The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back
to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where
applicable.
WARNING
WARNINGWARNINGWARNING
FIRE AND EXPLOSION HAZARD
Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent
fire and explosion:
•Use equipment only in well ventilated area.
•Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop
cloths (potential static arc).
•Keep work area free of debris, including solvent, rags and gasoline.
•Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes
are present.
•Ground all equipment in the work area. See Grounding instructions.
•Use only grounded hoses.
•Hold gun firmly to side of grounded pail when triggering into pail.
•If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment
until you identify and correct the problem.
•Keep a working fire extinguisher in the work area.
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
•Do not operate the unit when fatigued or under the influence of drugs or alcohol.
•Do not exceed the maximum working pressure or temperature rating of the lowest rated system
component. See Technical Data in all equipment manuals.
•Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all
equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information
about your material, request MSDS forms from distributor or retailer.
•Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufacturer’s replacement parts only.
•Do not alter or modify equipment.
•Use equipment only for its intended purpose. Call your distributor for information.
•Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
•Do not kink or over bend hoses or use hoses to pull equipment.
•Keep children and animals away from work area.
•Comply with all applicable safety regulations.
TOXIC FLUID OR FUMES HAZARD
Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or
swallowed.
•Read MSDS’s to know the specific hazards of the fluids you are using.
•Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.
•Always wear impervious gloves when spraying or cleaning equipment.
312769D3
Warnings
WARNING
WARNINGWARNINGWARNING
MOVING PARTS HAZARD
Moving parts can pinch or amputate fingers and other body parts.
•Keep clear of moving parts.
•Do not operate equipment with protective guards or covers removed.
•Pressurized equipment can start without warning. Before checking, moving, or servicing equipment,
follow the Pressure Relief Procedure in this manual. Disconnect power or air supply.
PERSONAL PROTECTIVE EQUIPMENT
You must wear appropriate protective equipment when operating, servicing, or when in the operating
area of the equipment to help protect you from serious injury, including eye injury, inhalation of toxic
fumes, burns, and hearing loss. This equipment includes but is not limited to:
•Protective eyewear
•Clothing and respirator as recommended by the fluid and solvent manufacturer
•Gloves
•Hearing protection
4312769D
Feed Kit Models
Feed Kit Models
All kits fit drums or 20 gallon hoppers. Most packages include all air and fluid fittings and hoses. Approvals are only
for the pumps or agitator and not for the entire package.
Complete
Package
(fluid and air)Description
256274Agitator Kit with air
connection
256275T2 2:1 Ratio Transfer
Pump Kit
256276
Monark
®
5:1 Ratio
Pump Kit
256433*
President
®
10:1 Ratio
Pump
25623255 Gallon (200 Liter)
Drum Feed Kit,
includes agitator kit
256274 and 2:1 pump
kit 246275
25625555 Gallon (200 Liter)
Drum Feed Kit,
includes agitator
256274 and 5:1 pump
kit 246276
Maximum Air
Input Pressure
100 psi
(0.7 MPa, 7 bar)
180 psi
(1.2 MPa, 12 bar)
180 psi
(1.2 MPa, 12 bar)
90 psi
(0.62 MPa, 6.2 bar)
N/AN/A
N/AN/A
Maximum Fluid
Working
Pressure
N/A
405 psi
(2.8 MPa, 28 bar)
900 psi
(6.2 MPa, 62 bar)
900 psi
(6.2 MPa, 62 bar)
Approvals
(only for pumps and agitator)
0359II 1/2 G T3
ITS03ATEX11226
0359II 1/2 G T2
ITS03ATEX11228
0359II 1/2 G T2
ITS03ATEX11228
See pump and agitator
approvals above.
See pump and agitator
approvals above.
* Does not include air hose, air fittings, or strainer to connect to XM sprayer pump lower.
312769D5
Installation
Installation
Grounding
The equipment must be grounded. Grounding reduces
the risk of static and electric shock by providing an
escape wire for the electrical current due to static build
up.
Connect grounding wire to grounding screw (Z) on back
of XM sprayer or any earth ground.
Z
Install Feed Pump
NOTE: President 10:1 feed pump kit 256433 is only
recommended for drum feed applications and highly
viscous materials. Do not install in hoppers as this
will result in pulsation at the gun. See page 11 for
parts.
1. Refer to Setup instructions in pump manual before
installing in drum or hopper (H).
2. If installing either the pump in a drum, install pump
in drum and use bung adapter (B) to secure.
3. If installing the T2 pump in a hopper: Install T2
pump in lower ledge of hopper (H), and secure with
bung adapter (B).
1
8
7
B
H
FIG. 1: XM Sprayer
r_256275_312769_5A
ti18686a
T2 2:1 pump shown in 20 gallon hopper
4. If installing 5:1 pump in a hopper:
1
7
8
H
ti18687a
5:1 pump shown in 20 gallon hopper
a. Install 5:1 pump in lower ledge of hopper (H).
b. Drop in bung adapter (B).
c.Install spacer (C).
