Gp batteries GP5M60 DATASHEET

Data Sheet Model No.: GP5M60
(with Sleeve)
Overcharge
Range
Rechargeable Nickel Metal Hydride
:Type
Prismatic Cell
:Nominal Dimension
W = 17.0 mm Recommended discharge current
:Applications
55 to 1650mA
1.2V:Nominal Voltage Minimum:550mAh
:Capacity
Typical: 600mAh when discharge at 0.2C to 1.0V at 20oC
55mA for 16hrs at 20oC:Charging Condition 275mA to 550mA (0.5 to 1C)
:Fast Charge
charge termination control recommended control parameters:
-V : 0 - 5mV DT/dt : 0.8oC/min (0.5 to 0.9C) : 0.8 - 1oC/min (1C) TCO : 45 - 50oC Timer : 110% nominal input
>500 cycles (IEC standard):Service Life 55mA maximum current for 7 days
:Continuous
No conspicuous deformation and/or leakage
About 11g:Weight
:Internal Resistance
About 35mΩ upon fully discharged at 1000Hz
1.5V at 55mA charging:Max. Charging Voltage Standard Charging
:Ambient Temperature
L = 35.3 mm T = 6.1 mm ,
0 to 45oC
:
10 to 45oC
:
-20 to 50oC
:
-20 to 35oC
:
Fast Charge (Charge control required)
Voltage (V)
1.6
1.5
1.4
1.3
1.2
1.1 0 20 40 60 80 100 120 140 160
Low Rate Discharge
550mA
(1C)
275mA
(0.5C)
Capacity Input (%)
Voltage (V)
1.5
1.4
Charge: 55mA x 16hrs at 20oC
1.3
1.2
1.1
1.0
0.9
275mA
(0.5C)
110mA
(0.2C)
55mA
(0.1C)
0.8
0.7
0.6 0 2 4 6 8 10 12 14
Discharge Time (Hours)
High Rate Discharge
Voltage (V)
1.5
1.4
Charge: 55mA x 16hrs at 20oC
1.3
1.2
1.1
1.0
0.9
1650mA
(3C)
1100mA
(2C)
0.8
0.7
0.6 0 10 20 30 40 50 60 70
Discharge Time (Mins)
550mA
(1C)
* The information (subject to change without prior notice) contained in this document is for reference only and should not be used as a basis for product guarantee or warranty. For applications other than
Unit : mm
______________________________________________________________________________________________________
Manufacturer reserves the right to alter or amend the design, model and specification without prior notice. SRS9115 Rev.02
those described here, please consult your nearest GP Sales and Marketing Office or Distributors.