Gp batteries GP130AFHR DATASHEET

Typ e
g
)
)
)
Nominal Dimension (with Sleeve) Applications
Nominal Voltage Capacity
Charging Condition Fast Charge
Service Life
Continuous Overcharge
Weight Internal Resistance
Max. Charging Voltage Ambient Temperature Range
Hydride Cylindrical Cell
:
) = 17.0mm H = 28.5mm
: Recommended discharge current
120mA to 15A(continuous) : 1.2V : Nominal: 1200mAh
Minimum: 1200mAh
Typical: 1250mAh
When discharged at 1200mA to
1.0V at 20к
:
120mA for 16 hrs at 20к : 600mA to 1200mA (0.5 to 1C)
with charge termination control
recommended control parameters:
-'V DT/dt :
: 0-5mV
0.8к/min (0.5 to 0.9C)
0.8 - 1к/min (1C)
TCO :
40 - 45к
Timer : 105% nominal input
(for ref. only)
: >500 cycles (IEC61951-2)
: 120mA maximum current for 1 year.
No conspicuous deformation and/or
leakage : 23.90g :
Average 5m: upon fully charged
(Range 4 – 9m:) at 1000Hz : 1.5V at 120mA charging :
Standard Charge : 0 to 40к
Fast Charging : 10 to 40к
Discharge : -20 to 50к
Storage : -20 to 35к
Storage(1week) : -20 to 60к
Model No.: GP130AFHR
+0
17.0 –0.7
+0
28.5 -1.5
Voltage (V)
Fast Charge(charge control required
Voltage(V)
1.6
1.5
1.4
1.3
1.2
1.1
1
1200mA (1C)
600mA (0.5C)
0 20406080100120140160
Capacity input (%)
8.0 (Ref.)
Unit:mm
1.5
1.4
Charge: 120mA X 16hrs at 20к
1.3
1.2
1.1
oltage(V)
1
15A
0.9
0.8 0 2 4 6 8 10121416182022 2426283032
6.0A (5C
3.6A(3C)
Discharge Time (mins)
High rate discharge
2.4A (2C)
MPV(V
1.275
1.25
1.225
1.2
1.175
1.15
The information (subject to change without prior notice) contained in this document is for reference only and should not be used as a basis for product guarantee or warranty. For applications other than those described here, please consult your nearest GP Sales and Marketing Office or Distributors.
www.gpbatteries.com.hk
Manufacturer reserves the right to alter or amend the design, model and specification without prior notice. Copyright@GPI International Ltd. – All rights reserved
Hi
h rate discharge
1C 5C 10C
Discharge rate
ZRS5049 rev.01
Loading...