22
C
B
6312769D
Installation
d. Adjust pump so there is at least 2.5 in. (64 mm)
between the pump shoulder and the top of the
bung adapter (B).
e. Orient the two spacer halves on the pump shaft
so spacer contacts the pump shoulder.
f.Tighten the spacer using provided hardware.
g. Slide the pump down so that the pump shoul-
der, spacer, and bung adapter are in solid contact.
h. Rotate pump so outlet hose is aligned as
desired.
i.Thread bung adapter tight.
j.Tighten bung adapter bolt.
5. Connect swivel fitting (7) and fluid hose (8) to feed
pump fluid outlet.
6. Connect other end of fluid hose (8) to lower strainer
valve assembly (17).
Install Agitator
NOTICE
Keep agitator tightly mounted to hopper to prevent
damage to threads from vibration. Ensure that there
is no interference between base of hopper and shaft
of agitator.
1. Install agitator (A) in drum, or upper ledge of double
wall hopper (H), by screwing helix through hole and
screwing agitator housing into bung adapter (B).
a. If only using an agitator: Install nipple fitting (52)
and elbow fitting (53) into agitator air inlet.
Shown in 20 gallon hopper.
A
H
r_256274_312769_3A
52
53
54
B
10
11
12
17
8
r_256276_312769_4A
7. Connect elbow swivel fitting (10) and fitting (11) to
sprayer pump fluid inlet. Connect lower strainer
valve (17) and nipple (12) to fitting (11).
b.If using an agitator and a pump: Install nipple
(52), tee fitting (2), two nipples (3), elbow (53)
into agitator air inlet.
52
2
3
53
3
54
r_256274_312769_4A
2. Screw air line fitting (54) into elbow fitting (53).
312769D7
Installation
Connect Air Lines
Trapped air can cause the pump to cycle unexpectedly,
which could result in serious injury from splashing or
moving parts.
1. 5:1 Monark pump only: Install air regulator kit (22).
2. 10:1 President pump only: Remove 3/8 npt nipple
from air regulator kit (22). Install reducing nipple
(42) in air motor inlet and connect air regulator kit.
See page 11.
3. Shut off air valves (V) at feed pumps (1).
256276 5:1 Pump Kit Shown
1
V
22
6. If only using an agitator:
a. Connect air line (55) and coupler (56) into fitting
(54).
Shown in 20 gallon hopper.
A
B
H
52
53
54
56
55
r_256274_312769_2A
7. If using a feed pump and agitator:
a. For Monark 5:1 pump only: Interconnect tee fit-
ting (2) and quick disconnect fitting (23) on
pump with air hose (5).
256276 5:1 Pump Kit Shown
quick disconnect
5
r_256276_312769_2A
4. If only using a Monark 5:1 or T2 2:1 feed pump:
Install air line (5) with quick disconnect coupler provided.
5. For President 10:1 Pump only: connect air line and
quick disconnect coupler, not included, to air regulator (22).
Shown in 20 gallon hopper.
23
54
2
55
5
ti18688a
8312769D
b.For T2 2:1 pump only: Interconnect tee fitting (2)
and quick disconnect fitting (1b) on pump with
air hose (5).
256275 2:1 Pump Kit Shown
Shown in 20 gallon hopper.
1b
5
2
Operation
C
FIG. 3: XP70 Sprayer
55
8. Remove one cap (C) from the air manifold (M) on
the sprayer and the connect air line from the agitator
or pump.
5
r_256275_312769_3A
C
Flush Before Using Equipment
The equipment was tested with lightweight oil, which is
left in the fluid passages to protect parts. To avoid contaminating your fluid with oil, flush the equipment with a
compatible solvent before using the equipment. Refer to
the Flushing section in proportioner manual.
Operation
Refer to separate pump and agitator manuals for operation and maintenance instructions.
Troubleshooting/Repair
See supplied pump manual and agitator manual for
maintenance, troubleshooting, and repair procedures.
r_256275_312769_4A
F
IG. 2: XM Sprayer
312769D9
Parts
Parts
Feed Pump Kits
T2 2:1 Pump Kit 256275
Monark 5:1 Pump Kit 256276
1
1
8
7
1a
1b
3
8
5
7
22
23
24
3
1
2
1
3
1
5
3
1
2
1
Sprayer Pump Inlet Connection
10
11
12
r_256275_312769_4
r_256275_312769_1
17
3
1
r_256275_312769_7A
1
Only used when agitator is used with pump. See page 12.
8
10312769D
Parts
Feed Pump Kit Parts
These parts are used in the T2 2:1 Pump Kit 256275
and Monark 5:1 Pump Kit 256276.
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in
material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty
published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by
Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written
recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of
non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with
structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or
maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of
the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned
to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will
be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED
TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or
consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT
MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to
the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these
warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or
the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the
negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into,
given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la
rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite
de ou en rapport, directement ou indirectement, avec les procédures concernées.
Graco Information
For the latest information about Graco products, visit www.graco.com.
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.
Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505
All written and visual data contained in this document reflects the latest product information available at the time of publication.
GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA
Copyright 2009, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
Graco reserves the right to make changes at any time without notice.
For patent information, see www.graco.com/patents.
Original instructions. This manual contains English. MM 312769
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
www.graco.com
Revised 02/2012
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.