PRODUCT CONFIGURATION
OM SERIES MEDIUM CAPACITY HIGH PRESSURE
FLOMEC® OM Medium Capacity High Pressure Flow Meters
provide volumetric measurement of clean liquids for high pressure.
Suitable for applications including metering lubricants, chemicals,
grease, additives, and other high viscosity uids.
FEATURES / BENEFITS
• High accuracy and repeatability, direct volumetric reading
• No requirement for ow conditioning (straight pipe runs)
• Measures both high and low viscosity liquids
• Optional Exd I/IIB approval (ATEX, IECEx)
• High Pressure rated up to 5580 psi (400 bar) (4350 psi [300
bar] on 2 “ meter)
PRODUCT IDENTIFIER
OM
= Oval Gear Meter
METER SIZE
015
= 1/2” (15 mm), 0.26-10.6 GPM (1-40 L/min)
025
= 1” (25 mm), 2.6-40 GPM (10-150 L/min)
040
= 1.5” (40 mm), 4-66 GPM (15-250 L/min)
050 =
BODY MATERIAL
H
= High Pressure 316L SS
(5800 PSI / 400 bar)
(4350 PSI / 300 bar, 050 size)
ROTOR MATERIAL / BEARING TYPE
00 = PPS (Not available for 300ºF (150ºC) meters) / No bearing
10 = Keishi Cut PPS (for high viscosity liquids) (Not available for
300ºF (150ºC) meters) / No bearing
51 = Stainless Steel / Carbon Ceramic
71 = Keishi cut Stainless Steel (for high viscosity liquids) / Carbon
Ceramic
O-RING MATERIAL
1
= Viton™ 5º F minimum (-15º C)
3 = Teon encapsulated Viton™ 5º F minimum (-15º C)
4 = Buna-N (Nitrile), -40º F minimum (-40º C)
MAXIMUM TEMPERATURE LIMIT
-2
= 250º F (120º C) max.
-3+ = 300º F (150º C) max. (Hall Only) (includes SS terminal cover)
-5
= 250º F (120º C) max. (includes integral cooling n)
-8 = 176º F (80º C) max. (meters with integral instruments, OM008
with PPS rotors)
PROCESS CONNECTIONS
1 = BSPP (G) female threaded (ISO 228)
2 = NPT female threaded
CABLE ENTRIES
1
= M20 x 1.5 mm (M16 x 1.5mm for R4 options)
2
= 1/2 “ NPT
6 = 3 x 16 mm drilled holes (for F instruments only)
2
2” (50 mm), 8-130 GPM (30-500 L/min) (PPS rotors)
1 9
3
4
5
6
7
8
INTEGRAL OPTIONS
___ = Combination Reed Switch and Hall Effect Sensor
SS = Stainless steel terminal cover]
RS = Reed Switch only - to suit Intrinsically Safe installations
E1 = Explosion proof Exd IIB T3...T6 [IECEx & ATEX approved]
E2 = Explosion proof Exd I/IIB T3...T6 [IECEx & ATEX mines approved]
R3 = Intrinsically Safe rate totalizer with all outputs (GRN housing)
[IECEx & ATEX approved]*#
R3G = RT12 Intrinsically Safe rate totalizer with all outputs (GRN
Housing) [IECEx & ATEX approved] (with gallons calibration)*#
R4 = RT40 backlit rate totalizer with all outputs (Alloy housing with
facia protector) [scalable pulse output, backlight]*#
R4G = RT40 rate totalizer with backlit large digit LCD (Alloy housings
with facia) (with gallons calibration)*#
R5 = RT14 backlit rate totalizer with all outputs (GRN housing)
[scaled pulse, alarms, 4-20mA, backlight]*#
R5G = RT14 backlit rate totalizer with all outputs (GRN Housing)
(with gallons calibration)*#
E18 = ATEX/IECEx EXd E018 backlit rate/tot, pulse, 4-20mA, lin,
HART (Al), Incl. Line Bushing [IECEx & ATEX approved]#
E19 =ATEX/IECEx EXd E018 backlit rate/tot, pulse, 4-20mA, lin, HART
(SS), Incl. Line Bushing [IECEx & ATEX approved]#
F18 = F018 backlit rate/tot, pulse out, 4-20mA, 10 pt lin, HART#
F19 = F018 Intrinsically Safe backlit rate/tot, pulse out, 4-20mA, 10
pt lin, HART#
F31 = F130 Intrinsically Safe 2 stage batch controller#
1 2 3 4 5 6 7 8 9
--->>>> OM 025 H 00 1 -5 1 1 R5
*Temp code 5 required for integral instruments between 176F (80C) & 250F (120C)
#Temp code 8 required for integral instruments below 176F (80C)
+
Option will de-rate meter pressure ratings by 20%
© 2019 Great Plains Industries, Inc. All Rights Reserved.
