Grace SuperPASS 3 User Information

. .
.
.
Grace Industries, Inc.
305 Bend Hill Road, Fredonia, PA 16124
Ph. 724-962-9231 Fax 724-962-3611
Front View with Accountability Key In Place
Safety Certifications
Certified Intrinsically Safe to ANSI/UL 913: Class 1, Groups C and D; and Class II, Groups E, F, and G; Division 1 Hazardous Locations.
CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
Warranty Information
Grace Industries, Inc. warrants the Super PASS®3 to be free from defects in workmanship and materials for a period of one year from the date of purchase. This warranty is valid only when the re­turned SuperPASS®3 is accompanied by a sales slip or other proof of purchase that states the date and location of purchase. Grace Industries, Inc. will not repair or replace any merchandise under war­ranty which has been damaged because of acci­dent, misuse or abuse of the SuperPASS®3 while in possession or control of the consumer. This war­ranty is void if any attempt to repair or replace parts was made or attempted by other than qualified Grace Industries, Inc. personnel. This warranty is void if any of the sealed compartments are opened or tampered with. Send all returned merchandise, prepaid and accompanied by proof of purchase to: Grace Industries, Inc., Repair Division, 305 Bend Hill Road, Fredonia, PA 16124. Grace Industries, Inc. shall not be liable for any direct, incidental or other consequential loss or damage arising out of the failure of the device to operate.
The sole and exclusive remedy under all guar­antees or warranties, expressed or implied, is strictly limited to repair or replacement as herein provided. ALL IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO, WARRANTIES OF FITNESS AND MERCHANTABILITY, ARE HEREBY LIMITED IN DURATION TO A PERIOD ENDING ONE (1) YEAR FROM THE DATE OF PURCHASE. The war­ranty and liability set forth in the prior paragraphs are in lieu of all other warranties, expressed or im­plied, in law or in fact, including implied warranties of merchantability and fitness for a particular pur­pose. Some states do not allow limitations on how long an implied warranty lasts, so the above limita­tions may not apply to you.
This warranty gives you specific legal rights and you may also have other rights which may vary from state to state.
The information contained in this booklet is be­lieved to be accurate and reliable. Grace Industries, Inc. provides this information as a guide only.
SuperPASS
®
3 technical assistance is available by contacting Grace Industries, Inc. at 724-962-9231.
SuperPASS®3 is designed to be automatically acti­vated into the Sensing Mode or turned ON when re­moved from the PASS storage position, whether it is a transportation or a fixed storage position. When removed from the storage position, the tether will tighten and the Accountability Storage Key will automatically pop off putting SuperPASS
®3
into the Sensing Mode. At this point, the unit can be reset (from the Alarm Mode to Sensing Mode) but cannot be turned OFF until the Accountability Storage Key is replaced and both side buttons pressed simultaneously.
The Accountability Storage Key has an adjustable tether for ease of use. The tether can be adjusted from approx. 3' to 6' in length. This allows for easy utilization whether you are anchoring the tether to a transporta­tion position (such as to a seat in a vehicle) or a fixed storage position (such as in the fire station). Account­ability Storage Keys are available with various length tethers to facilitate various operational needs.
Internal Datalogger
The internal data logging function records dates and times of the last 2,000 events. Recorded PASS events include: Power On, Pre-Alert and Lack of Motion Alarm, Manual Alarm, Reset, Power Off and Low Battery Warn­ings. The datalog information can be downloaded to a PC using the datalog-transfer software and IR Dongle available from Grace Industries.
IMPORTANT: To preserve the internal date & time setting when changing batteries - batteries must be replaced within 3 minutes of removing the exhausted set.
The clear Identification Window located on the front of the key provides the opportunity for specific identity of the PASS user through the ability to personalize keys with pictures, names, numbers, dept. ID, bar-codes, etc. The clear access window easily snaps into place to pro­tect enclosed information and provide instant access for quick ID. Information in the Identification Window can easily be changed by partially popping the ID window out with a small, flat blade screwdriver through the ac­cess slot located on the bottom of the ID window.
