GPI L5016, L5116, L5132 User Manual

SAVE THIS OWNER’S MANUAL
Oil Pump
Models L 5016, L 5116 & L 5132
Owner’s Manual
DO NOT RETURN THIS
PRODUCT TO THE STORE!
Please contact GPI before returning any product. If you are missing parts or experience problems with your installation, our Customer Support Department will be happy
to assist you:
800-835-0113 or
316-686-7361
TABLE OF CONTENTS
General Information .................................................... 2
Safety Instructions ...................................................... 2
Installation .................................................................. 2
Operation .................................................................... 3
Maintenance ............................................................... 3
Troubleshooting .......................................................... 4
Viscosity Charts .......................................................... 5
Illustrated Parts List .................................................... 6
Specications ............................................................. 7
Service........................................................................ 7
Warranty ..................................................................... 8
To the owner...
Congratulations on receiving your GPI® oil pump. We are pleased to provide you with a system designed to give
you maximum reliability and efciency.
Your pump is designed for use with motor oil, gear oil, hydraulic oil and waste oil. If used with antifreeze, do not exceed 50% water. Please take all due precautions when handling these liquids. Your safety is important to us.
Also, to assure the longest possible service life, it is im­portant that you follow the operation and maintenance procedures outlined in this manual. We are proud to provide you with a quality product and dedicated sup­port. Together with your conscientious use, we are sure that you will obtain years of safe, dependable service.
Victor Lukic, President
Great Plains Industries, Inc.
922029-01 Rev E03/18
GENERAL INFORMATION
The purpose of this manual is to assist you in installing, operating and maintaining your GPI Oil Pump. This pump is a positive displacement, direct drive pump.
Models L 5116 and L 5132 are wired for 115-volts only, however these motors have the capability to run on 230-volts if properly wired by an Electrician (see the label
on the motor for specications). GPI does not supply any
wiring items or hookup connectors for the 230 voltage. Rewiring for 230-volts is the risk and responsibility of the buyer/owner and user. GPI is not liable for any damage or accidents caused by rewiring.
Both the 12-volt DC and the 115-/230-volt AC pump are compatible with motor oil, gear oil, hydraulic oil, antifreeze
(not to exceed 50% water), ATF and waste oil. Do not use this pump for dispensing any uids other than those
for which it was designed. To do so may damage pump components and will void the warranty.
Do not use the GPI Oil pump with water, acids, brake
uid or windshield washer uid.
If in doubt about compatibility of a specic uid, contact the supplier of the uid to check for chemical compat-
ibility with:
Aluminum Stainless Steel
Brass Steel
Nitrile Rubber Zinc Plated Steel
Do not leave the system running without uids. “Dry run­ning” can damage the pump.
Do not pump the tank completely dry, as contaminants from the bottom of the tank may enter the pump.
SAFETY INFORMATION
The following safety alert symbols are used in
this manual.
DANGER
WARNING
CAUTION
DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
WARNING indicates
a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION indicates
a potentially hazardous situation which, if not avoid­ed, may result in minor or moderate injury.
It is your responsibility to:
know and follow applicable national, state and local
safety codes pertaining to installing and operating
electrical equipment for use with petroleum uids.
ensure that all equipment operators have access to
adequate instructions concerning safe operating and maintenance procedures.
Observe all safety precautions concerning safe handling
of petroleum uids. Do not use pump with low ash point uids (100° F or less).
To ensure safe operation, this pump must be properly grounded. Care should be taken to ensure proper ground­ing during initial installation and after any service or repair
procedures. For your safety, please take a moment to
review the warnings below.
Observe precautions against electrical shock when oper­ating the system. Serious or fatal shock can result from operating electrical equipment in damp or wet locations.
On 12-volt pumps, inspect external pump wiring regularly to make sure it is correctly attached to the battery. To avoid electrical shock, use extra care when connecting the pump to power.
WARNING
GPI recommends installing only one pump per battery. Using more than one pump on the same battery could create a hazardous situation in a fault condition. As an option, use an appropriate selector switch that allows only one pump to be run at a time.
Avoid prolonged skin contact with petroleum uids. Use
protective goggles, gloves and aprons in case of splash­ing or spills. Change saturated clothing and wash skin promptly with soap and water.
