung-mount pump (Model 222103) N Fluid drain valve (required Part No. 210658) P Air inlet Q Ball valve (fore releasing collected moisture) R Thermal relief kit (required for permanent installations,
Part No. 237601)
28 Bung adapter
Installation
Grounding
Proper grounding is an essential part of maintaining a safe system.
The equipment must be grounded to reduce the risk of static sparking and electric shock. Electric or static sparking can cause fumes to ignite or explode. Improper grounding can cause electric shock. Grounding provides an escape wire for the electric current.
Pump: use ground wire and clamp (supplied) as shown in F
IG. 2.
Air compressor: follow manufacturer’s recommendations.
Object being dispensed to: follow local code.
Fluid supply container: follow local code.
To maintain grounding continuity when flushing or relieving pressure: hold metal part of thedispense
valve firmly to the side of a grounded metal container, then trigger the valve.
To ground the pump, remove the ground screw (Z) and insert through eye of the ring terminal at the end of the ground wire (Y). Fasten the ground screw back onto the pump and tighten securely. Connect the other end of the wire to a true earth ground. To order a ground wire and clamp, order Part No. 222011.
System Accessories
Refer to FIG. 1, page 4.
Required Accessories
Three accessories are required in your system to help reduce the risk of serious bodily injury, including fluid injection, splashing of fluid in eyes or on skin, injury from moving parts when you are adjusting or repairing the pump, and explosion from static sparking.
Bleed-type master air valve (E): required in your system to relieve air trapped between it and the air motor after the air supply is shut off. Trapped air can cause the air motor to cycle unexpectedly, causing serious injury if you are adjusting or repairing the pump. As an alternative, use a quick-disconnect couple fitting. Install them near the pump air inlet within easy reach from the pump.
Fluid drain valve (N): assists in relieving fluid pressure in the displacement pump, hoses and dispensing valve. Triggering the valve to relieve pressure may not be sufficient.
Grounding wire (G): reduces the risk of static sparking.
Additionally, for permanent installations, a thermal relief kit is required.
Thermal Relief Kit (R): assists in relieving pressure in the pump, hose and dispensing valve due to heat expansion.
FIG. 2
307906ZAA 5
Other Accessories
Extension Tubes: Pump models 222103 and 222104 have extension tubes. An extension tube may be added to the Universal pump for use in sub­merged applications. To install, apply PTFE tape to the female threads at the top of the tube. Thread the tube tightly into the intake housing of the Universal pump. Also install a bung adapter. To order a stan­dard 2-inch bung adapter, order Part No. 222308.
Installation
Air and Fluid Hose Kits (F): An 18-inch kit for wall mounted pumps and a 6-foot kit for drum-mounted pumps are available. Use a minimum 1/4-inch ID air supply hose between the pump air inlet and the air accessories. To order a kit with a 1/4-inch air hose, 1/4-inch swivel elbow, 3/4-inch fluid hose, and 3/4-inch swivel elbow, order one of the following kits:
- 222118 - 18-inch (0.4 m) hose kit for wall
mounted pump.
- 222119 - 6-foot (1.8 m) hose kit for drum
mounted pump.
Wall Bracket (J): The wall bracket is used for mounting the Universal pump. The wall bracket is sized to fit any Graco pump designed to use a 2-inch bung adapter. Order Part No. 203987.
Runaway Valve: Install a pump runaway valve to shut off the air to the pump when the pump acceler­ates beyond the pre-adjusted setting. A pump that is in a runaway condition can be seriously damaged.
NOTICE
Never allow the pump to run dry of the fluid being pumped. A dry pump quickly accelerates to a high speed, possibly damaging itself, and it may get very hot.
Air Filter (B): The air filter removes harmful dirt and moisture from the compressed air supply. A 300 psi (2.1 MPa, 21 bar), 1/4-inch npt(f) air filter (20 micron) is available from Graco. Order Part No.
110146.
Air and Fluid Shutoff Valves (A and H): Install air shutoff valve (A) and fluid shutoff valve (H) as shown in F
IG. 1, page 4, to isolate the pump while
you are servicing it.
Quick-Disconnect Coupler and Nipple: The quick-disconnect coupler and nipple (not shown) are used to quickly disconnect the air supply. Attach the coupler (Part No. 208536) to the pump air inlet hose, and install the nipple (Part No. 169970) to the pump air inlet (P).
Thermal Relief Kit: Install the thermal relief kit on the dispensing valve side of the pump to assist in relieving pressure in the pump, hose and dispensing valve due to heat expansion. A 600 psi (4.2 MPa, 41 bar) thermal relief kit is available from Graco. Order Part No. 237601.
Bleed-Type Master Air Valve (E): Install a bleed-type master air valve to relieve air trapped between it and the motor when the valve is closed. A 300 psi (2.1 Mpa, 21 bar), 1/4-inch npt(f) bleed type master air valve is available from Graco. Order Part No. 110223.
Suction Kit (L): The suction kit is for use with the wall-mounted Universal pump. It includes a drum tube and hose. Order Part No. 213099.
Air Motor Lubricator (D): The air motor lubricator provides automatic air motor lubrication. A 250 psi (1.7 MPa, 17.4 bar), 1/4-inch npt(f) air motor lubrica­tor is available from Graco. Order Part No. 110148.
Air Regulator and Gauge (C): The air regulator and gauge are used to control air pressure and pump speed. A 0-200 psi (0-1.4 MPa, 0-14 bar) reg­ulated pressure range 300 psi (2.1 MPa, 21 bar) maximum, 1/4-inch npt(f) air regulator and gauge are available from Graco. Order Part No. 110147.
6 307906ZAA