GPI - Great Plains Industries Flomec Insertion Meters Data Sheet

PRODUCT CONFIGURATION
DP SERIES INSERTION IMPELLER METERS
FLOMEC® Insertion Meters are cost effective stainless steel meters
for measuring the ow of water, fuels and other low viscosity liquids in pipe sizes 1.5” – 100” (10 – 2500 mm). Insertion Meters are a exible, economic method to measure large ow rates with small pressure drops and low installation costs, with most applications battery powered with a FLOMEC
totalizer. Applications include HVAC, hot and cold water, re systems, water distribution (management and treatment), boiler feed water, waste water and hydrant ow testing.
FEATURES / BENEFITS
• IP68 (NEMA6) submersible 316SS construction (cable connection only)
• Intrinsically safe option available
• DP525 version suitable for “hot tap” installations
• Quadrature pulse option available for bi-directional ow measurement
PRODUCT IDENTIFIER
DP = Insertion Meter
METER SIZE
490 = 1.5 to 36” (40-900 mm) 525 = 2 to 100” (50-2500 mm) suitable for “hot-tap” installations
BODY MATERIAL
S = 316 Stainless Steel
2 = PVDF/316 stainless steel (260ºF [120ºC]) 3 = PEEK/tungsten carbide (300ºF [150ºC])
O-RING MATERIAL
1 = Viton™ 5ºF to + 300ºF (-15ºC - + 150ºC) 4 = Buna-N (Nitrile), -40ºF to + 260ºF (-40ºC to + 125ºC)
MAXIMUM TEMPERATURE LIMIT
2 = 260º F (125º C) max. (available with electrical connections 5 & 6) 3 = 300º F (150º C) max. (only available with rotor/shaft type 3,
electrical connection type 5, & Viton O-Ring)
5 = 212º F (100º C) max. (standard temperature rating) 8 = 176º F (80º C) max. (for non-magnetic pick-up type 4)
PROCESS CONNECTIONS
1 = 1-1/2” BSPT male thread (Not available on DP525) 2 = 1-1/2” NPT male thread (Not available on DP525) 3 = 2” BSPT male thread 4 = 2” NPT male thread
PICK-UP TYPE
1 = NPN open collector & voltage pulse (standard) 2 = NPN open collector only 3 = Reed switch only (may be used with an I.S. barrier or instru
ment in hazardous areas)
= Quadrature pulse output (requires F15 option for bi-direc-
9
tional ow capability)
ELECTRICAL CONNECTIONS
= Flying cable (5 ft [1.5 m] on DP490, 3 ft [1 m] on DP525)
C 2 = Flying cable – 33 ft (10 m) 5 = Terminal box on stem kit – IP67 6 = Stem kit ” NPT x M16 thread (required for integral instru
ments)
2
(valve not included)
8
1
3
4
5
6
7
9
INTEGRAL OPTIONS
___ =
= Intrinsically Safe RT12 with all outputs (GRN housing)
R3
[IECEx & ATEX approved]
R3G = RT12 Intrinsically Safe rate totalizer with all outputs (GRN
Housing) [IECEx & ATEX approved] (with gallons calibration)*#
R4 = RT40 backlit rate totalizer (Alloy housing with facia protec-
tor) [scalable pulse output, backlight]
= RT40 rate totalizer with backlit large digit LCD (Alloy
R4G
housings with facia) (with gallons calibration)*#
R5 = RT14 backlit rate totalizer with all outputs (GRN housing)
[scaled pulse, alarms, 4-20mA, backlight]
R5G = RT14 backlit rate totalizer with all outputs (GRN Housing)
(with gallons calibration)*#
F15 = F115 backlit bi-direction ow, rate/tot, pulse out, 4-20mA F18 = F018 backlit rate/tot, pulse out, 4-20mA, 10 pt lin,HART F19 = F018 Intrinsically Safe backlit rate/tot, pulse out, 4-20mA,
10 pt lin, HART^
10
1 2 3 4 5 6 7 8 9 10
--->>>> DP 490 S 2 1 2 -2 1 6 R5G
* Temp code 5 required when operating temperature is between 176º F
(80º C) & 250º F (120º C) # Temp code 8 required for all integral instruments ^Must use pick-up type 3
-
-
© 2017 Great Plains Industries, Inc. All Rights Reserved.
SPECIFICATIONS
Housing Material:
Suits Pipe Sizes
Pipe Connection
Flow Velocity Range
Linearity % of Reading
Temperature Range:
Max. Pressure:
Materials
Protection Class:
Hall Effect
Reed*
Voltage Pulse
Non-Magnetic Sensor
Optional Outputs**
*Reed Switch resolution is 1/3 of the NPN Hall Effect or Voltage Pulse outputs
**Optional Integral option is required
DP490 DP525
1.5 - 35” (40-900 mm) 2 - 100” (50-2500 mm)
1.5” or 2” BSPT or NPT male thread
3 - 33 ft/sec (1 -10 m/s)
Typically ± 1.5%
-40˚F to 300˚F (-40˚C to 150˚C)
1160 psi (80 bar)
316SS body and rotor shaft
IP68 (NEMA 6), optional I.S (Instrinsically Safe)
Intergral options
Pulse Outputs
3 wire open collector, 5-24v (dc), 20mA max. Nom 0
30v (dc), 200mA max. Nom 0 - 80Hz
Self Generated voltage, Nom 0 - 240Hz
3 wire open collector, 5 - 24V (dc), 20mA max.
Nom 0 - 240Hz
4-20mA, scaled pulse, quadrature pulse
2” BSPT or NPT male
thread
-240Hz
Flying Cable Option
A- Thread
A - Dimension
B
C
D
Integral Option
A- Thread
A - Dimension
B
C
D - RT12/RT14
D - RT40
D - F018/F115
E - RT12/RT14
E - RT40
E - F018/F115
F - RT12/RT14
F - RT40
F - F018/F115
DP490 DP525
1.5” or 2” BSP or NPT 2” BSP or NPT
2.36” (60 mm) 2.52” (64 mm)
7.8” (198 mm) 17.48” (444 mm)
1.5” (38 mm) 2.28” (58 mm)
9.33” (237 mm) 16.69” (424 mm)
DP490 DP525
1.5” or 2” BSP or NPT 2” BSP or NPT
2.36” (60 mm) 2.52” (64 mm)
7.8” (198 mm) 17.48” (444 mm)
1.5” (38 mm) 2.28” (58 mm)
16.34” (415 mm) 35.43 in (900 mm)
14.96” (380 mm) 34.06” (865 mm)
16.26” (413 mm) 35.35” (898 mm)
0.47” (122 mm)
4.45” (113 mm)
5.12” (130 mm)
2.40” (61 mm)
2.48” (63 mm)
2.95” (75 mm)
DIMENSIONS
APPLICATIONS
• HVAC
• Hot and Cold Water
• Fire Systems
• Water Distribution (Management and Treatment)
• Boiler Feed Water
• Waste Water
• Hydrant Flow Testing
1/18 IND-1086-DP-SERIES