Graco 406824C User Manual

GENUINE GRACO PARTS AND ACCESSORIES
Pulse Count Kits 24B796 and 24B798
Husky ® 1050 and Husky® 3300 Diaphragm Pumps
Kit 24B796
for pumps with a polypropylene or conductive polypropylene center section and air valve.
Kit 24B798
for pumps with an aluminum center section and air valve.
Important Safety Instructions
Read all warnings and instructions in the Air-Operated Diaphragm Pump Repair/Parts manual. Save all instructions.
Ref. Description Qty.
101
REED SWITCH ASSEMBLY 1
102
SCREW 1
LEFT RIGHT
Pin 1
(not used)
406824C
Pin 4
Pin 3
Pin 5
Common
Air valve
housing
T
H
G
I
R
T
F
E
L
101
102
Graco Inc. P.O. Box 1441 Minneapolis, MN 55440-1441
406824 Rev, C October 2012 Copyright 2009, Graco Inc. is registered to ISO 9001
ti14538a
4
5
1
3
2
Pin 2
(not used)
ti14539a
See Instructions on reverse.
Installation
Use these kits with customer-supplied fluid manage­ment or inventory tracking systems. Each kit includes a module with two reed switches and a mounting screw.
1. Attach the reed switch module to the air valve.
2. Attach an M12, 5-pin female connector (customer supplied) to the reed switch to interface with cus­tomer wiring. See illustration on front.
Specifications
Type......................................................... Normally open
Maximum power ......................................
Maximum voltage..................................... 170 VDC
Initial contact resistance (Maximum) ....... 0.2 Ohms
Contact Capacitance (Typical)................. 0.2 pF
10 W
When properly connected, the reed switches detect the position of the air valve. Each reed switch is momentary and closes only when near the air valve magnet. The right reed switch is closed when the air valve is in the right position, and the left reed switch is closed when the air valve is in the let position. When a reed switch is opened then closed, or closed then opened, one com­plete pump cycle has occurred.
When connecting, note that either reed switch can detect one complete pump cycle. Both can be used, however, to detect half-cycles for greater precision or for system redundancy.
2 406824C