Gp batteries CP211AFH DATASHEET

1.5V at 210mA charging
:
Max. Charging Voltage
Average 17m
upon fully charged
:
Internal Resistance
>500 cycles (IEC standard)
:
Service Life
1050mA to 2100mA (0.5 to 1C)
:
Fast Charge
Minimum: 2100mAh
:
Capacity
Φ =17.0mm
:
Nominal Dimension
Rechargeable Nickel Metal Hydride
:
Type
Data Sheet Model No.: GP211AFH
___________________________________________________________________________________________________
Discharge Time (Hrs)
17.0 43.0
+0
6300mA
(3C)
(1C)
1050mA
1050mA
6.7(REF.)
Fast Charge (Charge control required)
Voltage (V)
1.6
1.5
1.4
1.3
2100mA
(0.5C)
(with Sleeve)
Cylindrical Cell
H =43.0mm Recommended discharge current
:Applications
210 to 6300mA
1.2V:Nominal Voltage
Overcharge
Range
Typical: 2160mAh When discharged at 420mA to 1.0V at 20oC
210mA for 16 hrs at 20oC:Charging Condition
charge termination control recommended control parameters:
-V : 0 - 5mV DT/dt : 0.8oC/min (0.5 to 0.9C) : 0.8 - 1oC/min (1C) TCO : 45 - 50oC Timer : 105% nominal input
210mA maximum current for 1 year
:Continuous
No conspicuous deformation and/or leakage
32.0g:Weight
(Range 15-25mΩ) at 1000Hz
0 to 45oC
Standard Charging
:Ambient Temperature
+0
-0.7
:
10 to 45oC
:
-20 to 50oC
:
-20 to 35oC
:
1.2
1.1 0 20 40 60 80 100 120 140 160
Capacity Input ( % )
Low Rate Discharge
Voltage (V)
1.5
1.4
1.3
Charge: 210mA x 16hrs at 20oC
1.2
1.1
1
0.9
0.8
(0.5C)
420mA
(0.2C)
210mA
(0.1C)
0.7 0 2 4 6 8 10 12
High Rate Discharge
1.5
1.4
1.3
Charge: 210mA x 16hrs at 20oC
1.2
1.1
1
0.9
0.8
0.7 0 10 20 30 40 50 60 70
4200mA
(2C)
2100mA
(1C)
-1
* The information (subject to change without prior notice) contained in this document is for reference only and should not be used as a basis for product
Unit : mm
guarantee or warranty. For applications other than those described here, please consult your nearest GP Sales and Marketing Office or Distributors.
___
Manufacturer reserves the right to alter or amend the design, model and specification without prior notice. CRS3447 Rev.04