Automatic system for fluid management of single component coatings. Includes flow
control, flushing, and color change. For professional use only.
Approved for use in explosive atmospheres (except the EasyKey).
Important Safety Instructions
Read all warnings and instructions in this
manual. Save these instructions.
1KS
See pages 4-5 for model information, including maximum working pressure. Equipment approval labels are
on page 3. Some components shown are not included
with all systems.
3A1080ProControl 1KS Operation
3A1164ProControl 1KS Repair-Parts
312782Dispense Valve
312783Color Change Valve Stacks
312787Color Change Module Kit
312784Gun Flush Box Kits
310745Gun Air Shutoff Kit
312786Dump Valve and Third Purge Valve Kits
312785Network Communication Kits
308778G3000/G3000HR/G250/G250HR Flow
Meter
313599Coriolis Flow Meter
313212Gun Flush Box Integration Kit
313290Floor Stand Kit
313542Beacon Kit
313386Basic Web Interface/Advanced Web
Interface
40680015V825 Discrete I/O Board Kit
Equipment Approvals
Equipment approvals appear on the following labels
which are attached to the Fluid Station Control Box and
™
EasyKey
EasyKey and Fluid Station Control Box Label
. See FIG. 1 on page 4 for label locations.
ATEX Certificate is listed here
ProControl 1KS
Electronic Proportioner
FM08ATEX0074
II 2 G
Ex ia IIA T3
CUS
Intrinsically safe
equipment for Class I,
Div 1, Group D, T3
Ta = -20°C to 50°C
MAX AIR WPR
.77100
MPabarPSI
MAX FLUID WPR
13.1190
1.31
MPabarPSI
MAX TEMP 50°C (122°F)
Intrinsically Safe (IS) System. Install
per IS Control Drawing No. 289833.
EasyKey Interface IS Associated
Apparatus for use in non hazardous
location, with IS Connection to Smart
Fluid Plate IS
Apparatus for use in:
Class I, Division 1, Group D T3 C
Hazardous Locations
Read Instruction Manual
Warning: Substitution of components
may impair intrinsic safety.
PART NO. SERIES
MFG. YR.
Fluid Station Control Box Label
SERIAL
GRACO INC.
P.O. Box 1441
Minneapolis, MN
55440 U.S.A.
ProControl
PART NO.SERIESSERIAL
Intrinsically safe equipment
for Class I, Div 1, Group D, T3
Ta = -20°C to 50°C
Install per 289833
ATEX Certificate is listed here
EasyKey Label
ProControl 1KS
PART NO.
SERIES NO. MFG. YR.
277869
GRACO INC.
P.O. Box 1441
Minneapolis, MN
55440 U.S.A.
Intrinsically safe connections
for Class I, Div 1, Group D
CUS
Ta = -20°C to 50°C
Install per 289833
Um: 250 V
ATEX Certificate is listed here
FLUID PANEL
MAX AIR WPR
.77100
MPabarPSI
FM08ATEX0073
II 2 G
Ex ia IIA T3
POWER REQUIREMENTS
VOLTS
AMPS
II (2) G
[Ex ia] IIA
FM08ATEX0072
GRACO INC.
P.O. Box 1441
Minneapolis, MN
55440 U.S.A.
85-250 ~
2 AMPS MAX
50/60 Hz
3A1163A3
System Configuration and Part Numbers
System Configuration and Part Numbers
Models
The part number for your equipment is printed on the equipment identification labels. See FIG. 1 for
location of the identification labels.
MeterFlow Control
Part No.SeriesDescription
262380
262381
262382
262383
Label Location
AProControl 1KS
AProControl 1KS
AProControl 1KS
AProControl 1KS
ProControl 1KS
Electronic Proportioner
on Fluid Station
Control Box
Maximum Fluid
Working Pressure
is listed here
TI15974a
FM08ATEX0074
II 2 G
Ex ia IIA T3
MAX AIR WPR
.77100
MPabarPSI
MAX FLUID WPR
1.31
MPabarPSI
MAX TEMP 50°C (122°F)
CUS
Intrinsically safe
equipment for Class I,
Div 1, Group D, T3
Ta = -20°C to 50°C
13.1190
NoneG3000CoriolisNoYes
✔
✔
✔✔
✔✔
✔✔
Intrinsically Safe (IS) System. Install
per IS Control Drawing No. 289833.