SUPER PASS® 3 with
Accountability Storage Key in Place
Pull Away Tether for Auto-On
Activation from Storage Positions
Snap hook attached to Transportation or Fixed
Storage Position.
Pull turnout gear away. Tether tightens and pulls Accountability Key off the PASS. This will automatically activate the PASS into the Sensing Mode.
PASS attached to turnout gear
Snap Hook
Changing identification information
in the Accountability Storage Key window
Push small screwdriver through slot on outside of key. The Plastic I.D. window will pop out. Add I.D. information and Snap window back in place.
Emergency Alarm Button
Auto-On Activation
Inside Battery Cover
Battery Chamber
Bottom View
Accountability Storage Key
Wire Attachment Clip
Side View With Accountability Key In Place
Sound Ports
SUPER PASS® 3
Features and Labeling
© Grace Industries, Inc. Printed in U.S.A. P/N SUPERPASS3 0510, UI
USER’S INFORMATION
Only To Be Removed By End User
Front View without Accountability Key
In Place
For training purposes a copy of this information is available by contacting Grace Industries, Inc.
SuperPASS
®
3 issues may be reported at any time to Grace Industries, Inc. at 724-962-9231. After working with the manufacturer to resolve any issues, they may be reported to SEI at 703-442-5732.
Case Glows when Accountability Key Pops Off
Emergency Alarm Button
Solutions for Life Safety
Solutions for Life Safety
1. To , press both side buttons simultaneously when Accountability Key is Off unit.
To turn , replace Accountability Key and press both side buttons simultaneously
Identification Window
Tether Attached To A Fixed Position
Serial Number Label
FIGURE 1
Sealing Surface
O-ring
I.D. Window
Compliance Label
Reset Label
SuperPASS
®
3
Battery Installation/ Replacement
To reduce the risk of ignition of a flammable atmosphere, batteries must only be changed in an area known to be non-flammable. To change batteries, remove the two screws securing the back. Remove back cover, discon­nect and dispose of the spent batteries and insert new batteries.
Important: To preserve the internal date & time setting, batteries must be replaced within 3 min­utes of removing the exhausted batteries.
Prior to replacing the back, apply a light coating of silicone grease to the O-ring. Then apply a light coat­ing of silicone grease to the inside (mating/sealing) edge of the case. As a guideline, when applying sili-
cone grease to the O-ring (and case), you should be able to feel grease on your fingers, and see a thin film on the O-ring and sealing surface of the case. Do not use an excessive amount of grease. Excess grease can attract dirt which could com­promise the battery compartment seal.
Line up the mating/sealing edges of the back and case. Carefully press the back into place. Secure back
by hand tightening both screws. Do not over tighten.
WARNING Always use the specified AA 1.5 volt al-
kaline battery. Duracell MN1500 is recommended for optimum performance, as other batteries may not pro­vide the same operating life. Replacing the batteries every six months is required unless indicated before by the Low Battery Alarm. The Low Battery Alarm will sound when the batteries have been exhausted to 20% of capacity (indicating approx. 1 hour operating time remains). Immediate replacement of the batteries is necessary when the low battery alarm sounds.
When the PASS is in Sensing Mode, the low bat­tery alarm is easily recognized by an alternating dis­play of green and yellow LEDs, accompanied by a series of two audio beep tones enunciated every 23 seconds. Grace Industries, Inc. assumes no liability for mechanical, electrical or other types of battery failure.
Warning - substitution of components may impair intrinsic safety. After battery replacement, always test SuperPASS
®
3 to insure proper operation.
SuperPASS®3
SuperPASS®3 Operating Instructions
SuperPASS®3 is an Auto On, Personal Alert Safety System (PASS). The Auto On fea-ture insures that the SuperPASS®3 is turned on “Auto­matically” when removed from a storage position.
