Graco C04074, C04090, C04068, C04087, C04076 User Manual

Instructions-Parts
950SeriesSealantGun
For dispensing sealant from caulking tubes. For professional use only.
Important Safety Instructions
Read all warnings and instructions in this manual. Save these instructions. More warnings.
Models Palm Grip Gun:
2.5 oz. (C04074) and 6 oz (C04087)
Pistol Grip Gun:
2.5 oz. (C04076), 6 oz. (C04090), and 12 oz. (C04068)
309968D
ENG
PROVEN QUALITY. LEADING TECHNOLOGY.
Contents
Warnings ........................................................... 3
......................................................................... 3
Installation.......................................................... 4
Manual Applications..................................... 4
Automatic Appliations................................... 4
Air Requirements......................................... 4
Operation........................................................... 4
Air-Powered Sealant Guns ........................... 4
Manual Sealant Guns................................... 4
Gun Tip/Nozzle Safety........................... 4
Pressure Relief Procedure............................ 5
Troubleshooting.................................................. 6
Service .............................................................. 7
Sealant Gun Body Disassembly
(C04093)........................................ 7
Gun Handle Disassembly (C04079) .............. 7
Sealant Gun Reassembly (C04093) .............. 7
Gun Handle Assembly (C04079)................... 7
Parts.................................................................. 8
Technical Data ...................................................10
Accessories........................................................ 10
Notes ............................................................... 11
Graco Standard Warranty....................................12
2
309968D
Warnings
The following warnings are for the setup, use, grounding, maintenance and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risks. When these symbols appear in the body of this manual refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.
WARNING
PRESSURIZED EQUIPMENT HAZARD
Fluid from and cause s
• Follow the Pressure Relief Procedure when you stop spraying/dispensing and before cleaning, checking, or servicing equipment.
•Tightena
• Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately.
EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury.
• Do not operate the unit when fatigued or under the influence of drugs or alcohol.
• Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals.
• Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information about your material, request MSDS from distributor or retailer.
• Do not leave the work area while equipment is energized or under pressure. Turn off all equipment and follow the Pressure Relief Procedure when equipment is not in use.
• Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufacturer’s replacement parts only.
• Do not alter or modify equipment.
• Use equipment only for its intended purpose. Call your distributor for information.
• Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
• Do not kink or over bend hoses or use hoses to pull equipment.
• Keep children and animals away from work area.
• Comply with all applicable safety regulations.
the equipment, leaks, or ruptured components can splash in the eyes or on skin
erious injury.
ll fluid connections before operating the equipment.
SONAL PROTECTIVE EQUIPMENT
PER
must wear appropriate protective equipment when operating, servicing, orwheninthe
You
rating area of the equipment to help protect you from serious injury, including eye injury,
ope
aring loss, inhalation of toxic fumes, and burns. This equipment includes but is not limited to:
he
• Protective eyewear, and hearing protection.
spirators, protective clothing, and gloves as recommended by the fluid and solvent
•Re
nufacturer.
ma
309968D 3
Installation
Operation
Topics Covered in this Chapter
Manual ApplicationsAutomatic AppliationsAir Requirements
Note
Read this manual thoroughly before installing sealant gun.
Inspect sealant gun for shipping damage. If damaged, notify the carrier immediately.
Manual Applications
The palm and pistol grip sealant guns are used in hand-held applications.
1. Secure gun in a way that allows proper routing of air hose and fitting.
2. Make sure gun does not impede movement of person.
3. Tighten hose connections before operating equipment. The air-powered sealant gun can be supplied air from any standard air pump.
Topics Covered in this Chapter
Air-Powered Sealant GunsManual Sealant GunsPressure Relief Procedure
Air-Powered Sealant Guns
The 950 Series, air-powered sealant guns dispense adhesives or sealants from 2.5, 6 or 12 ounce polyethylene cartridges. Each size of these lightweight, all metal guns, is available in two styles: pistol grip and palm grip.
The guns feature an interchangeable gun body and actuator with a fast change cartridge knob included. The cartridge retainers are corrosion-resistant, will fit all handles and are made of high strength steel to prevent cartridge splitting under pressure.
In operation, the dispense rate is controlled through air pressure, trigger position and nozzle orifice. When the gun is actuated, air pressure forces the plunger down, inside the cartridge, forcing material out the nozzle. When the trigger is released, pressure is removed and dispensing stops.
4. Do not exceed maximum working pressure of sealant gun.
Automatic Appliations
The palm grip and pistol grip sealant guns are not designed for use in high production operations. Never mount or secure any hand-held gun to a fixture or robot arm.
Air Requirements
For information describing the air pressure requirements, refer to the technical data supplied with the sealant gun..
Manual Sealant Guns
The manually-operated sealant fun for 2.5, 6 and 12 ounce cartridges uses a smooth plunger rod for easy operation. Simply releasing the trigger, releases the pressure; dispensing is easy to control and stops quickly.
GunTip/NozzleSafety
Useextremecautionwhencleaningorchanging dispense sealant gun tips/nozzles. Always follow the Pressure Relief Procedure first, and then remove the spray tip/nozzle to clean it.
Never wipe off build-up around the tip/nozzle until pressure is relieved.