Graco 344838EN-A User Manual

ACS Module
Advanced Control System for E-Flo® 4-Ball Piston Pumps
Graco’s ACS Module provides optimal control of paint circulating systems when used with E-Flo pumps and 3rd party variable frequency drives (VFD’s).
• Provides optimized run cam profile for reduced pressure fluctuations
• Integrated pressure control mode available for on-demand fluid supply
• Real-time monitoring and reporting of fluid pressure and flow rate
Typical Advanced Control System (ACS) Setup
Personal Computer
or PLC
Graco ACS
Module
Customer Variable
Frequency Drive (VFD)
Technical Specifications:
Inputs:
Input Voltage . . . . . . . . . . . . . . 20-30 VDC, 250 mA, reverse polarity protected
Analog Inputs . . . . . . . . . . . . . . 2 inputs for 4-20 mA current loop sensing. Inputs
protected from direct application of 24 VDC
Digital Inputs . . . . . . . . . . . . . . 4 inputs: TDC, Position Sensor, AutoSleep and Reset.
Digital inputs are 24V logic level NPN
Outputs:
Analog Outputs . . . . . . . . . . . . . 2 – 4-20 mA loop for VFD communication, adjustable
offset and span
Digital Outputs . . . . . . . . . . . . . 2 – 1A, 24 VDC, open contact, normally open relay
outputs, used for back pressure regulator control and Drive Enable
Communications: . . . . . . . . . . . . . . 1 Ethernet port and 1 RS485 port
Ambient Conditions:
Operating temperature range . . 32-121ºF (0-50ºC)
Operating humidity . . . . . . . . . . 10-90% relative humidity, non-condensing
Installation Location: . . . . . . . . . . . . Non-Hazardous
Installation Type: . . . . . . . . . . . . . . . DIN rail
Instruction Manual . . . . . . . . . . . . . . 3A0006
Ordering Information:
24H372 ACS Module
16A630 TDC & Position Sensor Barrier
16A633 Pressure Transducer Barrier
When integrating an ACS Module the E-Flo pump must be configured with a Graco ATEX/FM sensor circuit.
Dimensions:
Module A B C Weight
ACS
2.3 in
(59 mm)
4.5 in
(114 mm)
E-Flo 4-Ball
Piston Pump
5.1 in
(130 mm)
1.1 lb
(0.5 kg)
Optional Equipment:
15V331 Ethernet IP Gateway Assembly
15V963 DeviceNet Gateway Assembly
15V964 Profibus Gateway Assembly
The ACS Module is compatible with a Visual Basic software program for set up and control through a personal computer. A free download is available on www.graco.com/finishing.
Optional Gateway assemblies provide networking and PLC communication with common protocols.