Data Sheet Model No.: GP370SCHR
Rechargeable Nickel Metal Hydride
:Type
(with Sleeve)
Overcharge
Voltage
Range
Cylindrical Cell
:Nominal Dimension
∅ = 23.0mm
H = 43.0mm
Discharge current
:Application
3.6A to 30A (Continuous)
1.2V:Nominal Voltage
Nominal : 3600mAh
:Capacity
Minimum : 3400mAh
Typical : 3700mAh
when discharged at 30A to 0.8V at 20
360mA for 16 hrs at 20
:Fast Charge
1.8A to 6A with charge
o
C:Charging Condition
termination control.
Recommended control parameter :
0-5mV
-∆V
dT/dt
TCO
Timer
:
o
0.8
:
C/min (0.5C to 0.9C)
o
0.8-1
C/min (>1C)
o
40-45
:
:
C
105% nominal input
(Secondary)
> 500 cycles (IEC standard):Service Life
360mA maximum current for a year
:Continuous
No conspicuous deformation and/or leakage
64.5g:Weight
:Internal Resistance
Average 3mΩ upon fully charged
(Range : 2-4mΩ) at 1000Hz
1.5V at 360mA charging:Max. Charging
:Ambient Temperature
Standard Charging
Fast Charging
Discharging
Storage
Storage (1 week)
:
:
:
:
:
0oC to 40oC
o
10
C to 40oC
o
-20
C to 50oC
o
-20
C to 35oC
o
-20
C to 60oC
o
C
Fast Charge (Charge Control required)
Voltage (V)
1.6
1.5
1.4
1.3
1.2
1.1
1.0
0 20 40 60 80 100 120
3600 mA (1C)
1800 mA
(0.5C)
Capacity Input (%)
High Rate Discharge
Voltage (V)
1.5
1.4
1.3
1.2
1.1
1
0.9
0.8
0 2 4 6 8 101214161820222426283032
MPV (V)
1.25
Charge : 360 mA x 16 hrs at 20
30A
18A
(5C)
Discharge Time (Mins)
10.8A
(3C)
1
C
7.2A
(2C)
140
1.2
+ 0
- 1.0
φ
10.0 (Ref.)
23.0mm
φ
1.15
1.1
1.05
1C 5C 10C
- 1.0
+ 0.5
* The information (subject to change without
Discharge rate
prior notice) contained in this document is for
43.0mm
unit : mm
reference only and should not be used as a basis
for product guarantee or warranty. For
application other than those described here,
pleaseconsult GP Sales and Marketing Officeor
Distributors.
Manufacturer reserves the right to alter or amend the design, model and specification without prior notice. ZRS5037 Rev.01