This symbol alerts you to the possibility of serious
injury or death if you do not follow the instructions.
WARNING
EQUIPMENT MISUSE HAZARD
Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury.
INSTRUCTIONS
This equipment is for professional use only.
Read all instruction manuals, tags, and labels before operating the equipment.
Use the equipment only for its intended purpose. If you are uncertain about usage, call your Graco
distributor.
Do not alter or modify this equipment. Use only genuine Graco parts and accessories.
Check equipment daily. Repair or replace worn or damaged parts immediately.
Notice Symbol
NOTICE
This symbol alerts you to the possibility of damage to
or destruction of equipment if you do not follow the
corresponding instructions.
Do not exceed the maximum working pressure stated on the equipment or in the Technical Data
for your equipment. Do not exceed the maximum working pressure of the lowest rated component
in your system.
Use fluids and solvents which are compatible with the equipment wetted parts. Refer to the Tech-
nical Data section of all equipment manuals. Read the fluid and solvent manufacturer’s warnings.
Handle hoses carefully. Do not pull on hoses to move equipment.
Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not expose
Graco hoses to temperatures above 82C (180F) or below –40C (–40F).
Do not move or lift pressurized equipment.
Wear hearing protection when operating this equipment.
Comply with all applicable local, state, and national fire, electrical, and safety regulations.
3080482
WARNING
SKIN INJECTION HAZARD
Spray from the gun, hose leaks or ruptured components can inject fluid into your body and cause
extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin
can also cause serious injury.
Fluid injected into the skin might look like just a cut, but it is a serious injury. Get immediate surgi-
cal treatment.
Do not point the gun at anyone or at any part of the body.
Do not put your hand or fingers over the spray tip.
Do not stop or deflect leaks with your hand, body, glove or rag.
Do not “blow back” fluid; this is not an air spray system.
Always have the tip guard and the trigger guard on the gun when spraying.
Check the gun diffuser operation weekly. Refer to the gun manual.
Be sure the gun trigger safety operates before spraying.
Lock the gun trigger safety when you stop spraying.
Follow the Pressure Relief Procedure on page 7 if the spray tip clogs and before cleaning,
checking or servicing the equipment.
Tighten all fluid connections before operating the equipment.
Check the hoses, tubes, and couplings daily. Replace worn, damaged, or loose parts immediately.
Permanently coupled hoses cannot be repaired; replace the entire hose.
Use only Graco approved hoses. Do not remove any spring guard that is used to help protect the
hose from rupture caused by kinks or bends near the couplings.
MOVING PARTS HAZARD
Moving parts can pinch or amputate your fingers.
Keep clear of all moving parts when starting or operating the pump.
Before servicing the equipment, follow the Pressure Relief Procedure on page 7 to prevent the
equipment from starting unexpectedly.
3080483
WARNING
FIRE AND EXPLOSION HAZARD
Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and
result in a fire or explosion and serious injury.
Ground the equipment and the object being sprayed. Refer to Grounding on page 6.
If there is any static sparking or you feel an electric shock while using this equipment, stop spray-
ing immediately. Do not use the equipment until you identify and correct the problem.
Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid
being sprayed.
Keep the spray area free of debris, including solvent, rags, and gasoline.
Before operating this equipment, electrically disconnect all equipment in the spray area.
Before operating this equipment, extinguish all open flames or pilot lights in the spray area.
Do not smoke in the spray area.
Do not turn on or off any light switch in the spray area while spraying or while there are any fumes
in the air.
Do not operate a gasoline engine in the spray area.
TOXIC FLUID HAZARD
Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin,
inhaled, or swallowed.
Know the specific hazards of the fluid you are using.
Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local,
state and national guidelines.
Always wear protective eyewear, gloves, clothing and respirator as recommended by the fluid and
solvent manufacturer.
3080484
Installation
WARNING
Maximum Hydraulic Input Pressure
The maximum safe hydraulic input pressure to this
motor depends on the pressure rating of the displacement pump to which it is connected.
Refer to the lower manual and the pump manual
for the maximum fluid working pressure and the
ratio. Never exceed the maximum fluid working
pressure of the pump. Serious injury or damage to
the equipment may result.
WARNING
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 7.
Be sure you always shut off the supply line shutoff
valve (E) first, and then the return line shutoff
valve. This is to prevent overpressurizing the motor
or its seals. When starting up the hydraulic system,
open the return line shutoff valve first.
NOTICE
Keep the hydraulic system clean
To reduce the risk of damaging the hydraulic power
supply, blow out all hydraulic lines with air, flush
thoroughly with solvent, and then blow out with air
again before connecting the lines to the motor.
NOTICE
Recommended Hydraulic Oil
Use Graco-approved Hydraulic Oil, Part No. 169236
(5 gal) or 207428 (1 gal)) or a premium, ISO grade
46 petroleum-based hydraulic oil containing rust and
oxidation inhibitors and anti-wear agents.
Before using any other type of oil in this motor,
contact your Graco distributor. Unauthorized use of
lesser grade oil or substitutes may void the warranty.
Hydraulic Oil Working Temperature
The recommended hydraulic oil operating temperature is 80–115F (27–45C). The motor seals will
wear faster and leakage may occur if the pump is
operated at higher oil temperatures.
If the hydraulic oil temperature approaches 130F
(54C), check the hydraulic fluid supply cooling
system, filters, etc. and clean or repair as needed.
Refer to the complete pump manual for detailed installation information or contact your Graco distributor.
NOTE: A 1 in. npt seal (7) is supplied in a plastic bag
with the motor. Thread the seal onto the threads of
your hydraulic return line fitting (A). Thread the fitting
into the upper housing (53) and torque as needed.
Then tighten the seal (7) against the motor to provide a
secure seal. See Fig. 1.
53
A
Always plug the hydraulic inlets, outlets and lines
when disconnecting them to avoid introducing dirt
and other contaminants into the system.
Carefully follow the manufacturer’s recommendations
on reservoir and filter cleaning, and periodic changes
of hydraulic fluid.