Graco 222104-E, 222103-E, 222051-E User Manual

Instructions -- Parts List
1:1 RATIO
Fast-Ballt Pumps
For non--abrasive and non--corrosive oils and lubricants only.
180 psi (1.2 MPa, 12.4 bar) Maximum Air and Fluid Working Pressure
Oil Pumps
CAUTION
These pumps are designed to pump lubricating fluids only.
Universal Pump
307906W
EN
55-Gallon Drum, Bung-Mount Pump
275-Gallon Tank, Bung-Mount Pump
Important Safety instructions
Read all warnings and instructions in this manual. Save these instructions. See page 2 for Table of Contents.
Model 222051
05939B
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440- 1441
Copyright 1989, Graco Inc. is registered to I.S. EN ISO 9001
Models 222103
222104
05940B
Table of Contents
Warnings 2......................................
Installation 5.....................................
Operation 8.....................................
Troubleshooting 9................................
Service 10......................................
Parts List 12.....................................
Parts Drawing 13.................................
Dimensional Drawing 14..........................
Technical Data 14................................
Performance Curves 15...........................
Graco Standard Warranty 16......................
Graco Information 16.............................
WARNINGWARNING
Symbols
Warning Symbol
WARNING
This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions.
Caution Symbol
CAUTION
This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions.
EQUIPMENT MISUSE HAZARD
Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury.
D This equipment is for professional use only.
D Read all instruction manuals, tags, and labels before you operate the equipment.
D Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor.
D Do not alter or modify this equipment. Use only genuine Graco parts and accessories.
D Check equipment daily. Repair or replace worn or damaged parts immediately.
D Do not exceed the maximum working pressure of the lowest rated component in your system.
This equipment has a 180 psi (1.2 MPa, 12.4 bar) maximum working pressure at 180 psi (1.2 MPa, 12.4 bar) maximum incoming air pressure.
D Use fluids and solvents that are compatible with the equipment wetted parts. Refer to the Techni-
cal Data section of all equipment manuals. Read the fluid and solvent manufacturer’s warnings.
D Do not use 1,1,1--trichloroethane, methylene chloride, other halogenated hydrocarbon solvents,
or fluids that contain such solvents in pressurized aluminum equipment. Such use could result in a chemical reaction, with the possibility of explosion.
D Handle hoses carefully. Do not pull on hoses to move equipment.
D Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not ex-
D Do not lift pressurized equipment.
D Comply with all applicable local, state, and national fire, electrical, and safety regulations.
2 307906
pose Graco hoses to temperatures above 82_C (180_F) or below --40_C(--40_F).
WARNINGWARNING
SKIN INJECTION HAZARD
Fluid from the dispensing valve, leaks, or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury.
D If a fluid injection injury occurs, get immediate surgical treatment. Do not treat as a simple
cut. Tell the doctor exactly what fluid was injected.
D Do not point the dispensing valve at anyone or at any part of the body.
D Do not put your hand or fingers over the end of the dispensing valve.
D Do not stop or deflect leaks with your hand, body , glove, or rag.
D Use only extensions and no-drip tips that are designed for use with your dispensing valve.
D Do not use a low pressure flexible nozzle with this equipment.
D Follow the Pressure Relief Procedure on page 8 if the dispensing valve clogs before you
clean, check, or service the equipment.
D Tighten all fluid connections before you operate the equipment.
D Check the hoses, tubes, and couplings daily. Replace worn or damaged parts immediately. Do
not repair high pressure couplings; you must replace the entire hose.
TOXIC FLUID HAZARD
Hazardous fluids or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed.
D Know the specific hazards of the fluid you are using.
D Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local,
state and national guidelines.
D Always wear protective eyewear, gloves, clothing, and respirator as recommended by the fluid
and solvent manufacturer.
3307906
WARNINGWARNING
FIRE AND EXPLOSION HAZARD
Improper grounding, poor ventilation, open flames, or sparks can cause a hazardous condition and result in a fire or explosion and serious injury.
D Ground the equipment and the object being lubricated. See Grounding on page 6.
D If there is any static sparking or you feel an electric shock while using this equipment, stop
dispensing immediately. Do not use the equipment until you identify and correct the problem.
D Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid
being dispensed.
D Keep the dispensing area free of debris, including solvent, rags, and gasoline.
D Do not smoke in the dispensing area.
MOVING PARTS HAZARD
Moving parts can pinch or amputate your fingers or other body parts.
D Do not cycle the pump with any parts disassembled.
D Keep clear of all moving parts when you start or operate the pump.
D Before you service the equipment, follow the Pressure Relief Procedure on page 8 to prevent
the equipment from starting unexpectedly.
United States Government safety standards have been adopted under the Occupational Safety and Health Act. Y ou should consult these standards-- --particularly the General Standards, Part 1910.
4 307906
Installation
A
CD
B
F
E
P
Q
G
L
KEY
A Air shutoff valve B Air filter C Air regulator and gauge D Air motor lubricator E Bleed-type master air valve (required, Part No. 110223) F Air and fluid hose kits G Ground wire (required, Part No. 222011) H Fluid shutoff valve
Fig. 1
A
Main Air Line
Main Fluid Line
C
B
D E
F
P
Q
28
G
H
N
R
J
R
K
J Wall bracket K Universal pump (Model 222051) L Suction kit M 55-gallon drum bung-mount pump (Model 222103) N Fluid drain valve (required, Part No. 210658) P Air inlet Q Ball valve (for releasing collected moisture) R Thermal relief kit (required for permanent
installations, Part No. 237601)
28 Bung adapter
H
N
M
05942B
Install the accessories in the order shown in the typical installation in Fig. 1. The installation shown in Fig. 1 is only a guide for selecting and installing a pump; it is not an actual system design. Contact your Graco representative for assistance in designing a system to suit your needs.
NOTE: Blow out all lines with compressed air before you connect the pumps.
CAUTION CAUTION
Always mount the pump firmly to a wall bracket or a bung on a drum. Never operate the pump while it is not mounted. Such use could damage the pump and fittings.
Do not hang the air accessories directly on the air inlet (P). The fittings are not strong enough to support the accessories and may break. Provide a bracket on which to mount the accessories.
5307906
Loading...
+ 11 hidden pages