When removed from a storage position, Super PASS
®
3 Accountability Storage Key automatically pops off, acti­vating the unit into Sensing Mode (motion sensing). When the SuperPASS
®
3 turns ON, an operational sig­nal (escalating series of loud, attention getting audio tones) will be heard, accompanied by a visual alternat­ing display of four green LEDs. The alternating display indicates that SuperPASS
®
3 is in the Sensing Mode. If the PASS is motionless for a few seconds, the green LEDs will cease the alternating display and flash into opposing corners until the PASS is moved or enters Pre-Alert.
After lack of motion for approximately 18 to 23 sec­onds, the unit will go into Pre-Alert and a 12 second sweeping Pre-Alert audio signal will be heard, accom­panied by an alternating green and yellow LED display. The longer the unit is in Pre-Alert, the louder the sweep­ing pre-alert signal becomes signifying the unit is closer to going into Alarm. When there is lack of motion for approximately 30 to 35 seconds, the unit will go into Alarm Mode. When in Alarm, the Pre-Alert LED dis­play is replaced by a rapid pulsing of four red LEDs accompanied by a rapid modulated loud audio Alarm signal. This alerts personnel in the immediate area that assistance may be needed.
While in Sensing Mode, SuperPASS
®3
may be put into Alarm at any time by manually pressing the alarm button located on front surface of unit. Once in alarm, the unit can be reset or returned to the Sensing Mode by simply pressing both side buttons simultaneously. To turn SuperPASS
®3
OFF, replace the Accountability
Storage Key and press both side buttons simultaneously.
Accountability Key
An added benefit of the Grace PASS is the Account­ability Storage Key. The clear Identification Window pro­vides the opportunity for specific identity of a SuperPASS
®
3 user through the ability to personalize keys with pictures, names, numbers, dept. ID, bar-codes, etc. The clear access window easily snaps into place to protect enclosed information and provide instant access for quick identification should the need arise.
SuperPASS®3 should be securely attached to a ver-
tical strap on the upper left or right shoulder, in the horizontal position with the sound port facing out to the side or on the right hip area (See Figure 1).
Each member involved in rescue, fire suppression, or other hazardous duties shall be provided with and shall use a PASS device in the hazardous area1500. All personnel should be thoroughly
familiar with and trained in proper op-eration of SuperPASS® 3 prior to field use. Always test SuperPASS®3 prior to use. Failure to do so may expose the user to serious injury or loss of life.
Limitations
SuperPASS® 3 is engineered to meet the design and performance requirements for personal alert safety sys­tems (PASS) to be used by firefighters engaged in res­cue, fire fighting and other hazardous duties.
Failure to ensure that SuperPASS® 3 is fully operational prior to use, may expose the user to serious injury or loss of life. There is no inherent guarantee against PASS failure. Even the best PASS cannot com­pensate for abuse or lack of a PASS training and mainte­nance program.
Although SuperPASS
®
3 can be checked for proper
operation, most performance properties of the PASS
cannot be tested by the end user in the field.
SuperPASS
®
3 Maintenance
SuperPASS
®3
requires minimum maintenance and will
provide years of service.
Please Observe The Following Guidelines
• At the end of each use, clean unit with a damp cloth
and warm water. Do not use cleaning solvents.
• Inspect unit for signs of physical damage.
• Store SuperPASS
®
3 in a dry, well ventilated area consistent with battery manufacturer requirements. Recommended storage conditions are: 50oF (10oC) to 77oF (25oC) at no more than 65 percent relative humidity.
• Units contaminated by chemical or radioactive materials must be disposed of or decontaminated in accordance with all applicable regulatory standards.
• Replace batteries approximately every 6 months or sooner if indicated by Low Battery Alarm.
• Do not mark or apply paint to case or silicone cover.
SuperPASS®3 - Specifications
Dimensions: 3" wide by 4-9/16" high by 2-5/16" deep.
Weight: 16 ounces with batteries (w/out key).
