Graco 310657J User Manual

Instructions – Parts List
Replacement PC Board Kit for: Ultra Max II 695/795/1095/1595t Ultimate Mx II 695/795/1095/1595t Mark IV, TexSprayt Mark V
Standard/
Vac Model
695 Standard 248037 248036 826048 826047
120 795 Standard 248308 248038 826049
North America Premium 248033 248032 826042
1095 Standard 248039 826050
1595 Standard 248040*
Mark V 249029*
Mark IV 249636*
240 695 248042 248041
Europe 795 248043
1095 248044
Mark V 249031
240 695 248046 248045
Europe Multi-cord 795 248047
1095 248048
Mark V 249178
110 695 248049 UK 795 248050
1095 248051
Mark V 249072
240 695 248593 248592
Australia 795 248594
1095 248595
240 695 248058 248057
Asia 795 248059
1095 248060
100 695 248053 248052
Japan & Taiwan 795 248055 248054
1095 248056
* Not ETL approved All models not available in all countries.
Premium
Ultra Max II Ultimate Mx II
Premium 248031 248030 826041 826040
Premium 248034 826044
248747
Premium 248035*
248746
310657J
826051* 826054
826045* 826053
249030
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441
Copyright 2004, Graco Inc. is registered to I.S. EN ISO 9001
Pressure Relief Procedure
WARNING
SKIN INJECTION HAZARD
System pressure must be manu­ally relieved to prevent system
from starting or spraying acciden­tally. Fluid under high pressure can be in­jected through skin and cause serious injury. To reduce risk of injury from injection, splash­ing fluid, or moving parts, follow Pressure Relief Procedure whenever you:
D are instructed to relieve pressure, D stop spraying, D check or service any system equipment, D or install or clean spray tip.
Installation
1. Turn pressure to zero.
2. Turn ON/OFF switch to OFF.
3. Unplug power supply cord.
4. Hold metal part of gun firmly to grounded metal pail. Trigger gun to relieve pressure.
5. Lock gun safety latch.
6. Open pressure drain valve. Leave pressure drain valve open until ready to spray again.
If suspected that spray tip or hose is completely clogged, or that pressure has not been fully relieved after following steps above, VERY SLOWLY loosen tip
guard retaining nut or hose end coupling to relieve pressure gradually, then loosen completely. Now clear tip or hose obstruction.
795 EXAMPLE SHOWN
R125
1095 795 695
ti4413b
Fig. 1
R126
695 795 1095 1595*
Mark V
* Available as 120 Vac sprayers only
R127
Cutting Instructions X = Remove
XX
XX
XX
XX X X
X
R127R125 R126
X
1. Follow Pressure Relief Procedure.
CAUTION
Electrostatic discharges can damage components on PC board. Use a ground strap when handling or installing PC board.
Using configurations other than those specified in Fig. 1 results in poor sprayer performance.
TO PLACE AN ORDER OR FOR SERVICE, contact your Graco distributor, or call 1–800–690–2894 to identify the nearest distributor.
2. Remove PC board. See Manual 309941 or 309942 for procedure.
3. Fig. 1. Cut resistors from PC board.
4. Install PC board. See Manual 309941 or 309942 for procedure.
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441
International Offices: Belgium, China, Japan, Korea
Graco Headquarters: Minneapolis
www.graco.com
1/2004, Rev 4/2007
2 310657
Loading...