Graco Airgard 224-040, Airgard Series A Instructions-parts List Manual

INSTRUCTIONS-PARTS
LIST.
308-201
This
manual
WARNINGS
READ
AND
AND
RETAIN
IMPORTANT
INSTRUCTIONS
FOR
AIRGARD"
Pump
120
psi
(8.4
bar)
kXlMUM
Model
224-040,
Series
REFERENCE
Runaway
AIR
INLET
PRESSURE
A
w
0-
Valve
Rev
A
TABLE
Warnings.. .................................
Installation Operation
Troubleshooting..
Service Parts Drawing and List
Dimensional Drawing Technical Data Warranty Back Cover Graco Toll-Free Phone Numbers Back Cover
...............................
..................................
....................................
..........................
OF
CONTENTS
...........................
.......................
...............
Back Cover
..................... Back Cover
.....
GRACO INC.
P.0.
BOX
0
COPYRIGHT
.2
2,3
.4
.5
.6
.7
1441 MINNEAPOLIS, MN 55440-1441
1992,
GRACO INC.
OBSERVE ALL WARNINGS. Read And Understand All Instruction Manuals Before Operating Equipment.
Use Only With Compressed Air
This valve is for useonfywithcompressedair. It is not designed for use with any other power source. NEVER use any other gas or fluid in the runaway valve.
General Safety
Any misuse of the runaway valve, such as overpressurizing,
modifyingparts,orusingwomordamagedparts,cancausethe valveto ruptureand result inseriousinjuryorpropertydamage.
NEVER alter or modify any part of the runaway valve; doing so could cause it to malfunction.
CHECK all equipment regularly and repair or replace worn or damaged parts immediately.
Moving Parts Hazard
To reduce the risk of serious injury, including pinching or am-
putationoffingersorhands, NEVERusetherunawayvalveasa pump shutoff vaNe. The valve does not completely shut off the airsupply,and thepumpwillcontinuetooperateslowlyafterthe valve closes. The air motor piston (located behind the air motor platesorshield) moveswhenairissuppliedtothemotor.NEVER operate the pump wlth the air motor plates or shield removed.
System Pressure
NEVER exceed 120 psi (8.4 bar) MAXIMUM AIR INLET PRES-
SURE to the vaive, or the maximum air inlet pressure stated on
your pump.
DONOTexceedthemaximumworkingpressureofanycompo­nent or accessory used in the system.
Pressure Relief Procedure
To reduce the risk of serious injury, includin injury from
Alwayswearprotectiveeyewear,gloves,clothingandrespirator as recommended by the fluid and solvent manufacturer.
Alwaysfollowthe Pressure Relief Procedureinyourseparate pump manual, before checking, clearing, cleaning, flushing or servicing any part of the system.
moving parts, alwaysfollowthisprocedurew
are servicing the runaway valve.
1. Follow the Pressure Relief Procedure in your sepa­rate pump manual.
2. Shut off the main air shutoff valve.
3,
eneveryou
IMPORTANT
United States Government safety standards have been adopted under the Occupational Safety and Health Act. These standards -
particularly the General Standards, Pati1910, and the Construction Standards, Part 1926 - should be consulted.
INSTALLATION
Reference letters and numbers in the text refer to Figs 1 and 2 and the Parts Drawing on page 7.
Install an air filter (A) to remove harmful dirt and moisture
from the compressed air supply. Install a main air shutoff valve (6) to isolate the runaway valve for servicing. If you supply your own accessories, be sure they are ade­quately sized and pressure-rated to meet the system’s requirements.
The Typical Installations shown on page 3 are only ex­amples Contact your Grace representative or Grace Technical Assistance (see back page) for assistance in
designing a system to meet your particular needs.
install one runaway valve for each pump; the valve will control only one pump.
WARNING
A bleed-type master air valve (C) is required in
your system. The bleed-type master air valve re-
lieves air trapped between this valve and the pump after the air is shut off. Trapped air can cause the pump to cycle unexpectedly. Locate the valve close to the pump.
2 308-201
Installing the Runaway Valve on King’“, Bulldoge,
and Senatore Motors
Detail Aof Fig 1 shows the runaway valve (D) used with a
Bulldoge air motor, mounted on a cart. Mounting on a wall bracket is done the same way. Install the runaway valve between the air manifold (E) and the air regulator
(F), using necessary adapters. Use the 90” swivel adapter (G, supplied) to connect the runaway valve out­let to the air regulator inlet.
lnstalltng the Runaway Valve on Presidente Motors
Details B and C of Fig 1 show the runaway valve (D) used with a Presidente air motor, mounted on a wall and on a cart. Install the runaway valve between the air regu-
lator (F) and the bleed-type master air valve (C), using necessary adapters. Use the 90” swivel adapter (G, supplied) to connect the runaway valve outlet to the
bleed valve inlet.
Signal Port (See Fig 2)
When the runaway valve trips, the signal port (S) is pres-
surized. This air pressure will operate a pilot-operated valve to turn on a remote device such as a signal lamp or alarm. The pressure at this port will be 15% less than the
inbound air pressure. The volume ofairpassing through
the port will be low.
When no remote sensor is being used, this port is
plugged with a screw (3).
TYPICAL INSTALLATIONS
KEY
A Air Line Filter
B
C
D
E
F
Q
RECOMMENDED ADAPTERS
Main Air Shutoff Valve Bleed-Type Master
(required, for pump)
Pump Runaway Valve Air Manifold Air Regulator Runaway Valve Swivel (supplied)
Air
Valve
DETAIL
175-013
157-191 Reducer: 314 npt 160427 Swivel Adapter;
B
(WALL-MOUNTED DETAIL C (CART-MOUNTED
MAIN AIR
B
LIN
PRESIDENT AIR MOTOR)
Nipple: 314 npt
314 npt(m)
x
112
x
314 npsm(f)
npt
/
Fig 1
c
308-201
01267
3