•Allows use of e xte rnal air s upply for gre a te r a ir a tom iza tion at spray gun
•Bypa s s e s RTX inte rn a l air s upply
•Re quires a ir supply minimum of 10 cfm @ 100 ps i
Patent Pending
125 psi (0.7 MPa, 6.9 bar) Maximum Working Pressure
Important Safety Instructions
Read all warnings and instructions in the RTX
Spra ye r operation manual. Save the s e ins tru ction s .
CAUTION
• Connecting e xte rnal air s upply in any manner oth e r
tha n following these ins tructions ca n dam a ge sp ra ye r.
• Use cle a n, re gulated e xte rnal air s upply.
EN
ti12373a
Page 2
Installation and Operation
Installation and Operation
Installation
1. Remove hopper and front shroud (see manual
310645).
2.Install va lve.
3. Push fitting ring (A) and disconne ct air line (B).
B
A
4.Cut off 2 in. of a ir line (B) to a vo id contact with
moving pa rts .
5. Align elbow fitting (3) with hole on sprayer frame
and mount auxiliary a ir kit underneath sprayer
frame. Tighte n two scre ws (18) to s e cure in place .
18
3
6. Connect air line (B) to TEE connector (16) and air
compressor. Connect line (M) to elbow fitting (K)
and TEE connector (16).
M
7. Install front shroud and hopper.
B
16
2310694D
Page 3
Operation
Installation and Operation
1. Connect external air supply (C) to male air fitting
valve (D).
2. Connect spray gun a ir line (E) to valve (F).
3.Open spra y gun a ir valve (G) a ll the wa y.
G
D
Air Ve nt
F
E
H
C
4.Pull spra y gun trigger and a djust air flow with air
pre s s ure re gulator (H) (not supplied by Graco) on
external air supply.
5.Use s pray gun air va lve (G) for fine adjus tment.
Air Flow (cfm) Ope rating Ra nge a t gun
Connection J1 - 6 cfm
(no a dditional air re qu ired )
Connection F5 - 20 cfm
(require men t e xte rna l a ir supp ly)
ti4962b
310694D3
Page 4
Troubleshooting
Troubleshooting
PROBLEMCAUSESOLUTION
Spra ye r will not pump
ma te rial
Spra ye r will not stop
pumping material
Not enough atomiza tion
air at spray gun
Gun air va lve (G) not ope n comple te ly1.Open gun a ir va lve (G).
2.Re gulate a ir flow with air regula tor.
Dirty externa l air supplySee Maintena nce .
See Manua l 310645 for further troubleshooting Determine cause.
Spra y gun or a ir line leaking air when gun trigge r is c los ed
ti4964b
Air is venting when s pray gun is shut off
Compressor not large enough for intende d use 1. Open gun air valve (G).
Plugged gun, air line or valveRepair or clean as needed.
Mate rial not appropriate for systemRe view materia l spe cifications.
Air lines not properly connectedConnect air lines as shown on page 2.
Air Ve nt
Repair leak.
See Maintena nce .
2.Re gulate a ir flow with a ir re gu lato r (H).
Maintenance:
Clean valve inlet every 100 hours:
1.Re move fitting (8) and pis ton va lve (11).
2.Rins e out valve (10) with warm water.
3. Install piston valve (11) and fitting (8); hand tighten.
4310694D
Page 5
Parts
Parts
3
6
7
16
5
9
18
Ref. PartDescriptionQty.
1100175COUPLING, pipe1
2110249ADAPTER, male elbow, 90 degree1
3113321FITTING, e lbow tube1
4116720COUPLER, quick-disconnect1
5115524GASKET1
6119362FITTING, bu s hing1
7119373SP RING, compress ion1
815E090 FITTING, quick-dis conn ect, ma le1
915E127 NEEDLE, va lve1
1015E128 VALVE1
1115E129P ISTON, va lve1
1217U290 NUT, seal1
15110782o-ring1
1615E510TEE , with air lines1
17100016WASHER, lock2
18100270SCREW, cap, hex hd2
17
10
12
2
11
1
15
4
8
ti5111b
310694D5
Page 6
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
International Offices: Belgium, China, Japan, Korea
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441
Copyright 2008, Grac o Inc. is re gis te red to I.S. EN ISO 90 01
This manual contains English. MM 310694
Graco Headquarters: Minne a polis
www.grac o.com
Re vision D, 11/2018