EasyKey Interface IS Associated
Apparatus for use in non hazardous
location, with IS Connection to Smart
Fluid Plate IS
Apparatus for use in:
Class I, Division 1, Group D T3 C
Hazardous Locations
Read Instruction Manual
Warning: Substitution of components
may impair intrinsic safety.
PART NO. SERIES
SERIAL
Label Location
on EasyKey
TI15975a
Part Number
MFG. YR.
GRACO INC.
P.O. Box 1441
Minneapolis, MN
55440 U.S.A.
FIG. 1: Identification Label, ProControl 1KS Systems
43A1163A
System Configuration and Part Numbers
Hazardous Location Approval
Models using a G3000, G3000HR, or intrinsically safe Coriolis meter for both A and B meters are approved for
installation in a Hazardous Location - Class I, Div I, Group D, T3 or Zone I Group IIA T3.
Maximum Working Pressure
Maximum working pressure rating is dependent on the fluid component options selected. The pressure rating is
based on the rating of the lowest rated fluid component. Refer to the component pressure ratings below.
Example: Model 262383 has a maximum working pressure of 190 psi (1.31 MPa, 13.1 bar).
Check the identification label on the EasyKey or fluid station for the system maximum working pressure.
See F
IG. 1.
ProControl Fluid Components Maximum Working Pressure
Base System (no meter, no color/catalyst change option,
EasyKey with LCD
RS 485 Network Cable, 50 ft (15.25 m)
Fiber Optic and Power Cables, 50 ft (15.25 m)
Fluid Station Control Box
Discrete I/O Board
A Side Dump Valve, if color valve(s) selected
Flow Control with 15 ft (4.57 m) Cable (if selected)
Basic Web Interface
Accessory
15V536 Solvent Flow Switch Kit
15V213 Power Cable, 100 ft (30.5 m)
15G710 Fiber Optic Cable, 100 ft (30.5 m)
15G614 Flow Control Extension Cable, 40 ft (12.2 m)
15W034 Strobe Light Alarm Indicator Kit
15V331 Gateway Ethernet Communication Kit
15V963 Gateway DeviceNet Communication Kit
15V964 Gateway Profibus Communication Kit
15V337 Advanced Web Interface
3A1163A5
Warnings
Warnings
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When
these symbols appear in the body of this manual, refer back to these Warnings. Product-specific hazard symbols and
warnings not covered in this section may appear throughout the body of this manual where applicable.
WARNING
FIRE AND EXPLOSION HAZARD
Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help
prevent fire and explosion:
• Use equipment only in well ventilated area.
• Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic
drop cloths (potential static arc).
• Keep work area free of debris, including solvent, rags and gasoline.
• Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes
are present.
• Ground all equipment in the work area. See Grounding instructions.
• Use only grounded hoses.
• Hold gun firmly to side of grounded pail when triggering into pail.
• If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment
until you identify and correct the problem.
• Keep a working fire extinguisher in the work area.
ELECTRIC SHOCK HAZARD
This equipment must be grounded. Improper grounding, setup, or usage of the system can cause
electric shock.
• Turn off and disconnect power at main switch before disconnecting any cables and before servicing
equipment.
• Connect only to grounded power source.
• All electrical wiring must be done by a qualified electrician and comply with all local codes and
regulations.
INTRINSIC SAFETY
Intrinsically safe equipment that is installed improperly or connected to non-intrinsically safe equipment
will create a hazardous condition and can cause fire, explosion, or electric shock. Follow local
regulations and the following safety requirements.
