Graco 406826A User Manual

GENUINE GRACO PARTS AND ACCESSORIES
Torque Instructions
Husky®1050 Diaphragm Pumps
Important Safety Instructions
Read all warnings and instructions in the Husky®1050 Air-Operated Diaphragm Pump
Repair/Parts manual. Save all instructions.
NOTE: Fluid cover and manifold fasteners have a thread-locking adhesive patch applied to the threads. If this patch is excessively worn, the screws may loosen during operation. Replace screws with new ones, or apply medium-strength (blue) Loctite or equivalent to the threads.
If fluid cover or manifold fasteners have been loosened, it is important to torque them using the following proce­dure to improve sealing.
NOTE: Always completely torque fluid covers before torquing manifolds.
Start all fluid cover screws a few turns. Then turn down each screw just until head contacts cover. Then turn each screw by 1/2 turn or less working in a crisscross pattern to specified torque. Repeat for manifolds.
406826A
1
4
3
2
ti13845a
5
2
3
4
1
67
8
Fluid cover and manifold fasteners:
100 in-lb (11.3 N•m)
Retorque the air valve fasteners (V) in a crisscross pat­tern to specified torque.
Air valve fasteners:
55 in-lb (6.2 N•m) for plastic center sections 80 in-lb (9.0 N•m) for metal center sections
Graco Inc. P.O. Box 1441 Minneapolis, MN 55440-1441
406826 Rev, A 08/2009 Copyright 2009, Graco Inc. is registered to ISO 9001
6
8
FIG. 1. Torque sequence
V
5
ti13846a
7
Loading...