Graco Standard Warranty....................................12
2
309968D
Warnings
The following warnings are for the setup, use, grounding, maintenance and repair of this equipment. The
exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific
risks. When these symbols appear in the body of this manual refer back to these Warnings. Product-specific
hazard symbols and warnings not covered in this section may appear throughout the body of this manual
where applicable.
WARNING
PRESSURIZED EQUIPMENT HAZARD
Fluid from
and cause s
• Follow the Pressure Relief Procedure when you stop spraying/dispensing and before
cleaning, checking, or servicing equipment.
•Tightena
• Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately.
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
• Do not operate the unit when fatigued or under the influence of drugs or alcohol.
• Do not exceed the maximum working pressure or temperature rating of the lowest rated
system component. See Technical Data in all equipment manuals.
• Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data
in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete
information about your material, request MSDS from distributor or retailer.
• Do not leave the work area while equipment is energized or under pressure. Turn off all
equipment and follow the Pressure Relief Procedure when equipment is not in use.
• Check equipment daily. Repair or replace worn or damaged parts immediately with genuine
manufacturer’s replacement parts only.
• Do not alter or modify equipment.
• Use equipment only for its intended purpose. Call your distributor for information.
• Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
• Do not kink or over bend hoses or use hoses to pull equipment.
• Keep children and animals away from work area.
• Comply with all applicable safety regulations.
the equipment, leaks, or ruptured components can splash in the eyes or on skin
erious injury.
ll fluid connections before operating the equipment.
SONAL PROTECTIVE EQUIPMENT
PER
must wear appropriate protective equipment when operating, servicing, orwheninthe
You
rating area of the equipment to help protect you from serious injury, including eye injury,
ope
aring loss, inhalation of toxic fumes, and burns. This equipment includes but is not limited to:
he
• Protective eyewear, and hearing protection.
spirators, protective clothing, and gloves as recommended by the fluid and solvent
•Re
nufacturer.
ma
309968D3
Installation
Operation
Topics Covered in this Chapter
♦ Manual Applications
♦ Automatic Appliations
♦ Air Requirements
Note
Read this manual thoroughly before installing
sealant gun.
Inspect sealant gun for shipping damage. If
damaged, notify the carrier immediately.
Manual Applications
The palm and pistol grip sealant guns are used in
hand-held applications.
1. Secure gun in a way that allows proper routing
of air hose and fitting.
2. Make sure gun does not impede movement of
person.
3. Tighten hose connections before operating
equipment. The air-powered sealant gun can be
supplied air from any standard air pump.
The 950 Series, air-powered sealant guns dispense
adhesives or sealants from 2.5, 6 or 12 ounce
polyethylene cartridges. Each size of these
lightweight, all metal guns, is available in two styles:
pistol grip and palm grip.
The guns feature an interchangeable gun body and
actuator with a fast change cartridge knob included.
The cartridge retainers are corrosion-resistant, will fit
all handles and are made of high strength steel to
prevent cartridge splitting under pressure.
In operation, the dispense rate is controlled through
air pressure, trigger position and nozzle orifice. When
the gun is actuated, air pressure forces the plunger
down, inside the cartridge, forcing material out the
nozzle. When the trigger is released, pressure is
removed and dispensing stops.
4. Do not exceed maximum working pressure of
sealant gun.
Automatic Appliations
The palm grip and pistol grip sealant guns are not
designed for use in high production operations.
Never mount or secure any hand-held gun to a fixture
or robot arm.
Air Requirements
For information describing the air pressure
requirements, refer to the technical data supplied
with the sealant gun..
Manual Sealant Guns
The manually-operated sealant fun for 2.5, 6 and 12
ounce cartridges uses a smooth plunger rod for easy
operation. Simply releasing the trigger, releases the
pressure; dispensing is easy to control and stops
quickly.
GunTip/NozzleSafety
Useextremecautionwhencleaningorchanging
dispense sealant gun tips/nozzles. Always follow the
Pressure Relief Procedure first, and then remove the
spray tip/nozzle to clean it.
Never wipe off build-up around the tip/nozzle until
pressure is relieved.
4
309968D
Loading...