• Only models with a G3000, G250, G3000HR, G250HR, or intrinsically safe Coriolis meter are
approved for installation in a Hazardous Location - Class I, Div I, Group D, T3 or Zone I Group IIA
T3.
• Do not install equipment approved only for a non-hazardous location in a hazardous area. See the
ID label for the intrinsic safety rating of your model.
•Do not substitute or modify system components as this may impair intrinsic safety.
63A1163A
Warnings
WARNING
SKIN INJECTION HAZARD
High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like
just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment.
• Do not spray without tip guard and trigger guard installed.
• Engage trigger lock when not spraying.
• Do not point gun at anyone or at any part of the body.
• Do not put your hand over the spray tip.
• Do not stop or deflect leaks with your hand, body, glove, or rag.
• Follow the Pressure Relief Procedure when you stop spraying and before cleaning, checking, or
servicing equipment.
• Tighten all fluid connections before operating the equipment.
• Check hoses and couplings daily. Replace worn or damaged parts immediately.
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
• Do not operate the unit when fatigued or under the influence of drugs or alcohol.
• Do not exceed the maximum working pressure or temperature rating of the lowest rated system
component. See Technical Data in all equipment manuals.
• Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all
equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information
about your material, request MSDS from distributor or retailer.
• Do not leave the work area while equipment is energized or under pressure. Turn off all equipment
and follow the Pressure Relief Procedure when equipment is not in use.
• Check equipment daily. Repair or replace worn or damaged parts immediately with genuine
manufacturer’s replacement parts only.
• Do not alter or modify equipment.
• Use equipment only for its intended purpose. Call your distributor for information.
• Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
• Do not kink or over bend hoses or use hoses to pull equipment.
• Keep children and animals away from work area.
• Comply with all applicable safety regulations.
3A1163A7
Warnings
WARNING
TOXIC FLUID OR FUMES HAZARD
Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or
swallowed.
• Read MSDSs to know the specific hazards of the fluids you are using.
• Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.
• Always wear chemically impermeable gloves when spraying, dispensing, or cleaning equipment.
PERSONAL PROTECTIVE EQUIPMENT
You must wear appropriate protective equipment when operating, servicing, or when in the operating
area of the equipment to help protect you from serious injury, including eye injury, hearing loss,
inhalation of toxic fumes, and burns. This equipment includes but is not limited to:
• Protective eyewear, and hearing protection.
• Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer.
83A1163A
Important Two-Component Material Information
Important Two-Component Material Information
Isocyanate Conditions
Spraying or dispensing materials containing isocyanates creates potentially harmful mists, vapors, and
atomized particulates.
Read material manufacturer’s warnings and material MSDS to know specific hazards and precautions
related to isocyanates.
Prevent inhalation of isocyanate mists, vapors, and
atomized particulates by providing sufficient ventilation in the work area. If sufficient ventilation is not
available, a supplied-air respirator is required for
everyone in the work area.
To prevent contact with isocyanates, appropriate
personal protective equipment, including chemically
impermeable gloves, boots, aprons, and goggles, is
also required for everyone in the work area.
Material Self-ignition
Moisture Sensitivity of
Isocyanates
Isocyanates (ISO) are catalysts used in two component
coatings. ISO will react with moisture (such as humidity)
to form small, hard, abrasive crystals, which become
suspended in the fluid. Eventually a film will form on the
surface and the ISO will begin to gel, increasing in viscosity. If used, this partially cured ISO will reduce performance and the life of all wetted parts.
NOTE: The amount of film formation and rate of crystallization varies depending on the blend of ISO, the
humidity, and the temperature.
To prevent exposing ISO to moisture:
•Always use a sealed container with a desiccant
dryer in the vent, or a nitrogen atmosphere. Never
store ISO in an open container.
•Use moisture-proof hoses specifically designed for
ISO, such as those supplied with your system.
•Never use reclaimed solvents, which may contain
moisture. Always keep solvent containers closed
when not in use.
