Graco 312769D User Manual

Instructions - Parts
Feed Pump and Agitator Kits
Supplies viscous materials from drums or 20 gallon hoppers to XM™ and XP70 plural-component sprayers.
Important Safety Instructions
Read all warnings and instructions in this manual. Save these instructions.
See page 5 for model information, including maximum working pressure and approvals.
President® 10:1 Kit
256433
Monark® 5:1 Kit
256276
T2 2:1 Kit
256275
Agitator Kit
256274
312769D
EN
r_256433_312769_1A
r_256276_312769_1A
r_256275_312769_1A
r_256433_312769_1A

Related Manuals

Contents
Related Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Feed Kit Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Install Feed Pump . . . . . . . . . . . . . . . . . . . . . . . . 6
Install Agitator . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Connect Air Lines . . . . . . . . . . . . . . . . . . . . . . . . 8
Flush Before Using Equipment . . . . . . . . . . . . . . 9
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Troubleshooting/Repair . . . . . . . . . . . . . . . . . . . . . 9
Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Feed Pump Kits . . . . . . . . . . . . . . . . . . . . . . . . . 10
Drum Feed Kits . . . . . . . . . . . . . . . . . . . . . . . . . 11
Agitator Kit 256274 . . . . . . . . . . . . . . . . . . . . . . 12
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Graco Standard Warranty . . . . . . . . . . . . . . . . . . . 14
Graco Information . . . . . . . . . . . . . . . . . . . . . . . . 14
Related Manuals
Manual Description
312359 XM Operation 313289 XM Repair - Parts 313292 OEM XM Instructions 3A0420 XP70 Sprayer Operation 312747 Double Wall Hoppers, Instructions -
Parts
308175
311882 T2 2:1 Ratio Transfer Pump
307044
308738
Tw is to rk
Instructions-Parts
5:1 Ratio Monark Instructions-Parts
10:1 Ratio President
Helix Mixer Instructions-Parts
®
Pump
®
Pump
2 312769D

Warnings

Warnings
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama­tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable.
WARNING
WARNINGWARNINGWARNING
FIRE AND EXPLOSION HAZARD
Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:
Use equipment only in well ventilated area.
Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc).
Keep work area free of debris, including solvent, rags and gasoline.
Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes are present.
Ground all equipment in the work area. See Grounding instructions.
Use only grounded hoses.
Hold gun firmly to side of grounded pail when triggering into pail.
If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem.
Keep a working fire extinguisher in the work area.
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
Do not operate the unit when fatigued or under the influence of drugs or alcohol.
Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals.
Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information about your material, request MSDS forms from distributor or retailer.
Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manu­facturer’s replacement parts only.
Do not alter or modify equipment.
Use equipment only for its intended purpose. Call your distributor for information.
Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
Do not kink or over bend hoses or use hoses to pull equipment.
Keep children and animals away from work area.
Comply with all applicable safety regulations.
TOXIC FLUID OR FUMES HAZARD
Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed.
Read MSDS’s to know the specific hazards of the fluids you are using.
Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.
Always wear impervious gloves when spraying or cleaning equipment.
312769D 3
Warnings
WARNING
WARNINGWARNINGWARNING
MOVING PARTS HAZARD
Moving parts can pinch or amputate fingers and other body parts.
Keep clear of moving parts.
Do not operate equipment with protective guards or covers removed.
Pressurized equipment can start without warning. Before checking, moving, or servicing equipment,
follow the Pressure Relief Procedure in this manual. Disconnect power or air supply.
PERSONAL PROTECTIVE EQUIPMENT
You must wear appropriate protective equipment when operating, servicing, or when in the operating area of the equipment to help protect you from serious injury, including eye injury, inhalation of toxic fumes, burns, and hearing loss. This equipment includes but is not limited to:
Protective eyewear
Clothing and respirator as recommended by the fluid and solvent manufacturer
•Gloves
Hearing protection
4 312769D

Feed Kit Models

Feed Kit Models
All kits fit drums or 20 gallon hoppers. Most packages include all air and fluid fittings and hoses. Approvals are only for the pumps or agitator and not for the entire package.
Complete
Package
(fluid and air) Description
256274 Agitator Kit with air
connection
256275 T2 2:1 Ratio Transfer
Pump Kit
256276
Monark
®
5:1 Ratio
Pump Kit
256433*
President
®
10:1 Ratio
Pump
256232 55 Gallon (200 Liter)
Drum Feed Kit,
includes agitator kit
256274 and 2:1 pump
kit 246275
256255 55 Gallon (200 Liter)
Drum Feed Kit,
includes agitator
256274 and 5:1 pump
kit 246276
Maximum Air
Input Pressure
100 psi (0.7 MPa, 7 bar)
180 psi (1.2 MPa, 12 bar)
180 psi (1.2 MPa, 12 bar)
90 psi (0.62 MPa, 6.2 bar)
N/A N/A
N/A N/A
Maximum Fluid
Working
Pressure
N/A
405 psi (2.8 MPa, 28 bar)
900 psi (6.2 MPa, 62 bar)
900 psi (6.2 MPa, 62 bar)
Approvals
(only for pumps and agitator)
0359 II 1/2 G T3
ITS03ATEX11226
0359 II 1/2 G T2
ITS03ATEX11228
0359 II 1/2 G T2
ITS03ATEX11228
See pump and agitator
approvals above.
See pump and agitator
approvals above.
* Does not include air hose, air fittings, or strainer to connect to XM sprayer pump lower.
312769D 5