Kit Instructions/Parts
Throat Seal 
406878D
Upgrade Kits
To upgrade older 2000cc, 3000cc, and 4000cc High-Flo Plus Lowers that have 
torqueable throat packings and an open wet-cup to spring loaded throat 
packings and an open wet-cup. 
See List of Kit Part Numbers below.
EN
Important Safety Instructions
Read all warnings and instructions in this manual and in 
your 4-Ball pump manual 3A0540. Save all instructions.
NOTE: Use these kits to upgrade the following lowers. A Shield 
Kit is also required; see manual 406876 to order the correct kit 
for your pump.
Kit Lower
24H352 (SST) 243734 (2000cc)
243771 (2000cc) 
248329 (2000cc) 
248332 (2000cc)
24F287 (SST) 243735 (3000cc)
243772 (3000cc) 
248330 (3000cc) 
248333 (3000cc) 
240591 (3000cc) 
240592 (3000cc)
24H356 (SST) 243736 (4000cc)
243773 (4000cc) 
248331 (4000cc)
248334 (4000cc) 
24H353 (CST) 243731 (2000cc) 
24F288 (CST) 243732 (3000cc) 
24H357 (CST) 243733 (4000cc)
NOTE: See page 2 for drawing of pump assembly showing kit 
parts and location.
Ref. Description Qty
2 HOUSING, outlet 
3 GASKET, cylinder 
5O-RING 
15 O-RING; ptfe 
17 SEAL, seat; UHMWPE 
19 ROD, piston 
22 O-RING; ptfe 
23 O-RING; ptfe 
25 PACKING, piston; UHMWPE 
27 CARTRIDGE, packing, throat 
28 SPRING 
30 V-PACKING; UHMWPE 
31 V-PACKING; leather 
32 GLAND, female 
33 GLAND, male 
34 WET-CUP 
39 SPACER 
40 COVER, wet-cup 
51 O-RING 
52 O-RING; ptfe
1 
2 
4 
2 
2 
1 
1 
1 
1 
1 
1 
6 
4 
1 
2 
1 
1 
1 
2 
2

2
5
40
4
17
15
1
1
22
3
23
1
1
2
25
1
39
51
34
1
5
1
3
1
52
33
1
30
1
33
1
31
32
31
1
1
1
3
1
1
6
19
28 
27
52
8
1
Apply lubricant to all packings.
2
Apply removable (blue) Loctite 
entire length of threads. Sealant must 
be allowed to cure for a minimum of 12 
hours before use.
3
Torque to 200-210 ft-lb (270-285 N•m).
All written and visual data contained in this document reflects the latest product information available at the time of publication. 
® 243 to 
Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 406878
4
Apply thread lubricant.
5
Torque to 18-20 ft-lb (24-27 N•m).
6
Tighten uniformly until cylinder is 
seated then torque to 60-65 ft-lb (81-88 
N•m).
8
Apply high strength (red) Loctite 
or 2760 to entire length of threads. 
Sealant must be allowed to cure for a 
minimum of 12 hours before use.
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea 
GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS, MN 55440-1441 • USA 
Copyright 2010, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
www.graco.com