GP Systems BioSmart PV-WTC-EM, BioSmart PV-WTC-MF, BioSmart PV-WTC-HD, BioSmart PV-WTC-LG Installation Manual

1
BioSmart PV-WTC Terminal
Installation guide
2
3
TABLE OF CONTENTS
GENERAL PRODUCT INFORMATION ..................................................................4
1.1 BioSmart PV-WTC models .........................................................................5
1.2 Basic specifications ...................................................................................5
1.3 Factory settings .........................................................................................6
1.4 Package contents .......................................................................................6
7.1 Description of terminal’s front panel ..........................................................8
7.2 Description of connection ports ................................................................10
7.3 Description of indicators and circuit board jumpers..................................11
8. INSTALLATION .....................................................................................................11
8.1 Installation notes ........................................................................................11
8.2 Installation procedure ................................................................................12
8.3 Connecting the terminal’s power supply ....................................................14
8.4 Connecting the terminal to an Ethernet network .......................................15
8.5 Connecting an electromechanical lock to the terminal’s circuit board......17
8.6 Connecting an electromagnetic lock through the BioSmart BCR ..............18
8.7 Connecting an entry sensor and control buttons ......................................19
8.8 Connecting to an external controller through Wiegand .............................20
9. CONFIGURING NETWORK PARAMETERS ............................................................21
10. ENSURING OF THE OPERATION ..........................................................................22
4
Dear customers!
Thank you for purchasing our product. With proper installation and use, this device will
bring you many years of reliable service.
GENERAL PRODUCT INFORMATION
The BioSmart PV-WTC work and attendance terminal is designed for use as part of the
BioSmart biometric access monitoring and control system. The terminal provides a means
to track working hours and attendance by identifying users through the unique biometric
characteristics of subcutaneous palm veins and RFID proximity cards. It can also be used
for access monitoring and control.
Compatible with BioSmart-Studio software version V5.0.3.269 and above.
Four models of this terminal are available:
- With Em-Marin (EM) card format scanner;
- With Mifare (MF) card format scanner;
- With HID iClass and HID Prox (HD) card format scanner;
- With Legic (LG) card format scanner.
5
1. SPECIFICATIONS
1.1 BioSmart PV-WTC models
Designation Device serial number
BioSmart PV-WTC-EM
BioSmart PV-WTC-MF
BioSmart PV-WTC-HD
BioSmart PV-WTC-LG
1.2 Basic specifications
Palm vein scanner type Optical, infrared
Maximum number of users* 1,000,000
Maximum number of card codes 1,000,000
Maximum number of palms
300,000
Maximum number of events
10,000,000
1:1000 vein matching identification time, sec
not longer than 2
False acceptance rate, % **
0.00008
Integrated RFID card scanner
Yes
Card scanning range, mm
up to 100
Display
TFT 3.5” 320х240
Keyboard
keypad, 12 buttons
BioSmart relay module support
Yes
Connection interface with computer
Ethernet
USB interface for configuration
USB 2.0
Web interface for configuration
Yes
Wiegand 26-40 bit output interface
Yes
On-board relay
12 VDC, 1 А
Number of discrete inputs, pcs
1
Power supply specifications
12 VDC±15%, 1 A
Outer dimensions (L x W x H), mm
215х150х117
Net weight, g
820
Gross weight, g
1270
Operating temperature range, °С
from 0 to plus 50
Operating relative air humidity, %
not higher than 90
Design
Detachable plastic body
6
1.3 Factory settings
Terminal’s IP address 175.25.110.71
Terminal’s network address Serial number
Administrator password
No password
1.4 Package contents
Item Number, pcs.
BioSmart PV-WTC Terminal 1
Product certificate 1
Installation instructions 1
Mounting kit (two 6х35 dowels, two
3.5х38 self-tapping screws)
1
2. USE, TRANSPORTATION AND STORAGE CONDITIONS
Abrasive or chemically active materials should not be used to clean the outer surfaces of the device
or the palm vein scanner.
The terminal may be stored in the following environmental conditions:
- ambient air temperature from minus 40 to plus 50 °С;
- relative air humidity (without condensation) up to 98%.
Water, dust and other foreign substances should be prevented from entering the inside of the terminal during transportation and storage. Following storage of the terminal in low temperature or high humidity conditions, it must be kept in a dry environment at a temperature of (20±5) °С for no less than 30 minutes before being turned on.
3. SAFETY REQUIREMENTS
To avoid malfunctions in the terminal, it must be disconnected from its power source before any work is carried out with its case open.
Only specialists authorized by the manufacturers of this terminal should carry out the repair and replacement of terminal parts.
7
4. DISPOSAL
The BioSmart PV-WTC terminal does not contain materials hazardous to the health of users or the environment. No special ecological safety measures are required when disposing of this unit at the end of its operational lifespan.
5. MANUFACTURER’S GUARANTEE
The manufacturer guarantees successful performance and correspondence to the stated product characteristics on the condition that the consumer complies with the rules of its use, installation, connection, transportation and storage.
The manufacturer provides a warranty on the BioSmart PV-WTC terminal for the period of 60 months from the day of sale indicated in its certificate.
If notes on the date of the product’s sale are absent from the certificate, the warranty period is calculated from its manufacturing date.
The Manufacturer’s Warranty does not extend to BioSmart PV-WTC terminals that have broken down due to the Customer failing to comply with its rules of operation.
6. INSPECTION CERTIFICATE
BioSmart PV-WTC- terminal, assembly no. has been classified as fit for use.
Issue date
P r o d u c t i o n M a n a g e r
(signature)
(print full name)
Manufacturer:
GP Systems GmbH
Ochshäuser Str. 45
34123 Kassel Germany
e-mail: info@gp-systems.com
Tel. +49 151 100 41 701
8
7. TERMINAL DESCRIPTION
7.1 Description of terminal’s front panel
An exterior view of the terminal is shown on figure 1.
Figure 1. Exterior view of BioSmart PV-WTC terminal
1. Smart card reader
2. LCD screen
3. Keypad
4. Palm vein scanner
Loading...