Alarm Audio Output: 95+ dBA @9.9 feet.
Case: rugged, high temperature, impact resistant, trans-
lucent, yellow colored Radel encapsulated in a durable, translucent, high-temp silicone cover. Entire case glows during Sensing, Pre-Alert, and Alarm Modes.
Methods of Attachment: wire attachment clip.
Sound Discernability: 6 dBA against given background
noise.
Batteries: 4 Duracell MN1500, AA, 1.5 volt alkaline rec­ommended.
Battery Life: estimated at 200 hours in Sensing Mode, 2 to 4 hours in ALARM Mode and approximately 6 months in Standby (Storage) Mode.
Model Designation: SuperPASS
®
3 Motion Only-Black
triangle label below number 3. SuperPASS
®
3 Lack of Motion and Temperature-Red triangle label below number 3.
Product Life: Approx. 3 to 7 years or longer depend­ing on fitness for use. Fitness for use is best deter­mined by the end user through a proper inspection and maintenance program. Product should be retired from service when damaged or determined unfit for use.
SuperPASS
®
3 Visual / Audio Mode Display
OFF
- Accountability key in place with no LED display.
ON
- Accountability key removed, a series of escalat­ing, loud, attention getting audio tones.
- Followed by a green alternating LED display.
Pre-Alert
- No motion sensed for 18 - 23 seconds.
- Green and Yellow alternating LED display.
- Accompanied by a progressively louder, sweeping audio signal between 1,000 Hz and 2,000 Hz.
Alarm
- No motion sensed for 30 - 35 seconds.
- Green alter nating LED display is replaced by rapid pulsing of four Red LEDs.
- Accompanied by a rapid, modulated, loud ( 95+dBA ) audio alarm.
- The alarm signal is made up of multiple frequencies between 500Hz and 4000Hz and cycles at 5.25 seconds On and 0.75 seconds Off as an aid in determing direction when assistance is needed.
SuperPASS®3 Mode Selection
Auto-On
- From Off to Sensing Mode.
- When removed from storage position, Accountability Storage Key pops off and Sensing
Mode is activated.
Sensing
- Green alter nating LED display
- Unit is in Sensing Mode or ON.
Alarm
- Unit may be put into Alarm from the Sensing Mode or Off Mode at any time by pressing the
button on front of unit.
Reset
- When in Alarm , the unit may be reset to the Sensing mode by simultaneously pressing both
side buttons.
OFF
- Unit may be turned Off by replacing the Accountability key and simultaneously pressing both side buttons.
SuperPASS
®
3
with Temperature Sensing Option
SuperPASS
®
3 is equipped with an Integrated (in­ternal) Temperature Detector if the serial number ends in H or has a Red triangle label below the number 3 on front of case. You may also remove the Accountability key, press both side buttons and observe a momentary flash of red LEDs. The se­rial number is located in the battery compartment under the top battery.
The Integrated Temperature Detector alarm (a rapid ringing tone) should not be regarded as an absolute measure of existing temperatures. The temperature alarm may sound an alarm earlier or later with regards to integrated time/ temperature detection. The time variation is dependent upon where the unit is worn and the environmental con­ditions. When the temperature alarm threshold has been exceeded by exposure to extreme environ­mental conditions, the unit will sound the tempera­ture alarm audio tone with a specific LED display. The temperature alarm sound signature is a loud, piercing, rapid chirping tone accompanied by slow pulsing of 2 alternating yellow LEDs. The tempera­ture alarm can be temporarily silenced for one minute by pressing both side buttons simulta­neously while unit is in the sensing mode. The unit must cool down below the temperature alarm threshold to be silenced. SuperPASS
®
3 and the temperature alarm may be turned Off by replac­ing the accountability key and pressing both side buttons simultaneously.
Integrated Temperature Detection - Approximate Alarm Response Times:
350°F - 6 minutes 250°F - 9 minutes
300°F - 7 minutes 200°F - 12 minutes