Graco 215963 User Manual

Instructions – Parts List
Fast-FloR Air Motor
12.5 bar (1.25 MPa, 180 psi) Maximum Air Working Pressure
Model 215963, Series A
101.6 mm (4 in.) stroke
NOTE: To replace Air Motor 215963, order Motor Replacement Kit 223099. See manual 307977 for parts.
Important Safety instructions
Read all warnings and instructions in this manual. Save these instructions. See page 2 for table of contents.
307456U
03652B
Model 215963 Shown
Table of Contents
Warnings 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operation 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Service 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Parts 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Symbols
Caution Symbol
CAUTION
This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions.
WARNING
EQUIPMENT MISUSE HAZARD
Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury.
INSTRUCTIONS
D This equipment is for professional use only.
Dimensional Drawings 10. . . . . . . . . . . . . . . . . . . . . . . . .
Mounting Hole Layout 10. . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Graco Warranty 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Graco Information 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Warning Symbol
WARNING
This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions.
D Read all instruction manuals, tags, and labels before operating the equipment.
D Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor.
D Do not alter or modify this equipment. Use only genuine Graco parts and accessories.
D Check equipment daily. Repair or replace worn or damaged parts immediately.
D Do not exceed the maximum working pressure stated on the equipment or in the Technical Data
section for your equipment. Do not exceed the maximum working pressure of the lowest rated component in your system.
D Handle hoses carefully. Do not use hoses to pull equipment.
D Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not expose
Graco hoses to temperatures above 66_C (150_F) or below –40_C (–40_F).
D Wear hearing protection when operating this equipment.
D Comply with all applicable local, state, and national fire, electrical, and safety regulations.
3074562
WARNING
SKIN INJECTION HAZARD
Spray from the gun, leaks, or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury.
D Fluid injected into the skin might look like just a cut, but it is a serious injury. Get immediate
surgical treatment.
D Do not point the gun at anyone or at any part of the body.
D Do not put your hand or fingers over the spray tip/nozzle.
D Do not stop or deflect leaks with your hand, body, glove, or rag.
D Always have the tip guard and the trigger guard on the gun when spraying.
D Be sure the gun trigger safety operates before spraying.
D Close the gun ball valves when you stop spraying.
D Lock the gun trigger safety when you stop spraying.
D Follow the Pressure Relief Procedure on page 5 if the spray tip/nozzle clogs and before clean-
ing, checking, or servicing the equipment.
D Tighten all fluid connections before operating the equipment.
D Check the hoses, tubes, and couplings daily. Replace worn or damaged parts immediately.
Do not repair high pressure couplings; you must replace the entire hose.
307456 3
WARNING
FIRE AND EXPLOSION HAZARD
Improper grounding, poor ventilation, open flames, or sparks can cause a hazardous condition and result in a fire or explosion and serious injury.
D Ground the equipment and the object being sprayed/dispensed. Refer to Grounding on
page 5.
D If there is any static sparking or you feel an electric shock while using this equipment, stop spray-
ing immediately. Do not use the equipment until you identify and correct the problem.
D Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid
being sprayed/dispensed.
D Keep the spray/dispensing area free of debris, including solvent, rags, and gasoline.
D Before operating this equipment, extinguish all open flames or pilot lights in the spray/dispensing
area.
D Do not smoke in the spray/dispensing area.
D Do not turn on or off any light switch in the spray/dispensing area while operating or if fumes are
present.
D Do not operate a gasoline engine in the spray/dispensing area.
TOXIC FLUID HAZARD
Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed.
D Know the specific hazards of the fluid you are using.
D Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local,
state, and national guidelines.
D Always wear protective eyewear, gloves, clothing, and respirator as recommended by the fluid and
solvent manufacturer.
3074564
Loading...
+ 8 hidden pages