SPECIFICATIONS
Nominal Size: 1/2” (15 mm) 1” (25 mm) 1.5” (40 mm) 2” (50 mm)
Nominal Flow* Range @
3cP:
Accuracy:
Repeatability:
Max. Pressure - High
Pressure meter Bar [psi]
(threaded)
Protection Class:
Recommended
Filtration:
Electrical:
Output Pulse Resolution:
Reed Switch: 318 (84) 102 (27) 53 (14) 25 (6.5)
Hall Effect: 636 (168) 405 (107) 212 (56) 99 (26)
High Resolution Hall Effect:
Reed Switch Output:
Hall Effect Output:
OM015 OM025 OM040 OM050
8-118 GPM
0.26-10.6
GPM
(1 - 40 L/min)
± 0.5% of reading (± 0.2% of reading with optional RT14)
IP66/67 (NEMA 4X) optional EX-d I/IIB T4/T6, Integral ancillaries can
636 (168) 204 (54) 106 (28) 49 (13)
30V (dc) x 200mA Max (Maximum thermal shock 18°F [10°C] /min)
3 wire open collector, 5 - 24V (dc) max, 20mA max.
2.6-40
GPM
(10-150 L/min)
Typically ± 0.03% of reading
5800 psi (400 bar)
be supplied with I.S. (Intrinsically Safe)
100 mesh (150 μm)
Pulses / gallon (Pulses / L) - Nominal
4-66
GPM
(15-250 L/min)
(30-450 L/min)
(SS Rotors)
8-130 GPM
(30-500 L/min)
(PPS Rotors)
4350 psi
(300 bar)
APPLICATIONS
• Aviation
• Mining
• Power
• Chemical
• Pharmaceutical
• Food
• Paint
• Petroleum Industries
• Environmental
APPROVALS
DIMENSIONS
All dimensions are ± .079” (±2 mm)
*Maximum ow reduces as viscosity increases,
see ow de-rating guide. Max recommended
Pressure drop is 14.5 psi (1 bar).
OM015H OM025H OM040H OM050H
4.72” (120 mm)
A
4.41” (112 mm) 6.03” (152 mm) 8.54” (217 mm)
B
C
3.62” (92 mm) 3.90” (99 mm) 5.28” (134 mm)
D M10 x 13 M8 x 16
E
1.02” (26 mm) 1.08” (27.5 mm) 1.54” (39 mm)
4.62” (92 mm) 4.41” (112 mm) 6.18” (157 mm
F
RT12 / RT14 RT40
G 2.41” (61 mm) 2.48” (63 mm) 0.51” (13 mm) 1.26” (32 mm)
4.72” (120 mm)
6.30” (160 mm)
M10 x 16
COVER
(N Meters)
7.09” (180 mm)
9.29” (236 mm)
consult distributor for mounting
footprint
2.01” (51 mm)
) 6.77” (172 mm)
COVER
(H & M Meters)
03/19 IND-1043-OM-HIGH PRESSURE-MEDIUM