GPI GPR-R9H, GPR-G9 Instruction Manual

Page 1
INSTRUCTION MANUAL
ROTARY LASER LEVEL
GPR-R9H / G9
Page 2
Page 3
FOR YOUR RECORD
Place Of Purchase : ....................................
Date Of Purchase : .............../.........../........
Page 4
- 1 -
Contents
1. Main body........................................................................................ - 2 -
2. Directions......................................................................................... - 6 -
3. Recharge battery ...........................................................................- 11 -
4. Accuracy Checking....................................................................... - 13 -
5. Specifications................................................................................. - 15 -
6. Detector ......................................................................................... - 17 -
7. Remote........................................................................................... - 20 -
Page 5
- 2 -
1. Main body
Laser Module
Panel
Plug hole
Laser window
Handle
Battery container
Page 6
- 3 -
1.1 Panel
(3) Right spinning
(3) Left spinning
(7) Setting slope
(5) Angle scanning
(2) Auto/manual
(6) Rotating speed
(1) Power ON/OFF
(4) Anti-drift
Page 7
- 4 -
1.2 Operation instrument
(1) Power(ON/OFF):Controlling the state of power. (2) Auto/manual: Push button to switch manualRemoteor auto leveling.
(3) Left / right spinning:After the laser head speed is set on 0 r.p.m. the left/right
button can change the laser position.
(4) Anti-drift: The Anti-Drift System, when ON, will signal to the operator that
the instrument has been moved out of level. The ADS LED will blink slowly when instrument in Anti-Drift System. The ADS LED will blink quickly when instrument moved out of level.
(5) Angle scanning:Setting 5 sections angle scanning, 0°-10°-45°-90°-180°, the
Left/right button can change the laser position.
(6) Rotating speed:Setting 5 sections rotating speed, 0-60-120-300-600 r.p.m.
Page 8
- 5 -
(7) Setting slope (manual mode):The arrow button for upper & down & left &
right can adjust X and Y axis.(Touch panel direction is Y axis)
Page 9
- 6 -
2. Directions
2.1. Battery Installment
(1) Take down the cover of battery case at the bottom of the instrument. (2) Put the batteries into the case according to the right position. (3) Lay the cover on the box, and then tighten all screws.
2.2 Instrument Placement
2.2.1 Horizontal scanning (manual mode)
Lay the instrument on the tripod or stable flat surface, or even hang it on the wall. Set up right the instrument, and keep the slope of instrument within the range from
-5° to +5°.
2.2.2 Vertical scanning (manual mode)
Page 10
- 7 -
Lay the instrument on the flat surface, and keep the slope of instrument within the range from -5° to +5°.
2.3 Operations
2.3.1 Power
(1) Press the key ON/OFF to bring automatic leveling into function when the
power indicator lights.
(2) When power indicator blink, it shows the voltage of the batteries is
insufficient. Then the rechargeable batteries need to be charged.
(3) Press the Key ON/OFF to close down the instrument.
2.3.2 Leveling
(1) When turned on, the laser beam will start to blink, It will stop winking after
Page 11
- 8 -
finish leveling.
(2) If the instrument is placed improperly, or the slope of instrument exceeds the
range from -5° to +5°, the mode indicator and the laser beam will wink at the same time. Then place the instrument properly.
2.3.3 Spinning (1) Change speed
Press the rotating speed button to control the spinning speed of the laser head. If press the key repeatedly, the spinning speed of the laser head will continuously change as follows: 0-60-120-300-600-0 r.p.m.
(2) Stepping spinning
Locate the Key Speeding-up at 0 r.p.m., The laser head will stop spinning. And press the Key Right- spinning, the laser head will step-move clockwise.If
Page 12
- 9 -
then press the key Left-spinning, the laser head will step-move counter-clockwise.
2.3.4 Directional scanning
(1) Press the Key Directional scanning: the laser head will scan directionally. If
press the key repeatedly, the angle of scanning of laser head will continuously changes as follows: 0, -10°, -45°, -90°, -180°, -0°
(2) Press the Key Left-spinning or the key Right-spinning to change the direction
of scanning.
2.3.5 Slope Adjustment
Press the remote Key Manual/Automatic when mode indicator lights, the instrument enters the mode of manual leveling. (1) Slope of X-axis
Page 13
- 10 -
Aim the X1-beam to the direction of the slope required to adjust, as depicted below. Press the key or to move the laser beam up or down.
(2) Slope of Y-axis
Aim the Y1-beam to the direction of the slope required to adjust. Press the key or to move the laser beam up or down.
(3) Press the key Manual/Automatic again
when mode indicator goes out, the instrument will enter mode of automatic leveling.
X1
X2Y1Y2
Page 14
- 11 -
3. Recharge battery
(1) When the batteries needs to be charged, connecting the charger with AC.
Insert the plug of charger into the plug hole at the bottom of the instrument
(As depicted below). (2) If the indicator of charger lights, it shows the batteries are being charged. (3) If the indicator light of the charger winks, it shows the course of recharging
has ended.
Notices:
1. Using the standard rechargeable batteries of the instrument, recharging will be
Plug hole
Charger
Page 15
- 12 -
finished within 7 hours.