Observe precautions against electrical shock when servicing the pump. Always disconnect power before repairing or servicing. Never apply electrical power to the system when any of the coverplates are removed.
If using solvent to clean pump components or tank, ob­serve the solvent manufacturer’s recommendations for safe use and disposal.
The 115-/230-volt AC pump motors are equipped with thermal overload protection. If overheated, the pump will shut itself off. Turn off the pump if this occurs. See Motor Protector Section for details.
Worn and damaged hoses or nozzles are potential safety hazards and should be replaced.
INSTALLATION
Make sure all threaded connections are wrapped with three to four turns of oil resistant thread tape or pipe thread sealant.
Make sure drums are properly secured to prevent tip over when full or empty. All tanks must be properly vented.
2
Installing Pump to a Tank
GPI pumps have a 2-inch NPT connection that can be mounted directly to a 2-inch female pipe thread on the tank.
1. Clean the tank interior of all dirt and foreign material.
2. Glue sections of suction pipe together and cut it to the proper length that is required. Suction pipe should extend 2 to 3 inches above bottom of tank.
3. Screw suction pipe into inlet threads of pump base.
4. Insert the suction pipe through the tank bung. Screw pump into tank bung to secure the pump to the tank.
(Figure 1)
FIGURE 1
®
GPI
5. To prevent pressure buildup and possible leaks through the ball valve, make sure the tank is vented.
Installing Discharge Plumbing on Pump Outlet
1. Install a 90 degree elbow to the pump outlet using oil resistant pipe sealant.
2. Install the hose and ball valve using oil resistant pipe sealant on the threads. Tighten securely.
Electrical Installation
WARNING
Electrical wiring must be done by a licensed electrician. Shut off all power before connecting wires to motor. Failure to follow these wiring instructions may result in death or serious injury from shock, re or explosion.
115-/230-volt AC Powered Pumps
(Models L 5116 & L 5132):
This GPI Oil Pump is factory wired for 115-volt AC. These motors have the capability to run on 230-volts if properly wired by an electrician. Power to the unit should be sup­plied from a dedicated circuit breaker.
If AC extension cords are used, they must be capable of
safely carrying the rated motor current. Use only heavy
duty, 3-wire, grounded extension cords.
NOTE: Many building codes require Ground Fault Circuit
interrupt (GFCI) protection.
Motor Ratings (FLA):
115-/230-volt AC: 1/2 HP, 1725 RPM – 7.5/ 3.7 amps 1 HP, 3450 RPM – 13.3/ 6.6 amps
12-volt DC: 1/2 HP, 1800 RPM – 40 amps
12-volt DC Powered Pumps (Model L 5016):
This GPI Oil Pump is factory wired for 12-volt DC. Circuit must be protected with a 50 amp automotive-type fuse
(not supplied).
The power cord is not supplied with the pump. GPI rec­ommends a minimum power cord of 10/3 AWG. Do not exceed 15 feet of cord.
OPERATION
CAUTION
Do not operate pump dry. Damage to pump could occur.
Before rst usage, pour oil into pump outlet port to coat
pumping element.
1. Place ball valve into the receiving tank to be lled.
2. Turn on the motor.
3. Open the ball valve and ll the container to the desired level. If ow does not occur within 15 seconds, shut
off motor and refer to the priming information in the Troubleshooting Section.
4. Shut off the nozzle.
5. Turn off the motor.
Motor Protector
The AC pumps contain thermal motor protection. If the pump overheats the unit will shutoff.
If the motor shuts off, follow these instructions:
Model L 5132: Turn off the switch. Allow the motor to
cool before restarting.
Model L 5116: Turn off the switch. Allow the motor to cool.
Push the button to manually reset the protector.
Model L 5016: The 12-volt model should be protected by
an inline fuse (not supplied). If the motor shuts
off, check the fuse.
MAINTENANCE
Disconnect power and relieve pressure in the system by opening the nozzle before servicing the pump.
This pump is designed for minimum maintenance. Motor bearings are sealed and require no lubrication. Inspect the pump and components regularly for leaks and make sure the hose, ball valve and components are in good condition.
Use of the pump with unauthorized uids will void the
warranty.
Remove and clean the strainer if low ow is noticed.
To clean the strainer, remove the three screws on the strainer cover. Remove cover and pull out screen. Clean screen and reinstall. Care should be taken not to dam­age the O-ring.