Graco 320449EN-B User Manual

Surge Tanks
Dampens Pump Pulsation for Consistent Finish Quality
High Volume
238986
Medium Volume
220157
• Reduces pulsation for consistent material delivery and uniform spray pattern
• High quality design reduces maintenance and charge pressure refills
• In-line flow configuration is easy to flush, making color changes quick and easy
• Isolate the surge tank and perform on-line maintenance with tee configuration
• Multiple fluid connection options accommodate global system requirements
238987 238988
Medium Volume
Tee Configuration
233736
Ordering Information
238986 High Volume Stainless Steel Model
Inlet/outlet: 2 npt(f)
238987 High Volume Stainless Steel Model
Inlet/outlet: 2 in (50.8 mm) sanitary Tri-Clamp
238988 High Volume Stainless Steel Model
Inlet/outlet: 1.5 in (38.1 mm) sanitary Tri-Clamp
218509 High Volume Carbon Steel Model
Inlet/outlet: 2 npt(f)
220157 Medium Volume Stainless Steel Model
Inlet/outlet: 1 npt(f) x 1-1/4 npt(f)
233736 Tee Configured Stainless Steel Model
Inlet/outlet: 3/4 BSPP(f)
Accessories
218742 Floor Stand Kit
Floor stand supports surge tank models 238983, 238984, 238985, 218509 and 222157
222011 Grounding Clamp and Wire
12 gauge x 25 ft (7.6 m) wire
Inlet/Outlet Fittings and Connectors
Accessories for surge tank models 238986, 238987 and 238988 to convert to different thread configurations.
187150 1-1/2 npt(f) x 2 in (50.8 mm) sanitary
191771 2 npt(f) x 2 in (50.8 mm) sanitary
188286 1-1/2 in (38.1 mm) sanitary Tri-Clamp connection
x 2 in (50.8 mm) sanitary
187004 2 in (50.8 mm) sanitary Tri-Clamp connection
x 2 in (50.8 mm) sanitary
107078 O-ring (one required with each inlet/outlet fitting)
Adapter Fittings for Surge Tank Model 233736
15A984 3/4 bspt(m) x 3/4 npt(m), stainless steel. Use with surge tank
model 233736 to convert fluid thread from BSPP to npt.
15A983 1/4 bspt(m) x 1/4 npt(m), stainless steel. Use with surge tank
model 233736 to convert air inlet thread from BSPP to npt.
Technical Specifications
Surge Tank High Volume Medium Volume
Part Number 238986, 238987, 238988 218509 220157 233736
Material of construction SST CS SST SST
Flow configuration In-line In-line In-line Tee configuration
Maximum fluid pressure 300 psi (21 bar, 2.1 MPa) 600 psi (42 bar, 4.2 MPa) 600 psi (42 bar, 4.2 MPa) 360 psi (25 bar, 2.5 MPa)
Maximum fluid flow* 20 gpm (76 lpm) 20 gpm (76 lpm) 15 gpm (57 lpm) N/A**
Inlet/outlet thread size 2 npt(f) or 2 in (50.8 mm) or
1.5 in (38.1 mm) sanitary tri-clamp
Maximum gas charge pressure 300 psi (21 bar, 2.1 MPa) 600 psi (42 bar, 4.2 MPa) 600 psi (42 bar, 4.2 MPa) 115 psi (8 bar, 0.8 MPa)
Diaphragm repair kit 249141 218799 220844 198777
Instruction manual
*Maximum flow rates are recommended maximums for peak performance. Exceeding these values reduces the surge tank’s ability to dampen pulsation. **Maximum flow rate does not apply to tee configuration as it is not a flow through (in-line) design.
All written and visual data contained in this document are based on the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice.
307707 307707 307707 307707
2 npt(f) 1 npt(f) / 1-1/4 npt(f) 3/4 BSPP(f)
Call today for product information or to request a demonstration.
877.84GRACO (1-877-844-7226) or visit us at www.graco.com.
©2011 Graco Inc. Form No. 320449 Rev. B 10/11 Electronic only. All other brand names or marks are used for identification purposes and are trademarks of their respective owners.