2. Power required for the charger: Frequency: 50-60HZ; Voltage: 85-265V.
3. Charging and using of the instrument can progress simultaneously.
4. If keeping the instrument in storage (or Leave the instrument unused for a long
time), the batteries (dry battery or rechargeable battery) needs to be taken out.
5. Brand-new rechargeable batteries or long-time unused rechargeable batteries
need to be recharged and discharged three times to attain the capacity required.
Page 16
- 13 -
4. Accuracy Checking
4.1 Horizontal-surface Checking
(1) Place the instrument at the point of 50m in front of wall (or set a scale plate at
the point of 50m away from the instrument), and then adjust the level of the base approximately to aim the X1 to the wall (or scale plate), as depicted below:
X1
H1
H2
X1-beam
X2-beam
Approximately
Page 17
- 14 -
(2) After switching on the power, use the laser detector measuring the h1 of
X1-beam on the wall or scale plate.
(3) Loose the screw of the tripod, and then turn around the instrument 180° to
measure the h2 of X2-beam on the wall or scale plate. D-value between h1 and h2 ought to be less than 10mm
(4) Check the Y-beam in the same way.
4.2 Horizontal-line Checking
(1) Place the instrument between two walls with the distance of 30m (or two scale
plates with the distance of 30m)
(2) Place the instrument according to horizontal setting and then adjust the
instrument.
Page 18
- 15 -
(3) Switch on the power, and then measure the middle point of the laser beam on
the wall (or scale plate):hA, hB and hA’ , hB’
(4) 1=hA-hA , 2=hB-hB
D-value between 1 and 2 ought to be less than 6mm
hB'
hA'
hB
hA
0.5m
about 30m
about 30m
0.5m
Page 19
- 16 -
5. Specifications
Model no.
GPR-R9H
GPR-G9
Red beam-High power
Green beam
Light source
wavelength 635nm
wavelength 532nm
Leveling accuracy
±10/ ±20
Self-leveling range
±5°
Measuring range
Diameter: 500m (Using the laser detector)
Spinning speed
0,60,120,300,600 r.p.m.
Directional-scanning
0°, 10°, 45°, 90°,180°
Setting slope
±5° (Dual axis)
Down point
Accuracy:±1mm/1.5m
Remote controlling Distance
Approximately 20m
Power Supply
DC 4.8-6V (NI-MH rechargeable)
Working Temperature
-20°C~+50°C (-4°F~+122°F)
Water-proof
IP-56
Dimension
160(L)x160(W)x185(H)mm
Weight
2 kg
Page 20
- 17 -
6. Detector
The Universal Laser Detector aids in locating and targeting a visible or invisible beam emitted by a rotary laser; perfect for use in outdoor conditions, where sunlight and distance may make locating the beam more difficult. The laser detector includes a rod clamp which allows to mount the detector onto square, round or oval sighting rods.
Beam capture
LCD readout window
High Low sensor
Volume ON/OFF
Speaker
Power ON/OFF
Page 21
- 18 -
6.1 Operation instrument
(1) Mount the instrument onto a sighting rod if you are using one. Turn on the
instrument by pressing the ON/OFF pad. The LCD symbols will momentarily flash and the “coarse” beam indicator symbol will remain lit and the audio signal will be on.
(2) Expose the beam capture window of the laser detector towards the direction of
the rotating laser.
(3) Slowly move the laser detector in an upward and downward direction until the
LCD beam indicator arrows appear and/or a pulsing audio signal is heard. Use the Beam Resolution feature to choose between the coarse/low setting, used for approximating level or for initial locating of the center level point, the medium setting, used for greater accuracy, and the fine/high setting, used for
Page 22
- 19 -
the most accurate pinpointing of level. (to see the available Resolutions, please refer to the Specs Table).
(4) Move the detector upward when the low beam indicator light is lit (with
volume on, a short pulsing audio tone is heard). Move the detector downward when the high beam indicator arrow is lit (with volume on, a long pulsing audio tone is heard). When the beam is level, the level beam indicator line will be lit and a solid audio tone will be heard.
(5) If the detector is not struck by a laser beam after 5-8 minutes, the detector will
automatically shut itself off to preserve battery life. Turn the instrument back on using the power button.
Page 23
- 20 -
7. Remote
The remote of the instrument adopts the infrared technique. Aim the aperture of infrared ray to the instrument (as depicted below) to bring remote controlling into function (Available distance: 20M). The tele controlling panel includes 9 keys; the indicator on the device will wink to show the operating signal has been sent out once pressing any key. Functions fulfilled by the remote as follows: (1) Spinning: Operating method referring to 2.3.3. (2) Directional scanning: Operating method referring to 2.3.4. (3) Slope adjustment: Operating method referring to 2.3.5.
Remote
Page 24
Memo
Page 25
Memo
Page 26
Memo
Page 27
Page 28
Giant Precision Instrument Co., Ltd.
No.16, Ln. 134, Liancheng Rd., Zhonghe Dist., New Taipei City 235, Taiwan (R.O.C.)
Zip:23553
Tel: 886-2-2246-7302 Fax: 886-2-2246-7301