GPI GPR-R9H, GPR-G9 Instruction Manual

INSTRUCTION MANUAL
ROTARY LASER LEVEL
GPR-R9H / G9
FOR YOUR RECORD
Place Of Purchase : ....................................
Date Of Purchase : .............../.........../........
- 1 -
Contents
1. Main body........................................................................................ - 2 -
2. Directions......................................................................................... - 6 -
3. Recharge battery ...........................................................................- 11 -
4. Accuracy Checking....................................................................... - 13 -
5. Specifications................................................................................. - 15 -
6. Detector ......................................................................................... - 17 -
7. Remote........................................................................................... - 20 -
- 2 -
1. Main body
Laser Module
Panel
Plug hole
Laser window
Handle
Battery container
- 3 -
1.1 Panel
(3) Right spinning
(3) Left spinning
(7) Setting slope
(5) Angle scanning
(2) Auto/manual
(6) Rotating speed
(1) Power ON/OFF
(4) Anti-drift
- 4 -
1.2 Operation instrument
(1) Power(ON/OFF):Controlling the state of power. (2) Auto/manual: Push button to switch manualRemoteor auto leveling.
(3) Left / right spinning:After the laser head speed is set on 0 r.p.m. the left/right
button can change the laser position.
(4) Anti-drift: The Anti-Drift System, when ON, will signal to the operator that
the instrument has been moved out of level. The ADS LED will blink slowly when instrument in Anti-Drift System. The ADS LED will blink quickly when instrument moved out of level.
(5) Angle scanning:Setting 5 sections angle scanning, 0°-10°-45°-90°-180°, the
Left/right button can change the laser position.
(6) Rotating speed:Setting 5 sections rotating speed, 0-60-120-300-600 r.p.m.
- 5 -
(7) Setting slope (manual mode):The arrow button for upper & down & left &
right can adjust X and Y axis.(Touch panel direction is Y axis)
- 6 -
2. Directions
2.1. Battery Installment
(1) Take down the cover of battery case at the bottom of the instrument. (2) Put the batteries into the case according to the right position. (3) Lay the cover on the box, and then tighten all screws.
2.2 Instrument Placement
2.2.1 Horizontal scanning (manual mode)
Lay the instrument on the tripod or stable flat surface, or even hang it on the wall. Set up right the instrument, and keep the slope of instrument within the range from
-5° to +5°.
2.2.2 Vertical scanning (manual mode)