•Never use solvent on one side if it has been contaminated from the other side.
•Always lubricate threaded parts with ISO pump oil
or grease when reassembling.
Some materials may become self-igniting if applied
too thickly. Read material manufacturer’s warnings
and material MSDS.
Keep Components A and B
Separate
Cross-contamination can result in cured material in
fluid lines which could cause serious injury or damage equipment. To prevent cross-contamination of
the equipment’s wetted parts, never interchange
component A (isocyanate) and component B (resin)
parts.
3A1163A9
Changing Materials
•When changing materials, flush the equipment multiple times to ensure it is thoroughly clean.
•Always clean the fluid inlet strainers after flushing.
•Check with your material manufacturer for chemical
compatibility.
•Most materials use ISO on the A side, but some use
ISO on the B side.
Component Identification and Definition
Component Identification and Definition
See Table 1, and FIG. 2 for the system components.
FO*
EK
ST
PS*
ACV
CCM
Purge
Air
Logic Air
Air Control
Module
Regulator
V/P Air
Fluid
FC Cable*
FC (see
F
IG. 8)
MAFM (see
F
IG. 6)
*See the ProControl 1KS
Repair-Parts manual for
optional cable lengths.
F
IG. 2. ProControl 1KS System, shown with G3000 Meter, Color Change, and Flow Control
TI15961b
Table 1: Component Descriptions
ComponentDescription
EasyKey (EK)
Used to set up, display, operate, and monitor the system. The EasyKey accepts 85-250
VAC, 50/60 Hz line power and converts that power to acceptable low voltage and optical
signals used by other system components.
Fluid Station
Includes air control solenoids. Its control board manages all fluid functions.
Control Box (ST)
103A1163A
Table 1: Component Descriptions
ComponentDescription
Component Identification and Definition
Fluid Manifold (FM)
Flow Meters (MA,
MS)
Color Change
Valves (ACV) and
Color Change
Module (CCM)
Includes wall mounting bracket and mountings for the fluid meter and the following valves:
•Pneumatically Operated Dose Valve for component A
•Purge Valves for solvent and air purge
Four optional flow meters are available from Graco:
•G3000 is a general purpose gear meter typically used in flow ranges of 75-3800
cc/min. (0.02–1.0 gal/min.), pressures up to 4000 psi (28 MPa, 276 bar), and viscosities of 20–3000 centipoise. The K-factor is approximately 0.119 cc/pulse.
•G3000HR is a high resolution version of the G3000 meter. It is typically used in flow
ranges of 38–1900 cc/min. (0.01–0.5 gal/min.), pressures up to 4000 psi (28 MPa,
276 bar). and viscosities of 20–3000 centipoise. The K-factor is approximately 0.061
cc/pulse.
•S3000 is a gear meter used for solvents in flow ranges of 38-1900 cc/min. (0.01–0.50
gal/min.), pressures up to 3000 psi (21 MPa, 210 bar), and viscosities of 20–50 centipoise. The K-factor is approximately 0.021 cc/pulse.
•Coriolis is a specialty meter capable of a wide range of flow rates and viscosities.
This meter is available with 1/8 in. or 3/8 in. diameter fluid passages. For detailed
information on the Coriolis meter, see manual 313599.
The K-factor is user-settable; at lower flow rates use a lower K-factor.
➜ 1/8 in. fluid passages: set K-factor to .020 or .061.
➜ 3/8 in. fluid passages: set K-factor to .061 or 0.119.
An optional component. It is available as a color change valve stack for either low or high
pressure with up to 30 color change valves. Each stack includes one additional valve for
solvent to clean the fluid line between color changes.
Dual Fiber Optic
Cable (FO)
Fluid Station
Control Box Power
Supply Cable (PS)
Flow Control
Regulator
Assembly (FC)
Used to communicate between the EasyKey and Fluid Station Control Box.
Used to provide power to the Fluid Station Control Box.
Includes an air operated fluid pressure regulator, fluid pressure sensor, voltage to air