GPI GP-1132 Operation Manual

1.
2.
3.
4.
5.
6.
7.
8.
9.
Purpose Safety notice Function and feature Structure of the instrument Operation guideline Self-check of accuracy Technical specification Attachment list Maintenance
Laser Leveled Marker
Operation Manual
To help you use this instrument quickly, we provide a specific operation manual for you. Please read the manual carefully before you use the instrument, and keep it well.
Thanks for choosing and purchasing Laser Marker, the precise instrument. To assure the requirement of preci­sion, please carefully read the manual before you use the instrument, properly keep this instrument for future reference.
Contents
Compact, light-weighted, easy to carry and operate, with accurate marking capacity. Magnetic damping compensator ensures quick automatic leveling. Transmit one level laser beam and one perpendicu- lar laser beam with intersecting as a 90 degrees right angle cross curve, and the perpendicular laser beam can be extended to exceeding the roof. In case of exceeding leveling scope, laser beam of the instrument will automatically flash to give alarm.
Air bubble Switch button(V/H) Battery case Casing(up) Power( lock button of compensator) Leg adjustment screws Junction Plate Casing(down) Level laser beam transmitting window Perpendicular laser beam transmitting window
Open the battery case to insert two sets of 1.5V AA alkaline batteries.(Note the polarity) Properly install the level rotator of the instrument and put it on the elevating tripod support. Properly adjust the leveling. Turn the power and the instrument will be on the automatic leveling condition. Turn the switch button(V/H), level and perpendicu­lar laser beam will be transmitted. In case the laser beam flashes to give alarm, it indicates that the instrument isn’t smoothly positioned and exceeds automatic leveling scope. It is necessary to re-position the instrument and adjust the elevating tripod or leg screws till the water bubble go into the circle. Change the batteries in case the power isn’t sufficient.
1 2 3
The compact instrument Laser Marker is light-weighted, easy to carry and operate, with accurate marking capacity. It is widely applicable to construction and inspection of interior decoration, building installation, piping wiring and various fields requiring marking and positioning.
The laser radiation is strong. Do not look at laser beam directly, avoiding hurting your eyes.
1. Purpose
2. Safety notice
3. Function and Feature
1.
2.
3.
4.
5. Operation guidelines
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
1.
2.
3.
4.
5.
6.
1
2
3
4
5
6
7
8
9
10
4. Structure of the instrument
Air bubble Switch button(V/H) Battery case Casing(up) Power( lock button of compensator) Leg adjustment screws Junction Plate
1.
2.
3.
4.
5.
6.
7.
6. Self-check of accuracy
i. Self-check of level accuracy
Find a smooth wall surface without vibration, which shall be little affected by wind. Mount this instrument five meters away from the wall surface. Properly install the level rotator of the instrument and put it on the elevating tripod support. Properly adjust the leveling. Turn the power and the instrument will be on the automatic leveling condition. Turn the switch button(V/H) to position HV, then two laser beam will display on the wall surface as a cross curve. Assume the intersect as point A, then use right-angle setsquare to measure if the two lines intersect at 90 degrees. Note down point A and point M which is 2.5 meters away from point A at the level line. Rotate the instrument to allow another intersect- point B, which is five meters away from point A. Measure distance E from point M to this level line. E shall be within ±3mm.
At this time, assume a point C on the three meters high perpendicular laser beam. Distance between point A and point C shall be within ±2mm.
4 5
When the instrument is not in used, the power switch shall be turned OFF. Batteries shall be taken out . Put the instrument back into its bag to avoid unexpected damage.
7.
1.
2.
3.
4.
5.
6.
7.
8.
7.
8.
8. Attachment list
Instrument: 1 piece Carrying bag: 1 set Operation Instrument: 1 copy
The instrument is kind of precision instrument which shall not be heated or drenched, extruded by force, collided or fallen for fear of influencing its precision. When not use, power switch shall be pushed to OFF position and batteries shall be taken out after the pilot lamp goes out. Lock the pendulum mass, and put it back into the carrying bag. Keep the instrument clean, use clean and soft cloth to wipe glass of transmitting windows.
1.
2.
3.
9. Maintenance
1.
2.
3.
Find a smooth wall surface without vibration, which shall be little affected by wind. Mount this instru- ment five meters away from the wall surface. Use a thread plumb to determine a perpendicular point B on the ground, which is three meters high from point A, another head of the thread plumb. Turn the power and the instrument will be on the automatic leveling condition. Properly install the level rotator of the instrument and put it on special support. Properly adjust the leveling. Turn the switch button(V/H) to position HV, then two laser beam will display on the wall surface as a cross curve. Coincide the perpendicular laser beam with the perpendicular point B on the ground.
ii. Self-check of perpendicular accuracy
1.
2.
3.
4.
5.
6.
7. Technical specification
Light source: Semiconductor laser instrument Wave Length: 635nm Laser output power: <1mw Level accuracy: at 5m±1.5mm. Perpendicular accuracy: at 5m±1.5mm. Width of laser beam: at 5m±2.5mm Length of laser beam: at 5m>10m Self-leveling range: ±2.5° Brake ways: mechanical ways Operation temperature: -5°C40°C Power supply: two alkaline AA batteries (DV3V) Continuous operation hours with batteries: 12 hours (alkaline batteries) Instrument size: length 98mm*width 60mm*height 105mm
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.