Gp batteries GP400LALHT DATASHEET

Type : High Temperature Rechargeable Nickel Metal
Hydride Cylindrical Cell
Nominal Dimension (with Sleeve) Applications : Long term standby use. Recommended
Nominal Voltage : 1.2V Capacity : Nomina l: 4000mAh
Charging Condition : Standard mode:
Service Life : >350 cycles (IEC 61951-2)
Continuous Overcharge Weight : 76g Internal Resistance : Average 12m upon fully charged
Max. Charging Voltage : 1.5V at 400mA charging Ambient Temperature Range
Charge / Discharge efficiency Vs. temp.
120 100
80 60 40 20
Available capacity (%)
0
0 102030405060
Discharge:0.2C until 1.0V
H = 90mm
discharge current: 400mA to 2000mA
Minimum: 4000mAh Typical: 4200mAh When discharged at 800mA to
1.0V at 20
400mA for 16 hrs at 20 Standby Intermittent mode: 400mA for 16hrs at 20 with 400mA for 1min/10mins.
Designed for 10 years standby life, end of life capacity is 60% of nominal capacity at 40deg.C .
: Comply with IEC61951-2
Permanent Charge Endurance Test
(Range 9-15m) at 1000Hz
: Charge:
Discharging: Storage: Storage (1 week):
Charge:0.05C for 48hrs
Charge and discharge temp. (℃)
then maintenance
0 to 50
-20 to 70℃
-20 to 35
-20 to 60
Model No.:
+0
– 1.0
18.3
+0
–1.5
90.0
Low Rate Discharge
1.5
1.4
1.3
1.2
Voltage (V)
1.1 1
0.9
High Rate Discharge
1.5
1.4
1.3
1.2
1.1
Voltage (V)
1
0.9
0.0 0.4 0.8 1.2 1.6 2.0 2.4
Charge:400mA X 16hrs at 20deg.C
800mA 400mA
0123456789101112
Charge:400mA X 16hrs at 20deg.C
The information (subject to change without prior notice) contained in this document is for reference only and should not be used as a basis for product guarantee or warranty. For applications other than those described here, please consult your nearest GP Sales and Marketing Office or Distribut ors .
www.gpbatteries.com.hk
Manufacturer reserves the right to alter or amend the design, model and specification without prior notice. Copyright@GPI International Ltd. – All rights reserved
GP400LALHT
8.5(REF
Discharge Time ( hrs )
2000mA
Discharge Time ( hrs )
.)
PBR073-01 REV00
Loading...