Graco 222812, 222909 User Manual

Instructions–Parts List
19 LITER (5 GALLON)
Wiper Plates
Not approved to European explosive atmosphere requirements.
U.S. Patent No. 5,117,998
Important Safety Instructions
Read all warnings and instructions in this manual. Save these instructions.
See page 2 for Table of Contents and List of Models.
Model 222812
308049U
ENG
Model 222909
0212A
01115
Table of Contents
List of Models 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Symbols 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Warnings 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation (All Wiper Plates) 5. . . . . . . . . . . . . . . . . . . . .
Installation on a Ram
(Carbon Steel or Aluminum Plates) 6. . . . . . . . . . . . .
Installation on a Cart
(Carbon Steel or Aluminum Plates) 8. . . . . . . . . . . . .
Installation on a Ram (Stainless Steel Plates) 10. . . . .
Installation on a Cart (Stainless Steel Plates) 12. . . . . .
Parts Drawings and Lists 14. . . . . . . . . . . . . . . . . . . . . . .
Accessories 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Graco Standard Warranty 22. . . . . . . . . . . . . . . . . . . . . .
Graco Information 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
List of Models
Backup
Model No. Series Plate Material Wiper Material
222812 B Carbon Steel Buna-N UHMWPE 6–9 14 235516 B Carbon Steel PTFE-coated UHMWPE 6–9 15 222909 A Stainless Steel PTFE-coated UHMWPE 10–13 16–17 241081 A Carbon Steel Buna-N UHMWPE 6–9 18 918409 B Carbon Steel Buna-N UHMWPE 6–9 19 C50260 B Carbon Steel Buna-N UHMWPE 6–9 14
Material
Installation Pages Parts Pages
2 308049
Symbols
Warning Symbol
WARNING
This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions.
WARNING
EQUIPMENT MISUSE HAZARD
Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury.
INSTRUCTIONS
D This equipment is for professional use only.
D Read all instruction manuals, tags, and labels before operating the equipment.
D Use the equipment only for its intended purpose. If you are uncertain about usage, call your Graco
distributor.
D Do not alter or modify this equipment. Use only genuine Graco parts and accessories.
D Check equipment daily. Repair or replace worn or damaged parts immediately.
Caution Symbol
CAUTION
This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions.
D Use fluids and solvents which are compatible with the equipment wetted parts. Refer to the Tech-
nical Data section of all equipment manuals. Read the fluid and solvent manufacturer’s warnings.
D Comply with all applicable local, state, and national fire, electrical, and safety regulations.
MOVING PARTS HAZARD
Moving parts, such as the priming piston and wiper plate, can pinch or amputate your fingers.
D Keep clear of all moving parts when starting or operating the pump.
D Keep hands and fingers away from the priming piston during operation and whenever the pump is
charged with air.
D Keep your hands away from the wiper plate and the lip of the pail while the ram is operating.
D Before servicing the equipment, follow the Pressure Relief Procedure on page 5 to prevent the
equipment from starting unexpectedly.
308049 3
Notes
4 308049
Installation (All Wiper Plates)
Pressure Relief Procedure
WARNING
SKIN INJECTION HAZARD
The system pressure must be manually relieved to prevent the system from
starting or spraying accidentally. Fluid under high pressure can be injected through the skin and cause serious injury. To reduce the risk of an injury from injection, splashing fluid, or moving parts, follow the Pressure Relief Procedure whenever you:
D are instructed to relieve the pressure, D stop spraying/dispensing, D check or service any of the system equipment, D or install or clean the spray tip/nozzle.
1. Lock the gun/valve trigger safety.
2. Close the pump air bleed valve (required in your system).
3. Shut off the main air bleed valve (required in your system).
4. Unlock the gun/valve trigger safety.
5. Hold a metal part of the gun/valve firmly to the side of a grounded metal pail, and trigger the gun/valve to relieve pressure.
6. Lock the gun/valve trigger safety.
7. Open the drain valve (required in your system) and/or the pump bleeder valve, having a container ready to catch the drainage.
8. Leave the drain valve open until you are ready to spray again.
If you suspect that the spray tip/nozzle or hose is completely clogged, or that pressure has not been fully relieved after following the steps above, very slowly
loosen the tip guard retaining nut or hose end coupling and relieve pressure gradually, then loosen completely. Now clear the tip/nozzle or hose.
308049 5
Installation on a Ram
(Carbon Steel or Aluminum Plates)
Installation
Reference letters and numbers in the text refer to Figs. 1–4 and the Parts Drawings on pages 14–15.
WARNING
MOVING PARTS HAZARD
Moving parts can pinch or amputate your fingers. When the pump is operating and
when raising or lowering the ram, keep your fingers and hands away from the priming piston and the lip of the pail.
WARNING
To reduce the risk of serious injury, whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 5.
1. Relieve the pressure.
2. Install the wiper plate (A) onto the pump intake (B), with the wiper plate vent handle (C) facing the front of the ram. Secure by tightening the setscrew (3). See Fig. 1.
3. The wiper plate is supplied for use with 19 liter (5 gallon) straight sided pails, but it can be easily modified for use with tapered pails. See steps a and b.
b. To reinstall the spacer for use with a
straight sided pail, first make sure the large diameter of the spacer (19) is facing down. Work the spacer up over the wiper plate by hand, so it is completely above the flange (D) of the wiper plate. See Fig. 3. Then, working from the top, use a screwdriver to position the spacer between the flange (D) and the wipers (E). See Fig. 4.
4. Connect a 610 mm (24 in.), 1/4 in. (6.3 mm) OD nylon tube (F) with a 1/8 npt(f) fitting (H) from the ram’s air assist tube fitting (G) to the air assist check valve (21) on the wiper plate.
5. Refer to the separate ram and pump manuals for set-up and operating instructions.
Maintenance
If the wiper plate does not come out of the pail easily when the pump is being raised, the air assist tube (F), fitting (H), and check valve (21) may be plugged. This prevents air from reaching the underside of the plate to assist in raising it from the pail.
WARNING
a. To use the wiper plate with tapered pails,
the large spacer (19) must be removed. Work- ing from the bottom, use a screwdriver to pry the spacer loose. Work it upward so it is com­pletely above the flange (D) of the wiper plate. See Fig. 2. Next, by hand, angle the spacer and work it off the plate, pulling it down over the flange and bottom wipers (E). See Fig. 3. Save the spacer, as it is required for other applications.
6 308049
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 5.
Relieve the pressure. Refer to the Parts Drawings on pages 14–15 and disassemble the air assist check valve as shown. Clear the tube (F) and the port in the wiper plate. Clean all parts of the check valve assem­bly, and reassemble.
Installation on a Ram
A
(Carbon Steel and Aluminum Plates)
Installing the Wiper Plate on a Ram (Model 222812 shown; large diameter of spacer facing down)
To use Model 222812 and 235516, Plates with tapered
1
pails, the spacer (19) must be removed. See page 6, and Figs. 2–4.
Fig. 2
D
19
E
0248A
G
F
H
Fig. 1
D
19
E
C
B
0249A
Fig. 3
A
3
19 1
06540
Fig. 4
19
E
D
0251A
308049 7