Gp batteries GP60AAS DATASHEET

0 to 45oC
:
Standard Charging
:
Ambient Temperature
60mA maximum current for 1 year
:
Continuous
60mA for 16 hrs at 20
o
C
:
Charging Condition
1.2V:Nominal Voltage
Φ =14.4mm
:
Nominal Dimension
Rechargeable Nickel Cadmium
:
Type
Data Sheet Model No.: GP60AAS
___________________________________________________________________________________________________
14.4
48.2
+0
1800mA
600mA
600mA
300mA
4..7(REF.)
Fast Charge (Charge control required)
Voltage (V)
1.7
1.6
(1C)
1.5
1.4
1.3
300mA
(0.5C)
1.2
1.1 1
0 20 40 60 80 100 120 140 160
Capacity Input ( % )
Low Rate Discharge
Voltage (V)
1.5
1.4
1.3
Charge: 60mA x 16hrs at 20oC
1.2
1.1 1
0.9
0.8
(0.5C)
120mA
(0.2C)
60mA
(0.1C)
0.7
0 2 4 6 8 10 12 14
Discharge Time ( Hrs )
(with Sleeve)
Overcharge
Cylindrical Cell
H =48.2mm Recommended discharge current
:Applications
30 to 1800mA
Minimum: 600mAh
:Capacity
Typical: 660mAh when discharged at 120mA to 1.0V at 20oC
300mA to 600mA (0.5 to 1C)
:Fast Charge
with charge termination control Recommended control parameters:
-V : 10 - 20mV Timer : 120% nominal input
>500 cycles (IEC standard):Service Life
No conspicuous deformation and/or leakage
18.0g:Weight Average 39m upon fully charged
:Internal Resistance
(Range 30-45mΩ) at 1000Hz
1.5V at 60mA charging:Max. Charging Voltage
Range
___
Fast Charging Discharging Storage
+0
-0.7
-1
10 to 45oC
:
-20 to 50oC
:
-20 to 35oC
:
Unit : mm
High Rate Discharge
Voltage (V)
1.5
1.4
Charge: 60mA x 16hrs at 20oC
1.3
1.2
1.1 1
0.9
0.8
(3C)
1200mA
(2C)
(1C)
0.7
0 10 20 30 40 50 60 70
Discharge Time ( Mins )
* The information (subject to change without prior notice) contained in this document is for reference only and should not be used as a basis for product guarantee or warranty. For applications other than those described here, please consult your nearest GP Sales and Marketing Office or Distributors.
Manufacturer reserves the right to alter or amend the design, model and specification without prior notice. CRS3091 Rev.03
Loading...