Graco 406813C User Manual

GENUINE GRACO PARTS AND ACCESSORIES
Air Valve Seal Kits
Husky® 1050 Diaphragm Pumps
Kits 24B769 and 24C983
206 O-RINGS, end cap 2 208 U-CUPS, piston 2 209 SCREW
Kit 24B769: M3 (shorter - for metal pumps) and #4 (longer - for plastic pumps) Kit 24C983: M3
DataTrak Models
with Runaway
Protection
All other models
206
2
1
Ref. Description Qty.
219 O-RING, for Kit 24B769 (used for DataTrak
models with runaway protection)
108 GASKET, air valve (not shown) 1
--- GREASE, lithium-based (not shown) 1
209
1
406813C
EN
1
See reverse for assembly directions.
3
3
1
1
206
219
Apply lithium-based grease.
1
U-cup lips must face piston.
2
Apply lithium-based grease to
3
contact surface.
Graco Inc. P.O. Box 1441 Minneapolis, MN 55440-1441
406813 Revision C - December 2012 Copyright 2009, Graco Inc. is registered to ISO 9001.
housing
air inlet side
208
1
2
1
1 2
208
206
1
ti14026b
Assembly
NOTE: Apply lithium-based grease whenever instructed
to grease.
1. Use all parts in the repair kits, as applicable to your pump. Clean other parts and inspect for damage. Replace as needed.
2. Grease the detent cam (204) and install into housing.
3. Grease the u-cups (208) and install on the piston with lips facing toward the center of the piston.
4. Grease both ends of the piston (202) and install it in the housing, with the flat side toward the cup (213). Be careful not to tear u-cups (208) when sliding pis­ton into housing.
5. Standard or Pulse Count models (no runaway protection solenoid): Grease new o-rings (206)
and install on the end caps. Install the end caps into the housing.
DataTrak models (with runaway protection sole­noid): Invert the air valve, with the air inlet facing
away from you. Grease and install new o-ring (206) on right-side end cap. Grease and install new o-ring (206) and the solenoid release button and o-ring (219) on left-side end cap. Install the end caps into the housing.
7. Grease and install the detent assembly (203) into the piston. Install the o-ring (214) on the cup (213). Apply a light film of grease to the outside surface of the o-ring and the inside mating surface of the base (212). Install the cup (213) on the base (212). Install the spring (211) onto protrusion on the cup. Install the cup assembly. Align the small round magnet in the base with the air inlet.
8. Grease the cup side and install the valve plate (205). Align the small hole in the plate with the air inlet. Tighten the screws (209) to hold it in place.
6. Install a retaining ring on each end to hold end caps in place.
2 406813C
Loading...