Gp batteries GP110AAHT DATASHEET

(
)
Type
Nominal Dimension (with Sleeve)
Applications
Nominal Voltage Nominal Capacity
Charging Condition
: High Temperature Rechargeable Nickel Metal
Hydride Cylindrical Cell
Φ = 14.4mm H = 48.2mm
: Long term standby use. Recommended
discharge current : 110mA to 550mA : 1.2V : Minimum: 1100mAh
Typical: 1155mAh
When discharged at 220mA to
1.0V at 20
: Standard mode :
110mA for 16 hrs at 20
Standby Intermittent model:
110mA for 16hrs at 20
. then maintenance
Model No.: GP110AAHT
+0
14.4 – 0.7
6.5(REF.)
+0
48.2 –1.5
Service Life
Continuous Overcharge Weight Internal Resistance
Max. Charging Voltage Ambient Temperature Range
with 110mA for 1min/ 10mins. : >350 cycles (IEC 61951-2)
Designed for a 10 years standby life, end
of life capacity is 60% of nominal capacity . : Comply with IEC61951-2
Permanent Charge Endurance Test : 21.5g :
Average 23m upon fully charged
(Range 18 - 28m) at 1000Hz : 1.5V at 110mA charging : Charge :
Discharging :
Storage :
Storage ( 1 week ) :
-20 to 40
-20 to 35
-20 to 60
0 to 40
℃ ℃ ℃
Low Rate Dischar ge
Voltage (V)
1.5
1.4
1.3
1.2
1.1 1
0.9
0.8
01234567891011
Charge / discharge efficiency vs. temp.
Charge / Discharge efficiency Vs. temp.
Available Capacity (%)
120 100
80 60 40
Charge: 110mA X 16hrs at 20
550mA
(0.5C)
220mA
0.2C
Discharge time (hrs)
Disch at 0.2C to 1V cut-off
Charge: 0.05C for 48hrs
after charge 0.05C x 48 hrs
Discharge: 0.2C until 1.0V
110mA
(0.1C
)
20
0
0 1020304050607080
Charge and discharge temp. (degC)
The information (subject to change without prior notice) contained in this document is for reference only and should not be used as a basis for product guarantee or warranty. For applications other than those described here, please consult your nearest GP Sales and Marketing Office or Distributors.
www.gpbatteries.com.hk
Manufacturer reserves the right to alter or amend the design, model and specification without prior notice. Copyright@GPI International Ltd. – All rights reserved
ZRS5007 rev.00
Loading...