Gp batteries GP380LAHV DATASHEET

Typ e
: Rechargeable Nickel Metal
Model No.: GP380LAHV
Hydride Cylindrical Cell
Nominal Dimension (with Sleeve) Applications
Φ = 18.3mm H = 66.5mm
: Recommended discharge current
380mA to 19A
Nominal Voltage Capacity
: 1.2V : Nominal: 3800mAh
Minimum: 3800mAh Typical: 3990mAh when discharged at 760mA to 1.0V at 20
Charging Condition Fast Charge
380mA for 16 hrs at 20
: 1900mA to 3800mA (0.5 to 1C)
charge termination control recommended control parameters:
-V DT/dt :
: 0-5mV
0.8/min (0.5 to 0.9C)
0.8 - 1/min (1C)
TCO :
45 - 50
Timer : 105% nominal input
(for ref. only)
1900mA (0.5C)
Low Rate Discharge
Voltage (V)
1.5
1.4
1.3
1.2
1.1
1
0.9
0.8 0123456
Charge : 380 mA x 16 hrs at 20
3,800mA
(1C)
1,900mA (0.5C)
Discharge Time (Hrs)
High Rate Discharge
Voltage (V)
1.5
1.4
1.3
1.2
1.1
1
0.9
0.8 0 2 4 6 8 101214161820222426283032
The information (subject to change without prior notice) contained in this document is for reference only and should not be used as a basis for product guarantee or warranty. For applications other than those described here, please consult your nearest GP Sales and Marketing Office or Distributors.
Charge : 380mA x 16hrs at 201C
Discharge Time (Mins)
Service Life Continuous Overcharge
Weight Internal Resistance
Max. Charging Voltage Ambient Temperature Range
Fast Charge (Charge Control required)
Voltage (V)
1.6
1.5
1.4
1.3
1.2
1.1
1.0 0 20 40 60 80 100 120 140
: >500 cycles (IEC standard) : 380mA maximum current for 1 year.
No conspicuous deformation and/or
Leakage : 60.0g :
Average 7m upon fully charged
(Range 5-10m) at 1000Hz : 1.5V at 380mA charging :
Standard Charge : 0 to 40
Fast Charging : 10 to 40
Discharge : -20 to 50
Storage : -20 to 35
Storage (1week) : -20 to 60
3800mA (1C)
Capacity Input (%)
www.gpbatteries.com.hk
Manufacturer reserves the right to alter or amend the design, model and specification without prior notice. Copyright@GPI International Ltd. – All rights reserved
19A (5C)
1
C
760mA
(0.2C)
11.4A (3C)
7.6A (2C)
ZRS5062 rev.00